{"product_id":"cc-pdod51-honeywell-i-o-termination-assembly","title":"CC-PDOD51 | Honeywell |  I\/O Termination Assembly","description":"\u003ch2\u003eHoneywell CC-TDOD51 I\/O Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for field termination of 24 VDC digital output signals in Honeywell Series C I\/O system, the \u003cstrong\u003eHoneywell CC-TDOD51\u003c\/strong\u003e (\u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e I\/O Termination Assembly) provides direct physical\/electrical execution for routing 32-channel open-drain output interfaces between Series C I\/O modules and field wiring terminals.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo official public suffix decomposition or functional variant matrix is defined for CC-TDOD51 \/ CC-PDOD51. The model is treated as a fixed-order termination assembly tied to Series C digital output architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDOD51 \/ CC-PDOD51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eField-powered via I\/O module backplane \/ external field supply (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSINK (Open Drain)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1000 VAC RMS system-to-field galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On\/Off Time\u003c\/td\u003e\n\u003ctd\u003e10 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e100 µA max (off-state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Series C Field I\/O Termination Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CC-TDOD51 assembly interfaces with Honeywell Series C digital output modules through a fixed I\/O termination structure supporting channel-level field wiring distribution. The design implements system-to-field galvanic isolation rated at 1000 VAC RMS, separating backplane logic from external 24 VDC field circuits.\u003c\/p\u003e\n\u003cp\u003eChannel architecture is configured for open-drain sink operation, requiring external field power distribution. Off-state behavior maintains nominal 24 VDC potential with leakage current limitation defined at microampere level. Output switching is non-redundant with direct channel mapping to module logic states without intermediate buffering.\u003c\/p\u003e\n\u003cp\u003eSignal routing is optimized for high-density termination of discrete control signals such as solenoid actuation, relay driving, and discrete load switching within Series C I\/O racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does CC-TDOD51 support hot-swap during active channel operation?\u003cbr\u003eA: Hot-swap behavior is dependent on the Series C chassis and controller configuration. Field termination removal may cause transient loss of all 32 channels due to shared termination bus architecture.\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane impact on load switching?\u003cbr\u003eA: The termination assembly itself does not process load current. Switching current is handled entirely at the field side; backplane signals remain low-level logic without load participation.\u003c\/p\u003e\n\u003cp\u003eQ: Can CC-TDOD51 be used in redundant I\/O configurations?\u003cbr\u003eA: This model is defined as non-redundant termination hardware. Redundancy, if implemented, is handled at module or controller level, not at termination assembly level.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eField wiring shall be routed to terminal points with maintained separation between field power and signal conductors. Shield termination should follow single-point grounding practice at cabinet earth reference to minimize ground loop formation.\u003c\/p\u003e\n\u003cp\u003eEnsure all 24 VDC field supplies are externally fused according to per-channel current limits. Channel wiring should avoid parallel routing with high-noise AC conductors or inverter output lines.\u003c\/p\u003e\n\u003cp\u003eTermination seating into the Series C backplane interface must be fully engaged to maintain isolation barrier integrity and channel continuity.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44306827968600,"sku":"CC-PDOD51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-PDOD51-3.jpg?v=1782982544","url":"https:\/\/www.industriaxplc.com\/id\/products\/cc-pdod51-honeywell-i-o-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}