{"product_id":"cc-gdil11-digital-input-module-honeywell","title":"CC-GDIL11 | Digital Input Module | Honeywell","description":"\u003ch2\u003eHoneywell CC-GDIL11 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in a Honeywell control system, the \u003cstrong\u003eHoneywell CC-GDIL11\u003c\/strong\u003e (\u003cstrong\u003eCC-GDIL11\u003c\/strong\u003e Digital Input Module) provides direct electrical input processing. The module accepts 32 digital input channels with optical isolation between field and system circuitry, supporting DC input sensing through defined voltage and current thresholds.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe available information identifies \u003cstrong\u003eCC-GDIL11\u003c\/strong\u003e as a single catalog model. No official suffix variants or ordering matrix are specified in the provided documentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-GDIL11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS or +\/- 1500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Technique\u003c\/td\u003e\n\u003ctd\u003eOptical (in IOM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDI Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Sense Voltage\u003c\/td\u003e\n\u003ctd\u003e13 VDC minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Sense Current\u003c\/td\u003e\n\u003ctd\u003e3 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Sense Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Sense Current\u003c\/td\u003e\n\u003ctd\u003e1.2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e4.2 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter and Isolation Delay\u003c\/td\u003e\n\u003ctd\u003e5 ms +\/- 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Resistance for Guaranteed ON\u003c\/td\u003e\n\u003ctd\u003e300 Ohm maximum at 15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1 cm x 18.8 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CC-GDIL11 employs optical isolation within the input module architecture to separate field wiring from the controller interface. The specified isolation rating of 1500 VAC RMS or +\/- 1500 VDC reduces electrical coupling between external field circuits and the internal electronics.\u003c\/p\u003e\n\u003cp\u003eEach input channel operates from an 18 to 30 VDC field supply and evaluates discrete states using defined voltage and current thresholds. The specified 5 ms input filtering delay assists in rejecting short-duration transient signals before logic state transfer to the control system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CC-GDIL11 support hot replacement while the controller is energized?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The provided specification does not define hot-swap capability. Module replacement should follow the installation and maintenance procedures specified for the target Honeywell control platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the ON state determined for each digital input?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e A guaranteed ON condition requires at least 13 VDC or 3 mA at the input. The connected field circuit should also maintain a maximum field resistance of 300 Ohm at 15 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the specified 5 ms input delay?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The delay represents the combined effect of the input filter and optical isolation circuitry, reducing the influence of short electrical disturbances before the signal is processed by the control system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the external field supply remains within the specified 18 to 30 VDC operating range before energizing the module.\u003c\/li\u003e\n\u003cli\u003eSeparate digital input wiring from high-current motor and power cables to reduce conducted electrical noise.\u003c\/li\u003e\n\u003cli\u003eFollow the control system grounding practice and terminate cable shields according to the cabinet grounding specification.\u003c\/li\u003e\n\u003cli\u003eConfirm field resistance and input voltage at the terminal block when commissioning discrete input devices.\u003c\/li\u003e\n\u003cli\u003eDe-energize field wiring before connecting or disconnecting terminal conductors unless the installed system documentation explicitly permits live maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44301235257432,"sku":"CC-GDIL11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-GDIL11-3.jpg?v=1782891440","url":"https:\/\/www.industriaxplc.com\/id\/products\/cc-gdil11-digital-input-module-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}