{"product_id":"bently-nevada-990-04-50-01-00-vibration-transmitter-1","title":"Bently Nevada 990-04-50-01-00 Vibration Transmitter","description":"\u003ch2\u003eBently Nevada 990-04-50-01-00 Vibration Transmitter\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-04-50-01-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e990-04\u003c\/strong\u003e Vibration Transmitter, operates as a dedicated hardware component for vibration signal conversion and mechanical condition monitoring within Bently Nevada vibration monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-04-50-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10 x 7.5 x 5.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCurrent output limitation: 23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e0-4 mils pp (0-100 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Interface\u003c\/td\u003e\n\u003ctd\u003eVibration measurement signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Measurement and Mechanical Vibration Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-50-01-00 transmitter processes vibration input signals from compatible eddy-current proximity measurement systems and converts mechanical shaft displacement data into proportional electrical output signals. Moreover, the module maintains measurement scaling based on the selected full-scale range of 0-4 mils pp (0-100 um pp).\u003c\/p\u003e\n\u003cp\u003eThe transmitter supports vibration monitoring applications where rotor displacement information requires conversion into an industrial monitoring signal. Therefore, proper probe configuration, cable routing, and signal grounding directly influence measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eThe Bently Nevada vibration monitoring architecture uses eddy-current probe scaling methods and gap voltage validation principles for mechanical condition analysis. In addition, the probe system typically references gap voltage targets around -10 VDC to confirm correct probe operating position and measurement range.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What vibration measurement range does the 990-04-50-01-00 support?\u003cbr\u003eA: The configured full-scale measurement option is 0-4 mils pp (0-100 um pp).\u003c\/p\u003e\n\u003cp\u003eQ: What mounting method does this vibration transmitter use?\u003cbr\u003eA: The unit uses 35 mm DIN rail clips for mechanical installation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the transmitter provide current limiting protection?\u003cbr\u003eA: Yes. The output circuit includes current limiting with a typical value of 23 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 990-04-50-01-00 on a suitable 35 mm DIN rail mounting structure and verify mechanical fixation before connecting field wiring.\u003c\/p\u003e\n\u003cp\u003eUse shielded signal cables where required by the monitoring system design. Connect cable shields according to the plant grounding standard to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eRoute vibration signal wiring separately from high-voltage power cables and switching circuits. In addition, confirm proximity probe wiring polarity, cable continuity, and terminal identification before system commissioning.\u003c\/p\u003e\n\u003cp\u003eVerify the configured system length option of 5.0 metres (16.4 feet) matches the connected probe extension arrangement. Perform signal validation after installation to confirm correct vibration measurement behavior.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44350062428248,"sku":"990-04-50-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/990-04-50-01-00-3.jpg?v=1783587677","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-990-04-50-01-00-vibration-transmitter-1","provider":"IndustriaX Limited","version":"1.0","type":"link"}