{"product_id":"bently-nevada-82362-01-3300-20-dual-thrust-position-monitor-module","title":"Bently Nevada 82362-01 3300\/20 Dual Thrust Position Monitor Module","description":"\u003ch2\u003eBently Nevada 82362-01 3300\/20 Dual Thrust Position Monitor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 82362-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e82362-01\u003c\/strong\u003e Dual Thrust Position Monitor Module, operates as a dedicated hardware component for axial shaft displacement monitoring within the Bently Nevada 3300\/03 Machinery Protection System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%; height: 470.455px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 25.6744%; height: 19.6023px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 71.3299%; height: 19.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003e82362-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eDual Thrust Position Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003e3300\/20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 39.2045px;\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 39.2045px;\"\u003eBently Nevada 3300\/03 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 39.2045px;\"\u003eMonitoring Function\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 39.2045px;\"\u003eDual-channel axial thrust position measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eInput Type\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eEddy-current proximity probe signal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 39.2045px;\"\u003eCompatible Transducer\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 39.2045px;\"\u003e3300 XL Proximity Probes and 7200 Series 14 mm HTPS Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003e+\/- 25 mils (25-0-25 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eInput Sensitivity\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003e100 mV\/mil (3.94 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eProportional analog voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eAlarm Function\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eIntegral Alert\/Danger alarm relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eIndependent electrical isolation between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eSupplied through 3300 system rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eApprox. 241 x 24 x 99 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 19.6023px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 19.6023px;\"\u003eApprox. 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.6744%; height: 39.2045px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 71.3299%; height: 39.2045px;\"\u003eSupplied by 3300 rack internal power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe 82362-01 module processes displacement signals generated by eddy-current proximity probe systems. The module applies probe scaling characteristics to convert gap variations between the probe tip and rotor surface into proportional electrical displacement values.\u003c\/p\u003e\n\u003cp\u003eThe monitoring circuit evaluates axial rotor movement relative to the thrust bearing position. Signal conditioning is configured for thrust position applications, including gap voltage validation and stable measurement behavior within the proximity transducer operating range. The module architecture supports rotor dynamics analysis by providing continuous axial position feedback for machinery protection logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of transducer input is supported by the 82362-01 module?\u003cbr\u003eA: The module accepts eddy-current proximity probe signals from compatible Bently Nevada proximity systems, including 3300 XL and 7200 series Proximitor configurations.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 82362-01 provide independent monitoring channels?\u003cbr\u003eA: Yes. The module contains two independent thrust position monitoring channels with separate signal paths and electrical isolation.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 82362-01 installed as a standalone device?\u003cbr\u003eA: No. The module is installed within the Bently Nevada 3300 rack system and receives operating power through the system backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module only in the designated 3300 system rack slot and verify rack power compatibility before insertion.\u003c\/li\u003e\n\u003cli\u003eConnect proximity probe wiring using shielded instrumentation cable suitable for low-level displacement signals.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between probe signal wiring and high-current power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eGround cable shields according to site instrumentation grounding practices and avoid creating unintended ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify probe gap voltage and signal polarity before commissioning the thrust position monitoring channel.\u003c\/li\u003e\n\u003cli\u003eConfirm alarm relay wiring and external shutdown logic connections before placing the protection system into service.\u003c\/li\u003e\n\u003cli\u003eFollow Bently Nevada 3300 system installation procedures for rack configuration, module addressing, and maintenance access.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44341368324184,"sku":"82362-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/82362-01-3.jpg?v=1783419762","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-82362-01-3300-20-dual-thrust-position-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}