{"product_id":"bently-nevada-79512-01-3300-series-temperature-monitor-input-module","title":"Bently Nevada 79512-01 3300 Series Temperature Monitor Input Module","description":"\u003ch2\u003eBently Nevada 79512-01 3300 Series Temperature Monitor Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi-channel temperature signal acquisition in the Bently Nevada 3300 Series rack system, the \u003cstrong\u003eBently Nevada 79512-01\u003c\/strong\u003e (\u003cstrong\u003e79512-01\u003c\/strong\u003e 6-Channel Temperature Monitor Input Module) provides direct electrical processing of thermocouple and RTD measurement signals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e79512-01 \/ PWA 79512-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e6-Channel Temperature Monitor Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 Series Rack System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eTemperature signal acquisition and monitoring for 3300\/30 and 3300\/35 temperature monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Quantity\u003c\/td\u003e\n\u003ctd\u003e6 independent isolated input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Input Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple (TC) and RTD, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouples\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, N, R, S, B, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conditioning\u003c\/td\u003e\n\u003ctd\u003eIntegrated cold junction compensation (CJC) for thermocouple measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eHigh impedance input design for EMI\/RFI noise reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eSensor dependent, typical range from -200 deg C to +1800 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% of full scale or +\/-1 deg C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Interface\u003c\/td\u003e\n\u003ctd\u003e3300 rack backplane data communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 1-5 VDC output, configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eSupplied through 3300 rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 3300 rack slot installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied by rack backplane, value dependent on system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Temperature Signal Processing and TSI Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 79512-01 processes temperature measurement signals within the 3300 Series machinery protection architecture. It converts thermocouple or RTD inputs into monitored temperature values for alarm handling, recorder outputs, and system data processing.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module supports machinery condition monitoring applications where thermal behavior affects rotor dynamics. Temperature variations from bearings, housings, and rotating assemblies can be evaluated together with vibration and position measurements to support TSI-related analysis.\u003c\/p\u003e\n\u003cp\u003eThe input design incorporates signal conditioning methods to reduce measurement interference. Therefore, the isolated channels maintain separation between multiple temperature sensors installed on the same machine train.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the Bently Nevada 79512-01 support both thermocouple and RTD inputs?\u003cbr\u003eA: Yes. The module supports thermocouple and RTD measurement inputs depending on the configured module option and system setup.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 79512-01 powered through an external power supply?\u003cbr\u003eA: No. The module receives operating power from the Bently Nevada 3300 Series rack backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module provide direct communication with external control systems?\u003cbr\u003eA: The module transfers processed temperature data through the 3300 rack system. External outputs depend on the installed monitoring configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 79512-01 module in the designated slot of the Bently Nevada 3300 rack chassis. Verify rack power isolation before inserting or removing the module.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation cables for thermocouple and RTD wiring. Connect cable shields according to site grounding practices to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eSeparate temperature signal wiring from high-current motor cables, power conductors, and switching circuits. Maintain correct sensor polarity during thermocouple installation because reversed connections can produce incorrect temperature readings.\u003c\/p\u003e\n\u003cp\u003eConfirm the sensor type configuration before commissioning. Verify cold junction compensation operation for thermocouple applications and check channel status through the connected 3300 monitoring system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44402568855640,"sku":"79512-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/PWA79512-01-3.jpg?v=1784527731","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-79512-01-3300-series-temperature-monitor-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}