{"product_id":"bently-nevada-350500-00-00-00-01-01-dynamic-pressure-charge-amplifier","title":"Bently Nevada 350500-00-00-00-01-01 Dynamic Pressure Charge Amplifier","description":"\u003ch2\u003eBently Nevada 350500-00-00-00-01-01 Dynamic Pressure Charge Amplifier\u003c\/h2\u003e\n\u003cp\u003eConfigured for dynamic pressure signal conditioning in Bently Nevada machinery monitoring platforms, the \u003cstrong\u003eBently Nevada 350500-00-00-00-01-01\u003c\/strong\u003e (\u003cstrong\u003e350500\u003c\/strong\u003e Dynamic Pressure Charge Amplifier) provides direct physical signal conversion from piezoelectric pressure sensor charge output to low-impedance voltage transmission.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e350500-00-00-00-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting enclosure; exact dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial installation environment; calibration reference at 23 deg C +\/- 2 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered by -24 VDC supply; exact consumption not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDynamic Pressure Charge Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eHigh-impedance piezoelectric sensor charge signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e16 pC\/psi (232 pC\/bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eLow-impedance voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/psi (1.45 V\/bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C Class I Division 2 Groups A, B, C, D; ATEX\/IECEx Zone 2 when installed in approved enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003eCompatible with Bently Nevada dynamic pressure monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy Current and Rotor Dynamics Signal Integration\u003c\/h3\u003e\n\u003cp\u003eThe 350500 Dynamic Pressure Charge Amplifier processes piezoelectric sensor charge signals before connection to vibration and combustion monitoring systems. Moreover, the module applies charge-to-voltage conversion to maintain signal integrity when sensor outputs require extended field transmission distances.\u003c\/p\u003e\n\u003cp\u003eThe device operates within Bently Nevada machinery monitoring architectures where signal scaling and measurement validation are required. In addition, the signal conditioning approach supports integration with systems such as the Bently Nevada 3500\/64 Dynamic Pressure Monitor and Orbit 60 platforms.\u003c\/p\u003e\n\u003cp\u003eThe module design follows Bently Nevada mechanical monitoring principles, including controlled signal scaling and interference reduction practices used in rotating equipment applications. Therefore, the charge amplifier helps maintain accurate dynamic pressure measurement data for rotor-related analysis and combustion pressure monitoring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of sensor signal does the Bently Nevada 350500-00-00-00-01-01 accept?\u003cbr\u003eA: The module accepts high-impedance charge output signals from piezoelectric dynamic pressure sensors and converts them into low-impedance voltage signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 350500-00-00-00-01-01 connect directly to standard vibration probes?\u003cbr\u003eA: No. The unit is designed for dynamic pressure charge sensors and is not an eddy-current proximity probe interface.\u003c\/p\u003e\n\u003cp\u003eQ: What installation consideration applies to hazardous area operation?\u003cbr\u003eA: Hazardous area installations require compliance with the applicable CSA, ATEX, or IECEx enclosure and installation requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a standard 35 mm DIN rail inside an approved control cabinet or junction enclosure.\u003c\/li\u003e\n\u003cli\u003eUse shielded signal wiring between the piezoelectric pressure sensor and the charge amplifier input.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to site grounding practices to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eSeparate dynamic pressure signal cables from high-current power wiring and switching circuits.\u003c\/li\u003e\n\u003cli\u003eVerify the -24 VDC supply polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eConfirm sensor sensitivity settings match the configured 16 pC\/psi input scaling before commissioning.\u003c\/li\u003e\n\u003cli\u003eInspect connector seating and cable routing before performing signal validation tests.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44372342636632,"sku":"350500-00-00-00-01-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350500-00-00-00-01-01-3.jpg?v=1783938898","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-350500-00-00-00-01-01-dynamic-pressure-charge-amplifier","provider":"IndustriaX Limited","version":"1.0","type":"link"}