{"product_id":"bently-nevada-3500-25-01-01-00-keyphasor-module","title":"Bently Nevada 3500\/25-01-01-00 Keyphasor Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 3500\/25-01-01-00 Keyphasor Module\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/25-01-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25 Keyphasor module\u003c\/strong\u003e, serves as the primary single-channel phase reference module utilized to execute shaft position indexing across 3500 Machinery Protection System platforms. It converts proximity probe or magnetic pickup analog inputs into TTL-compatible digital timing pulses for downstream speed and vibration processing within rack-based monitoring architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/25-01-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eProvided by 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Channel Keyphasor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1 input channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eProximity probe or magnetic pickup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e±50 V input capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Output\u003c\/td\u003e\n\u003ctd\u003eTTL-compatible digital pulses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Range\u003c\/td\u003e\n\u003ctd\u003e1 to 120000 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003e3500 rack \/ System 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy Current Phase Conditioning and Signal Edge Formation\u003c\/h3\u003e\n\u003cp\u003eThe module processes eddy-current probe waveform distortion into stable phase-edge detection for once-per-revolution indexing.\u003cbr\u003eSignal conditioning maintains phase integrity under variable air-gap voltage conditions.\u003cbr\u003eThe system supports cross-reference alignment for orbit and vector calculation in multi-module 3500 configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support both proximity probes and magnetic pickups on the same channel?\u003cbr\u003eA: The input channel is configurable for either probe type, but not simultaneous dual-sensor operation.\u003c\/p\u003e\n\u003cp\u003eQ: What happens to phase output during rack module replacement?\u003cbr\u003eA: Phase output is interrupted during removal unless redundant Keyphasor modules are installed.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module generate multiple pulses per revolution?\u003cbr\u003eA: Yes, pulse generation can be configured for once-per-turn or multi-pulse encoding depending on system setup.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in an approved 3500 rack slot with correct backplane alignment.\u003cbr\u003eRoute probe wiring separately from power conductors to reduce electromagnetic coupling.\u003cbr\u003eMaintain shield continuity to system ground at a single termination point.\u003cbr\u003eVerify probe gap voltage and polarity prior to enabling phase acquisition.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44306888523864,"sku":"3500\/25-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350025_e2b1f2bf-ab5b-4412-b93f-811fd1da5667.jpg?v=1782984631","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-3500-25-01-01-00-keyphasor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}