{"product_id":"bently-nevada-3500-15-114m5329-01-high-voltage-dc-power-supply-module","title":"Bently Nevada 3500\/15 114M5329-01 High Voltage DC Power Supply Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 3500\/15 114M5329-01 High Voltage DC Power Supply Module\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15 114M5329-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15 High Voltage DC Power Supply Module\u003c\/strong\u003e, operates as a regulated power conversion unit for DC bus distribution within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Machinery Monitoring Rack System\u003c\/strong\u003e. It converts 88 to 140 VDC input into stabilized rack-level supply rails and maintains continuous module power delivery under redundant or single-supply configurations.\u003c\/p\u003e\n\u003cp\u003eConfigured for DC power conditioning in 3500 rack architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15 114M5329-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3500\/15 High Voltage DC Power Supply Module\u003c\/strong\u003e) provides direct electrical execution through regulated conversion, load sharing, and controlled redundancy switching.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/15 114M5329-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 × 25.2 × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 194 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e88 to 140 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual supply operation supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swap Capability\u003c\/td\u003e\n\u003ctd\u003eSupported with parallel supply present\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRedundant Power Bus Regulation and Hot-Swap Control\u003c\/h3\u003e\n\u003cp\u003eThe module implements DC bus regulation across parallel supply configurations, maintaining controlled current sharing between primary and backup units. During redundancy operation, load transfer occurs without interruption of rack backplane voltage. Hot-swap insertion and removal are supported only when at least one active supply maintains stable output, preventing transient collapse of downstream monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 3500\/15 114M5329-01 be inserted or removed under load?\u003cbr\u003eA: Yes. Hot-swap is supported when at least one redundant supply maintains stable rack power.\u003c\/p\u003e\n\u003cp\u003eQ: How is redundancy handled between two power supplies?\u003cbr\u003eA: The supplies operate in parallel with load sharing and automatic backup takeover upon primary degradation.\u003c\/p\u003e\n\u003cp\u003eQ: What happens during undervoltage conditions at the input stage?\u003cbr\u003eA: The module continues regulated output until internal thresholds trigger protective shutdown of conversion stages.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module only in designated 3500 rack power slots. Verify correct polarity and voltage range before energizing the input stage. Ensure redundant units are matched and properly seated for load sharing operation. Maintain chassis grounding continuity to reduce circulating currents. Do not perform insertion or removal unless at least one active supply maintains rack voltage stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44306823872600,"sku":"3500\/15 114M5329-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350015-01-00-00.jpg?v=1782982472","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-3500-15-114m5329-01-high-voltage-dc-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}