{"product_id":"bently-nevada-3500-15-02-00-00-dc-power-supply-module","title":"Bently Nevada 3500\/15-02-00-00 DC Power Supply Module","description":"\u003ch1 class=\"\"\u003eBently Nevada 3500\/15-02-00-00 DC Power Supply Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15-02-00-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-02-00-00 DC Power Supply Module\u003c\/strong\u003e, operates as a dedicated hardware component for regulated DC power distribution within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Machinery Monitoring System\u003c\/strong\u003e. It converts AC input into +24 VDC output and supplies rack-level power to monitoring and interface modules under continuous load conditions.\u003c\/p\u003e\n\u003cp\u003eConfigured for rack power conditioning in the 3500 system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15-02-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3500\/15-02-00-00 DC Power Supply Module\u003c\/strong\u003e) provides direct electrical execution through regulated DC bus stabilization and protection control.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/15-02-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+24 VDC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 6 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eOvercurrent, overvoltage, short-circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eParallel operation supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003e19-inch rack \/ DIN rail compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDC Bus Power Regulation and Redundancy Behavior\u003c\/h3\u003e\n\u003cp\u003eThe module maintains regulated DC bus stability for 3500 rack loads under variable AC input conditions. Parallel configuration enables shared current loading across dual supply units. Redundancy logic allows continuous operation during single supply degradation, with output decoupling to prevent backfeed between parallel units.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 3500\/15-02-00-00 operate in hot-swap configuration?\u003cbr\u003eA: The module supports replacement in rack systems, but load sharing must be stable before insertion or removal to avoid DC bus disturbance.\u003c\/p\u003e\n\u003cp\u003eQ: How is redundancy implemented in parallel operation?\u003cbr\u003eA: Redundancy is achieved through parallel output operation with current sharing behavior and isolation between supply outputs.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if output voltage exceeds protection thresholds?\u003cbr\u003eA: Overvoltage protection triggers internal shutdown to isolate the DC output from downstream modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a compliant 3500 rack power slot with correct AC feed verification. Ensure grounding continuity between rack chassis and system earth. Maintain separation between AC input wiring and low-level signal cabling to reduce conducted noise. For redundant configurations, verify phase alignment and load sharing balance before energizing both supplies. Do not insert or remove the module under unstable load conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44306822266968,"sku":"3500\/15-02-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350015127610-01125840-01_20f76cc5-2682-4479-b541-c6aa9630592f.jpg?v=1782982100","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-3500-15-02-00-00-dc-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}