{"product_id":"bently-nevada-330905-07-17-05-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330905-07-17-05-02-05 3300 NSv Proximity Probe","description":"\u003ch2\u003eBently Nevada 330905-07-17-05-02-05 3300 NSv Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330905-07-17-05-02-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330905\u003c\/strong\u003e 3300 NSv Proximity Probe, operates as a dedicated hardware component for eddy-current shaft displacement measurement within the 3300 XL NSv Transducer System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330905-07-17-05-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 thread; 70 mm unthreaded length; 170 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-34 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive probe element; powered through compatible Proximity System interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Type\u003c\/td\u003e\n\u003ctd\u003eWithout armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial FEP insulated standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel calibration target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals including CSA, ATEX, IECEx options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Measurement and Rotor Dynamics Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330905-07-17-05-02-05 uses eddy-current probe scaling to convert shaft displacement into proportional electrical output signals. The probe works with compatible 3300 XL NSv Proximitor modules to provide radial vibration and position measurement data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the system requires gap voltage validation during commissioning. Technicians normally verify probe operation against the -10 VDC target gap voltage condition to confirm correct probe-to-shaft spacing.\u003c\/p\u003e\n\u003cp\u003eThe narrow side-view construction supports rotor dynamics monitoring applications where installation clearance limits standard probe mounting. Furthermore, the probe design reduces installation interference when measuring small shafts below 51 mm or flat targets below 15 mm.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What measurement principle does the 330905-07-17-05-02-05 use?\u003cbr\u003eA: The probe uses eddy-current technology to measure relative shaft displacement through electromagnetic field variation between the probe tip and conductive target surface.\u003c\/p\u003e\n\u003cp\u003eQ: Does this probe include an armored cable design?\u003cbr\u003eA: No. The 330905-07-17-05-02-05 configuration uses a standard cable without armor protection.\u003c\/p\u003e\n\u003cp\u003eQ: What connector type does this proximity probe use?\u003cbr\u003eA: The probe uses a miniature coaxial ClickLoc connector designed for secure connection with compatible 3300 XL NSv system components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the probe with the correct M10 x 1 threaded mounting arrangement and maintain proper mechanical alignment between the probe tip and the measured shaft surface.\u003c\/p\u003e\n\u003cp\u003eRoute the coaxial cable separately from high-current power conductors and variable frequency drive output cables to reduce electrical interference. Maintain proper cable bending practices to prevent damage to the FEP insulation and connector assembly.\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, verify probe polarity, signal output, and gap voltage before placing the monitoring channel into service. Confirm that the probe tip faces the target surface without mechanical contact during machine operation.\u003c\/p\u003e\n\u003cp\u003eConnect the ClickLoc connector securely and verify that the cable shield follows the system grounding requirements specified for the 3300 XL NSv installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44407768711256,"sku":"330905-07-17-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330905-07-17-05-02-05-3.jpg?v=1784622369","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-330905-07-17-05-02-05-3300-nsv-proximity-probe","provider":"IndustriaX Limited","version":"1.0","type":"link"}