{"product_id":"bently-nevada-330425-01-05-accelerometer-transducer","title":"Bently Nevada 330425-01-05 Accelerometer Transducer","description":"\u003ch2\u003eBently Nevada 330425-01-05 Accelerometer Transducer\u003c\/h2\u003e\n\u003cp\u003eConfigured for casing vibration acceleration measurement in TSI machinery monitoring systems, the \u003cstrong\u003eBently Nevada 330425-01-05\u003c\/strong\u003e (\u003cstrong\u003e330425 accelerometer transducer\u003c\/strong\u003e) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 330425-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.5 x 2.5 x 2.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e-67 to 250 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e2.5 mV\/m\/s2 (25 mV\/g) +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 15 kHz \/ 30 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e+\/-1% up to 735 m\/s2 (75 g peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF integral stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCross-Talk Suppression and Rotordynamic Signal Conditioning (Bently Nevada specific)\u003c\/h3\u003e\n\u003cp\u003eThe 330425-01-05 sensor architecture follows Bently Nevada machinery monitoring principles with emphasis on rotordynamic signal integrity. Mechanical-to-electrical conversion is optimized for casing acceleration capture under high-frequency excitation conditions. The sensing element design supports cross-talk suppression between axial and transverse vibration components, maintaining axial sensitivity deviation below 5%.\u003c\/p\u003e\n\u003cp\u003eSignal scaling behavior is aligned with eddy-current probe reference frameworks used in condition monitoring chains, enabling consistent amplitude correlation between acceleration and derived vibration velocity models. System-level integration supports gap voltage validation logic with reference operating envelopes approaching -10 VDC baseline conditions in associated transducer networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 330425-01-05 be directly integrated into existing Bently Nevada monitoring channels?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It is electrically compatible with standard accelerometer input modules supporting 24 VDC excitation and mV-level charge input conditioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the impact of mounting torque on measurement stability?\u003c\/strong\u003e\u003cbr\u003eA: Improper stud engagement at the 1\/4-28 UNF interface can introduce mechanical preload variation, affecting high-frequency response above 10 kHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the sensor support hot-swap operation in energized systems?\u003c\/strong\u003e\u003cbr\u003eA: No hot-swap is supported. Signal line disconnection under excitation may cause transient overvoltage at the conditioning input stage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting surface is rigid, flat, and free of paint or insulating layers to maintain consistent mechanical coupling. The 1\/4-28 UNF stud must achieve full thread engagement to prevent resonance detuning under high-g vibration.\u003c\/p\u003e\n\u003cp\u003eSignal cable routing must maintain separation from high-voltage conductors to reduce induced noise. Shield termination should be grounded at a single point on the monitoring system side to avoid ground loop formation.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive bending stress near the sensor base; minimum bend radius should comply with standard industrial instrumentation cable practices. Environmental sealing should be verified for applications approaching upper temperature limits of 250 degF.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44290652209240,"sku":"330425-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330425-01-05-3.jpg?v=1782720850","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-330425-01-05-accelerometer-transducer","provider":"IndustriaX Limited","version":"1.0","type":"link"}