{"product_id":"bently-nevada-3300-16-12-01-01-00-00-dual-vibration-monitor-module","title":"Bently Nevada 3300\/16-12-01-01-00-00 Dual Vibration Monitor Module","description":"\u003ch1\u003eBently Nevada 3300\/16-12-01-01-00-00 Dual Vibration Monitor Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for radial vibration and gap signal conditioning in 3300 Machinery Monitoring System,the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16-12-01-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3300\/16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual Vibration Monitor Module) provides direct physical\/electrical execution. The module processes dual proximity probe inputs for vibration amplitude and average shaft position (gap), converting eddy-current transducer signals into conditioned analog outputs and relay trip logic.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003ctd\u003eBase Module\u003c\/td\u003e\n\u003ctd\u003eXY \/ Gap Dual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-12\u003c\/td\u003e\n\u003ctd\u003eFull Scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 um pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e3300 \/ 7200 \/ 3300XL Proximitor compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eEpoxy sealed SPDT relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eSafety Barriers\u003c\/td\u003e\n\u003ctd\u003eNot installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003eNot enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300\/16-12-01-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e2 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 or 2 proximity probe inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4 Hz to 4000 Hz (standard), 1 Hz to 600 Hz (low speed option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA, 0 to -10 VDC, 1 to 5 VDC selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd\u003eSPDT epoxy sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Output\u003c\/td\u003e\n\u003ctd\u003eFront panel coaxial per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with eddy-current proximity transducers using calibrated scaling typically based on 200 mV\/mil sensitivity (approx 7.87 V\/mm). Input conditioning circuitry performs continuous gap voltage validation against expected shaft position windows, ensuring stable DC offset tracking across thermal drift conditions.\u003c\/p\u003e\n\u003cp\u003eCross-talk suppression is implemented at the channel separation stage, where dual-channel processing isolates orthogonal vibration vectors (X and Y axes). This prevents phase coupling errors in rotor dynamic interpretation, particularly in closely mounted probe geometries.\u003c\/p\u003e\n\u003cp\u003eRotor dynamic response is derived from band-limited vibration extraction, with selectable frequency windows optimized for low-speed shaft behavior below 1000 RPM and high-speed turbomachinery profiles up to 4000 Hz.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the module operate with a single proximity probe input only?\u003cbr\u003eA: Yes. The second channel can remain unused, but channel diagnostics will flag inactive input unless bypassed via configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does hot-swapping the module affect backplane signal integrity?\u003cbr\u003eA: The 3300 rack architecture does not support live hot-swap without transient interruption on shared backplane lines.\u003c\/p\u003e\n\u003cp\u003eQ: What determines relay trip activation timing?\u003cbr\u003eA: Relay actuation is governed by internal comparison logic between filtered vibration signal and configured alert\/danger thresholds with fixed processing latency.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module only in a compatible 3300 rack slot with verified backplane alignment. Maintain shield continuity for all proximity probe cabling and ensure single-point grounding at the system chassis.\u003c\/p\u003e\n\u003cp\u003eAvoid routing low-level probe signals alongside high-energy switching conductors to minimize induced noise. Torque all terminal connections to manufacturer-recommended mechanical retention limits.\u003c\/p\u003e\n\u003cp\u003eVerify channel scaling calibration prior to commissioning using known gap reference voltages. Ensure airflow clearance within enclosure remains unobstructed for thermal stability under continuous 2 W dissipation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44244823441496,"sku":"3300\/16-12-01-01-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330016-12-01-01-00-00-3.jpg?v=1781575263","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-3300-16-12-01-01-00-00-dual-vibration-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}