{"product_id":"bently-nevada-3300-16-12-01-01-00-00-00-vibration-monitor-module","title":"Bently Nevada 3300\/16-12-01-01-00-00-00 Vibration Monitor Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 3300\/16-12-01-01-00-00-00 Vibration Monitor Module\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16-12-01-01-00-00-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVibration Monitor Module, operates as a dedicated hardware component for multi-channel vibration and position signal processing within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eBently Nevada\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e3300 rack monitoring platform\u003c\/strong\u003e. The module processes proximity probe and seismic transducer inputs through rack-bus acquisition, producing alarm logic outputs and condition data streams.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-12-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.0 in x 0.0 in x 9.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 3300 rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e12 dynamic channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eEddy current proximity probes, seismic transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, relay alarm contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003e3300 rack bus, optional Modbus gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Cross-Channel Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe module processes eddy-current probe signals through internal scaling networks aligned to displacement-to-voltage transfer functions. Input channels apply gain normalization to maintain consistent gap voltage representation across probe sets, including axial position measurement chains.\u003c\/p\u003e\n\u003cp\u003eCross-channel signal processing is synchronized at rack level, reducing phase drift between vibration and position channels during steady-state and transient acquisition. The architecture applies channel grouping logic to prevent inter-channel interference in multi-probe configurations, particularly in tightly coupled rotor bearing systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does each channel support independent alarm threshold configuration?\u003cbr\u003eA: Yes. Each of the 12 channels supports independent alert and danger threshold parameters with relay output assignment.\u003c\/p\u003e\n\u003cp\u003eQ: Is the module hot-swappable within the 3300 rack?\u003cbr\u003eA: No. The 3300 legacy architecture does not guarantee hot-swap continuity; rack power interruption is typically required for module replacement.\u003c\/p\u003e\n\u003cp\u003eQ: Can 4-20 mA outputs be mapped per channel?\u003cbr\u003eA: Yes. Each dynamic channel can be configured to produce proportional 4-20 mA outputs based on measured vibration or position values.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall module into designated 3300 rack slot with backplane alignment confirmed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure rack power is isolated before insertion or removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between probe signal wiring and relay output cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded twisted-pair conductors for proximity probe inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround cable shields at single-point earth reference only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify correct probe-to-channel mapping prior to commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid routing sensor wiring parallel to high-voltage switching conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44319564726360,"sku":"3300\/16-12-01-01-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330016-12-01-03-00-00-002.jpg?v=1783067486","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-3300-16-12-01-01-00-00-00-vibration-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}