{"product_id":"bently-nevada-24583-03-3300-xl-proximitor-sensor","title":"Bently Nevada 24583-03 3300 XL Proximitor Sensor","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 24583-03 3300 XL Proximitor Sensor\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 24583-03\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edisplacement monitoring module, operates as a dedicated hardware component for conversion of eddy-current probe signals into calibrated vibration and shaft position data within 3300 XL monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e24583-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e76 x 25 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e2 mm to 80 mm (probe dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e0.25 mm to 2.0 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25 percent of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL proximity probe compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e-200 mV\/mil (7.87 mV\/um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e-24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eAPI 670, CE, UL, CSA, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBently Nevada Eddy-Current Transduction and Rotor Dynamics Interface\u003c\/h3\u003e\n\u003cp\u003eThe 24583-03 processes eddy-current probe impedance variation into linear displacement voltage conversion using calibrated scaling coefficients defined for the 3300 XL probe family. Probe gap voltage reference behavior is tied to baseline air-gap conditions for shaft centerline tracking, with sensitivity mapping maintained across the defined linear operating window. Rotor dynamics evaluation is derived from DC-coupled displacement signals supporting low-frequency orbit analysis and synchronous vibration extraction. Cross-channel electrical interference is mitigated through internal shielding and grounded reference topology within the sensor interface stage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 24583-03 compatible with non-3300 XL proximity probes?\u003cbr\u003eA: No. The input conditioning network is calibrated for 3300 XL probe electrical characteristics. Non-matching probe impedance may result in non-linear output scaling.\u003c\/p\u003e\n\u003cp\u003eQ: Does the sensor output require external signal conditioning before monitoring systems?\u003cbr\u003eA: No additional conditioning is required. The device provides direct proportional voltage output (-200 mV\/mil) suitable for monitoring system input channels.\u003c\/p\u003e\n\u003cp\u003eQ: How is signal stability affected during power supply fluctuation on -24 VDC input?\u003cbr\u003eA: Internal regulation maintains signal scaling integrity within nominal -24 VDC operation. Deviations outside tolerance may affect output linearity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a grounded metallic enclosure to maintain signal shielding integrity for eddy-current measurement circuits. Maintain separation between probe signal wiring and high-voltage or switching conductors to reduce electromagnetic coupling. Use twisted, shielded cable for probe connections, with single-point shield termination at the monitoring system end. Ensure probe extension cables are routed without sharp bends to avoid impedance discontinuities. Verify correct polarity of the -24 VDC supply prior to system energization.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44291604414552,"sku":"24583-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/24583-03.jpg?v=1782729845","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-24583-03-3300-xl-proximitor-sensor","provider":"IndustriaX Limited","version":"1.0","type":"link"}