{"product_id":"bently-nevada-16925-20-interconnect-cable-1","title":"Bently Nevada 16925-20 Interconnect Cable","description":"\u003ch2\u003eBently Nevada 16925-20 Interconnect Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for signal transmission between vibration sensing elements and machinery protection input modules in Bently Nevada 3500 Series monitoring architecture, the \u003cstrong\u003eBently Nevada 16925-20\u003c\/strong\u003e (\u003cstrong\u003e16925\u003c\/strong\u003e interconnect cable) provides direct electrical interconnection between accelerometer\/Velomitor sensor outputs and acquisition electronics.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 16925-20\u003c\/strong\u003e functions as a 3-conductor shielded signal path designed for low-level dynamic vibration signal transport with controlled impedance and EMI suppression characteristics.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model: 16925 interconnect cable series\u003c\/li\u003e\n\u003cli\u003eSuffix \"-20\": factory-defined cable length equal to 20 ft (approx. 6.1 m)\u003c\/li\u003e\n\u003cli\u003eNo additional electrical variant encoding present in suffix structure\u003c\/li\u003e\n\u003cli\u003eElectrical behavior remains consistent across length variants within 16925 family\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 16925-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg to 2.0 kg (packaging dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (no power consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Count\u003c\/td\u003e\n\u003ctd\u003e3 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003e22 AWG tinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003e100 percent tinned copper braid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 300 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 60 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohm +\/- 3 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Signal Integrity Suppression Mechanism (Bently Nevada System Binding)\u003c\/h3\u003e\n\u003cp\u003eWithin the vibration monitoring chain, \u003cstrong\u003eBently Nevada\u003c\/strong\u003e interconnect assemblies such as the 16925-20 are engineered to maintain controlled impedance continuity between sensor transducers and monitor input conditioning stages.\u003c\/p\u003e\n\u003cp\u003eIn rotating machinery measurement loops, shielding geometry and braid coverage are used to reduce cross-talk coupling between adjacent channels, particularly in multi-probe configurations where eddy-current proximity probe channels and velocity transducers operate in close routing proximity. The cable design supports stable low-amplitude signal transport without introducing measurable phase distortion under standard 3500 Series acquisition bandwidths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 16925-20 support hot-swap during live vibration monitoring?\u003c\/strong\u003e\u003cbr\u003eA: No. The cable is a passive interconnect. Connection or disconnection under energized sensor loop conditions may introduce transient signal spikes at the monitor input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the shielding terminated at both ends?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The overall braid shield is intended to be terminated to system ground reference at connector interfaces to maintain EMI rejection integrity across the full signal path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does cable length variation affect impedance matching?\u003c\/strong\u003e\u003cbr\u003eA: Within the 16925 series, impedance is controlled to 50 ohm nominal. Length variations primarily affect total capacitance load, not characteristic impedance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain continuous shield termination at connector backshell interfaces\u003c\/li\u003e\n\u003cli\u003eAvoid parallel routing with high voltage or switching power conductors\u003c\/li\u003e\n\u003cli\u003eMinimum bend radius should follow standard industrial cable handling practice for 22 AWG shielded instrumentation cable\u003c\/li\u003e\n\u003cli\u003eInstall within conduit when exposed to mechanical abrasion zones or high traffic routing areas\u003c\/li\u003e\n\u003cli\u003eEnsure proper strain relief at both sensor and monitor termination points to prevent conductor fatigue\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44254823022680,"sku":"16925-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/16925-20-2.jpg?v=1781768098","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-16925-20-interconnect-cable-1","provider":"IndustriaX Limited","version":"1.0","type":"link"}