{"product_id":"bently-nevada-149787-01-tim-input-card","title":"Bently Nevada 149787-01 TIM Input Card","description":"\u003ch2\u003eBently Nevada 149787-01 TIM Input Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 149787-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e149787-01\u003c\/strong\u003e TIM Input Card, operates as a dedicated hardware component for simultaneous vibration signal acquisition within the Trendmaster Dynamic Scanning Module (DSM) system. It processes TIM sensor inputs through two independent input lines with synchronized sampling capability.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e149787-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTIM Input Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eTrendmaster Dynamic Scanning Module (DSM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Lines\u003c\/td\u003e\n\u003ctd\u003e2 input lines per card, both lines sampled simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported TIM Modules\u003c\/td\u003e\n\u003ctd\u003eAll proTIM modules, 1900\/15, 1900\/25, 1900\/55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIM Cable Length\u003c\/td\u003e\n\u003ctd\u003e1200 m (4000 ft) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-2% of full-scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current Limit\u003c\/td\u003e\n\u003ctd\u003e43 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Frequency Response\u003c\/td\u003e\n\u003ctd\u003e1\/3 Hz and 20 kHz 3 dB corners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Filter\u003c\/td\u003e\n\u003ctd\u003e2-pole high-pass, 1 Hz to 12.8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrime Spike Filter\u003c\/td\u003e\n\u003ctd\u003e4-pole high-pass, 1 Hz to 12.8 kHz; 2-pole low-pass, 10 Hz to 12.8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotor Region Filter\u003c\/td\u003e\n\u003ctd\u003e2-pole high-pass, 1 Hz to 12.8 kHz; 2-pole low-pass, 10 Hz to 12.8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Frequency Filter\u003c\/td\u003e\n\u003ctd\u003e4-pole high-pass, 1 Hz to 12.8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous Waveform Samples\u003c\/td\u003e\n\u003ctd\u003e32, 64, or 128 samples per revolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous Frequency Span\u003c\/td\u003e\n\u003ctd\u003e20 to 36,000 CPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Waveform Size\u003c\/td\u003e\n\u003ctd\u003e8192 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsynchronous Frequency Spans\u003c\/td\u003e\n\u003ctd\u003e20 Hz, 50 Hz, 100 Hz, 200 Hz, 500 Hz, 1000 Hz, 2000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsynchronous Sample Rates\u003c\/td\u003e\n\u003ctd\u003e51.2 Hz, 128 Hz, 256 Hz, 512 Hz, 1280 Hz, 2560 Hz, 5120 Hz, 12800 Hz, 25600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Lines\u003c\/td\u003e\n\u003ctd\u003e100, 200, 400, 800, 1600, 3200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectrum Averages\u003c\/td\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Scaling and Rotor Dynamics Processing\u003c\/h3\u003e\n\u003cp\u003eThe 149787-01 TIM Input Card acquires dynamic machinery signals through TIM interface modules and transfers conditioned measurement data into the DSM architecture. Moreover, the module supports vibration monitoring applications that require accurate signal conversion and frequency-domain analysis.\u003c\/p\u003e\n\u003cp\u003eThe input architecture maintains synchronized sampling across two TIM lines. Therefore, the card can process multiple sensor channels through connected proTIM modules while preserving timing relationships required for rotor dynamics evaluation.\u003c\/p\u003e\n\u003cp\u003eThe card supports configurable filtering paths, including direct filtering, prime spike filtering, rotor region filtering, and high frequency filtering. These functions allow the monitoring system to separate vibration components according to measurement frequency requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many TIM input lines does the 149787-01 TIM Input Card support?\u003cbr\u003eA: The card supports two TIM input lines, and both lines are sampled simultaneously.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 149787-01 support synchronous waveform acquisition?\u003cbr\u003eA: Yes. The module supports software-configurable synchronous waveforms with 32, 64, or 128 samples per revolution and waveform sizes up to 8192 samples.\u003c\/p\u003e\n\u003cp\u003eQ: Which TIM modules can connect to the 149787-01?\u003cbr\u003eA: The card supports all proTIM modules, including 1900\/15, 1900\/25, and 1900\/55 TIM modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 149787-01 TIM Input Card only in the designated DSM rack slot configuration defined by the Trendmaster system hardware manual.\u003c\/p\u003e\n\u003cp\u003eConnect TIM cables according to the approved wiring layout and maintain proper cable routing separation from high-voltage power conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable shielding and grounding practices at the system connection points. Avoid unnecessary cable loops and mechanical stress on TIM connectors during installation.\u003c\/p\u003e\n\u003cp\u003eVerify TIM module compatibility before commissioning. Check input signal behavior, communication status, and waveform acquisition settings through the connected monitoring software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44387412639832,"sku":"149787-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/149787-01-3.jpg?v=1784182414","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-149787-01-tim-input-card","provider":"IndustriaX Limited","version":"1.0","type":"link"}