{"product_id":"bently-nevada-136751-01-3500-dual-velocity-monitor-module","title":"Bently Nevada 136751-01 3500 Dual Velocity Monitor Module","description":"\u003ch2\u003eBently Nevada 136751-01 3500 Dual Velocity Monitor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136751-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e136751-01\u003c\/strong\u003e Dual Velocity Monitor Module, operates as a dedicated hardware component for velocity signal acquisition and vibration monitoring within the Bently Nevada 3500 Machinery Protection System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%; height: 411.648px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 25.1222%; height: 19.6023px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 71.8821%; height: 19.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003e136751-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003eDual Velocity Monitor Module \/ I\/O Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 39.2045px;\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 39.2045px;\"\u003eBently Nevada 3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 39.2045px;\"\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 39.2045px;\"\u003eDual-channel velocity monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eInput Signal\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003eVelocity transducer input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eSignal Processing\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003eVelocity signal conditioning and filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003e3500 rack-mounted module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003eApprox. 0.20 kg to 0.45 kg (assembly dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003e3500 Series rack module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 19.6023px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 19.6023px;\"\u003eUp to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 39.2045px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 39.2045px;\"\u003eLow-power operation within 3500 rack power budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 25.1222%; height: 39.2045px;\"\u003ePrimary Function\u003c\/td\u003e\n\u003ctd style=\"width: 71.8821%; height: 39.2045px;\"\u003eDual-channel machinery velocity monitoring and protection signal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Scaling and Rotor Dynamics Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 136751-01 module operates within the Bently Nevada machinery monitoring architecture where accurate vibration measurement depends on validated sensor scaling, signal conditioning, and dynamic response processing. The module interface is designed for integration with vibration monitoring loops requiring stable velocity measurement and diagnostic data acquisition.\u003c\/p\u003e\n\u003cp\u003eFor Bently Nevada 3500 system applications, sensor signal integrity depends on correct transducer configuration, cable shielding, and input calibration. Machinery protection engineering practices include verification of probe scaling factors, signal polarity, and measurement channel behavior before placing the monitoring loop into service.\u003c\/p\u003e\n\u003cp\u003eRotor dynamics evaluation requires consistent vibration signal processing to identify mechanical conditions such as imbalance, misalignment, and bearing-related vibration changes. The module supports continuous channel monitoring within the configured 3500 rack architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 136751-01 be installed in any Bently Nevada 3500 rack slot?\u003cbr\u003eA: Installation must follow the 3500 rack configuration rules and approved module placement defined by the system engineering documentation. Slot assignment depends on rack design and system configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 136751-01 provide independent measurement channels?\u003cbr\u003eA: Yes. The module is configured as a dual-channel velocity monitoring device, allowing two separate vibration measurement inputs to be processed within the monitoring system.\u003c\/p\u003e\n\u003cp\u003eQ: Are field wiring and grounding requirements important for this module?\u003cbr\u003eA: Yes. Shield termination, cable routing separation, and proper grounding practices are required to minimize electrical noise interference and maintain measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the module part number and rack configuration before installation or replacement.\u003c\/li\u003e\n\u003cli\u003eInstall the module only in a compatible Bently Nevada 3500 system rack.\u003c\/li\u003e\n\u003cli\u003eConfirm field wiring matches the approved terminal assignment and engineering drawings.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between vibration signal cables and high-current power wiring.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to plant grounding standards to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003ePerform channel verification and system configuration checks after module installation.\u003c\/li\u003e\n\u003cli\u003eFollow approved maintenance procedures before removing or inserting modules in an operating rack.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44341356036184,"sku":"136751-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/136751-01-2.jpg?v=1783419201","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-136751-01-3500-dual-velocity-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}