{"product_id":"bently-nevada-108000-02-adre-108-data-acquisition-instrument","title":"Bently Nevada 108000-02 ADRE 108 Data Acquisition Instrument","description":"\u003ch1 class=\"\"\u003eBently Nevada 108000-02 ADRE 108 Data Acquisition Instrument\u003c\/h1\u003e\n\u003cp\u003eConfigured for vibration diagnostics, predictive maintenance, and real-time monitoring of rotating machinery in ADRE platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 108000-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eADRE 108\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eData Acquisition Instrument) provides direct physical\/electrical execution of multi-channel signal acquisition and digitization across sensor inputs including vibration, displacement, temperature, and process signals.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo functional suffix segmentation or parameterized option structure is defined for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e108000-02\u003c\/strong\u003e. The designation represents a fixed configuration within the ADRE 108 instrument family.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e108000-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 in (H) x 17 in (W) x 10 in (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~20 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 simultaneous input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10 kHz per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eProximity probes, accelerometers, RTDs, thermocouples, process signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232 \/ RS-422 \/ Ethernet \/ OPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eInternal memory with external expansion support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics Acquisition \u0026amp; Cross-Talk Suppression Architecture\u003c\/h3\u003e\n\u003cp\u003eThe ADRE 108 platform integrates multi-channel synchronous sampling architecture for rotor dynamics analysis, supporting phase-coherent acquisition of vibration vectors across rotating machinery shafts. Eddy-current probe scaling is handled through conditioned input paths that preserve gap voltage linearity across measurement ranges. Cross-talk suppression is implemented at the channel isolation stage to minimize spectral contamination between adjacent input lines, maintaining signal separation integrity during multi-probe operation. The system supports alignment and trending workflows used in predictive diagnostics where phase stability and amplitude consistency are required across multiple acquisition cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 108000-02 support hot-swapping of input modules during acquisition?\u003cbr\u003eA: The unit does not support live removal of internal acquisition circuitry during active sampling. Power cycling is required for hardware-level configuration changes.\u003c\/p\u003e\n\u003cp\u003eQ: What is the limitation of sampling synchronization across channels?\u003cbr\u003eA: All 8 channels operate with synchronized sampling clocks, ensuring phase-aligned acquisition up to the maximum specified sampling rate of 10 kHz per channel.\u003c\/p\u003e\n\u003cp\u003eQ: How is sensor noise isolation maintained across mixed input types?\u003cbr\u003eA: Isolation is achieved through internal channel separation and controlled input conditioning stages to reduce interference between vibration and process signal paths.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall unit in a stable rack or enclosure with controlled ventilation to maintain thermal limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure all sensor cables use shielded twisted-pair conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields at a single-point ground reference to avoid ground loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between low-level signal wiring and high-voltage power lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify correct communication interface configuration (RS-232 \/ Ethernet) prior to commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform channel verification and signal integrity check before enabling continuous acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44301848477784,"sku":"108000-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/108000-02.jpg?v=1782898567","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-108000-02-adre-108-data-acquisition-instrument","provider":"IndustriaX Limited","version":"1.0","type":"link"}