{"product_id":"bently-nevada-1034549-10-fieldmonitor-24-vdc-power-supply-module","title":"Bently Nevada 1034549-10 FieldMonitor 24 VDC Power Supply Module","description":"\u003ch2\u003eBently Nevada 1034549-10 FieldMonitor 24 VDC Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 1034549-10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1701\/10\u003c\/strong\u003e FieldMonitor 24 VDC Power Supply Module, operates as a dedicated hardware component for DC power conversion and distribution within the Bently Nevada FieldMonitor terminal base system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1034549-10 \/ 1701\/10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFieldMonitor 24 VDC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada FieldMonitor 1701\/05 and 1701\/06 Terminal Bases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e+18 VDC to +36 VDC, 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A peak nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eUp to 50 VDC without damage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e850 VDC primary to chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Protection\u003c\/td\u003e\n\u003ctd\u003e250 V, 3 A slow-blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e105 mm x 150 mm x 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.57 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDC supply conversion for FieldMonitor internal logic and connected monitoring modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBently Nevada FieldMonitor Power Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1034549-10 module performs DC power conditioning for FieldMonitor monitoring assemblies installed in 1701 series terminal bases. Moreover, it maintains regulated internal supply levels for adjacent monitoring modules while providing electrical isolation between the input source and chassis reference.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial DC input variations from +18 VDC to +36 VDC. Therefore, it can maintain stable operation during normal fluctuations in plant DC distribution systems. The internal fuse protection limits fault current conditions and protects the power conversion circuitry from external electrical events.\u003c\/p\u003e\n\u003cp\u003eFor machinery monitoring installations, the module operates alongside FieldMonitor signal processing hardware that manages vibration and machine condition inputs. In addition, the power design supports electrical noise reduction required for proximity probe and vibration monitoring environments.\u003c\/p\u003e\n\u003cp\u003eBently Nevada monitoring architectures often require controlled signal behavior, including eddy-current probe scaling, gap voltage validation, rotor dynamics evaluation, and cross-talk suppression. The 1034549-10 provides the regulated DC power foundation required for these monitoring functions by maintaining stable electrical conditions at the terminal base level.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1034549-10 Power Supply Module accept a 24 VDC industrial power source directly?\u003cbr\u003eA: Yes. The module accepts +18 VDC to +36 VDC input power with 24 VDC as the nominal operating voltage.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide electrical isolation between input power and chassis ground?\u003cbr\u003eA: Yes. The module provides 850 VDC isolation between the primary input circuit and chassis reference.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 1034549-10 designed for installation in 1701 series FieldMonitor terminal bases?\u003cbr\u003eA: Yes. The module installs into the dedicated power slot of Bently Nevada 1701\/05 and 1701\/06 FieldMonitor terminal bases.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the 1034549-10 module only in the designated power supply position of the compatible FieldMonitor terminal base.\u003c\/li\u003e\n\u003cli\u003eVerify DC polarity before connecting external power wiring to prevent input damage.\u003c\/li\u003e\n\u003cli\u003eRoute DC power cables separately from high-current motor cables and high-frequency switching conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect chassis grounding according to site electrical standards to maintain proper isolation performance.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections for mechanical tightness and ensure the module seats completely within the terminal base slot.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate enclosure ventilation to keep operating temperature within the specified range.\u003c\/li\u003e\n\u003cli\u003eUse shielded signal wiring practices for adjacent vibration monitoring channels where required by the installation design.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44372077772888,"sku":"1034549-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/1034549-10-3.jpg?v=1783938223","url":"https:\/\/www.industriaxplc.com\/id\/products\/bently-nevada-1034549-10-fieldmonitor-24-vdc-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}