{"product_id":"armored-interconnect-cable-bently-nevada-16710-20-16710-08","title":"Armored Interconnect Cable Bently Nevada 16710-20 16710-08","description":"\u003ch1\u003eBently Nevada 16710-08 Armored Interconnect Cable\u003c\/h1\u003e\n\u003cp\u003eConfigured for vibration signal transmission in Bently Nevada 3500 and 3300 series machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16710-08\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(base model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710\u003c\/strong\u003e) provides direct physical and electrical execution between accelerometers and monitoring racks. It carries conditioned dynamic signals from transducers to input modules without intermediate conversion.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eParameter\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBently Nevada\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e16710-08\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOrigin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnited States\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.824 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.4 m length\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating Temp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 degC to 85 degC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Consumption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePassive component; no power draw\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConductor Count\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWire Gauge\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e22 AWG (0.5 mm²)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShielding\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFoil and braid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInsulation Material\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePVC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e600 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCurrent Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 16710-08 supports eddy-current probe scaling by preserving linear signal amplitude over the full transducer operating range. When interfaced with proximity probes, it maintains stable gap voltage validation targets near -10 VDC, ensuring rotor dynamics measurements remain consistent under varying shaft displacement. Full shielding suppresses cross-talk between adjacent signal pairs in high-density machinery monitoring cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 16710-08 be hot-swapped while the monitoring system is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnect power from the associated monitoring module before connecting or disconnecting the cable to prevent transient surges.\u003c\/p\u003e\n\u003cp\u003eQ: Is the armor electrically bonded to the shield?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The stainless-steel armor is bonded to the overall shield to ensure continuous EMI protection and ground reference integrity.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum continuous current rating for signal conductors?\u003c\/p\u003e\n\u003cp\u003eA: Conductors are rated for up to 10 A, though typical vibration signal currents are well below this limit.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high-voltage power conductors to minimize inductive coupling. Maintain minimum bend radius of 10× cable diameter. Terminate the shield at the monitoring rack end using the designated grounding point; do not ground at the transducer end to avoid ground loops. Verify connector seating by applying slight axial force after locking the 3-socket plug. Inspect armor continuity during annual preventive maintenance.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44248146149464,"sku":"16710-08","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/16710-08-3.jpg?v=1781664364","url":"https:\/\/www.industriaxplc.com\/id\/products\/armored-interconnect-cable-bently-nevada-16710-20-16710-08","provider":"IndustriaX Limited","version":"1.0","type":"link"}