{"product_id":"anb10d-410-s2-yokogawa-node-interface-unit","title":"ANB10D-410\/S2 | Yokogawa Node Interface Unit","description":"\u003ch2\u003eYokogawa ANB10D-410\/S2 Node Interface Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-410\/S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D\u003c\/strong\u003e Node Unit, operates as a dedicated hardware component for interfacing analog and digital I\/O signals via a dual-redundant ESB bus within CENTUM VP \/ CENTUM CS 3000 Distributed Control Systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ANB10D-410\/S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg (excluding I\/O modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mountable, standard EIA 3U height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorageTemp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingHumidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunicationBus\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Slots\u003c\/td\u003e\n\u003ctd\u003eUp to 8 FIO modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerSupply\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC, dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eMax. 200 VA (depending on installed I\/O modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstandingVoltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC, 1 min between power and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulationResistance\u003c\/td\u003e\n\u003ctd\u003e≥ 20 MΩ at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA \/ HART Loop Support:\u003c\/strong\u003e Compatible with analog input and output signals for direct field device connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus Connectivity:\u003c\/strong\u003e Supports digital communication over the ESB bus for integrated I\/O control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation:\u003c\/strong\u003e Provides electrical isolation between I\/O channels to prevent cross-channel interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC):\u003c\/strong\u003e Maintains thermocouple measurement accuracy under variable ambient conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the Node Unit I\/O modules be replaced while the system is operating?\u003cbr\u003eA: Hot-swapping of I\/O modules is supported, provided the dual-redundant power supplies remain operational.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum number of I\/O modules per node?\u003cbr\u003eA: Up to 8 FIO modules can be installed in a single ANB10D-410\/S2 node unit.\u003c\/p\u003e\n\u003cp\u003eQ: How is the ESB bus redundancy handled in case of a single bus failure?\u003cbr\u003eA: The dual-redundant ESB bus automatically maintains communication through the operational bus without interruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit in a standard 19-inch EIA rack with adequate airflow for heat dissipation.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the chassis to reduce electrical noise and maintain isolation integrity.\u003c\/li\u003e\n\u003cli\u003eRoute ESB and power cables separately from high-voltage or high-frequency lines to prevent interference.\u003c\/li\u003e\n\u003cli\u003eVerify polarity and voltage levels of power supply connections before energizing.\u003c\/li\u003e\n\u003cli\u003eConfirm all I\/O modules are properly seated and locked before system startup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44186770112600,"sku":"ANB10D-410\/S2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANB10D-410S2-3.jpg?v=1780621421","url":"https:\/\/www.industriaxplc.com\/id\/products\/anb10d-410-s2-yokogawa-node-interface-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}