{"product_id":"allen-bradley-2711-k5a15l2-operator-interface","title":"Allen-Bradley 2711-K5A15L2 PanelView Standard Operator Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Allen-Bradley 2711-K5A15L2 is a robust industrial human-machine interface (HMI) terminal from the PanelView Standard series, engineered for reliable command and diagnostic monitoring in demanding industrial environments. This unit is specifically designed for applications requiring high-durability input methods, such as automotive assembly, material handling, and wastewater treatment facilities. Featuring a 5.5-inch monochrome LCD and a tactile mechanical keypad, the terminal provides operators with clear visibility of process loops, machine status, and alarm conditions, facilitating rapid response and reduced downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Interface:\u003c\/strong\u003e Tactile mechanical keypad with numeric matrix and F1-F10 function keys, ideal for high-vibration environments where touchscreens may be impractical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Communication:\u003c\/strong\u003e Integrated ControlNet port for high-speed, time-critical data exchange with host programmable logic controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Support:\u003c\/strong\u003e Dedicated RS-232 printer port for generating hardcopy fault summaries, sequence logs, and diagnostic reports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Design:\u003c\/strong\u003e Operates on 100-240 VAC with integrated line filtering to mitigate electromagnetic interference and grid fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Display:\u003c\/strong\u003e 5.5-inch blue monochrome LCD with 256 x 128 pixel resolution for clear, high-contrast process visualization.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis operator terminal is suited for legacy automation systems where deterministic communication and physical keypad input are required. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAutomotive assembly lines\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveyor control\u003c\/li\u003e\n\u003cli\u003eWastewater treatment process monitoring\u003c\/li\u003e\n\u003cli\u003eLocalized machine diagnostics and alarm management\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K5A15L2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eBlue Monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.5 inch (5.3 inch active area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e256 x 128 Pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003eRS-232 (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the unit is mounted in a NEMA-rated enclosure suitable for the application environment to maintain the integrity of the front panel seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Always connect the chassis ground terminal to a low-impedance earth ground to prevent electrical noise interference and ensure operator safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Verify that the input voltage matches the 100-240 VAC specification before applying power. Use shielded cables for communication lines to minimize EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e This device contains sensitive electronic components. Handle with care and ensure the power is disconnected before performing any wiring or maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Maintain adequate clearance around the unit to ensure proper airflow and prevent overheating during continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the 2711-K5A15L2 compatible with modern Ethernet networks?\u003c\/h3\u003e\u003cp\u003eNo, this specific model is designed for ControlNet communication. It does not support native Ethernet\/IP connectivity.\u003c\/p\u003e\u003ch3\u003eCan this unit replace a touchscreen model?\u003c\/h3\u003e\u003cp\u003eThis unit is designed for applications requiring a mechanical keypad. While it can replace other PanelView Standard units, ensure your application logic supports the specific ControlNet communication protocol used by this model.\u003c\/p\u003e\u003ch3\u003eWhat is the primary purpose of the RS-232 port?\u003c\/h3\u003e\u003cp\u003eThe RS-232 port on this model is configured as a dedicated printer port for outputting diagnostic logs and fault history, rather than for general-purpose PLC communication.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44673104674904,"sku":"2711-K5A15L2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_23da2029-effc-44d1-aabd-1334030d8461.jpg?v=1787935326","url":"https:\/\/www.industriaxplc.com\/id\/products\/allen-bradley-2711-k5a15l2-operator-interface","provider":"IndustriaX Limited","version":"1.0","type":"link"}