{"product_id":"allen-bradley-1769-im12-digital-ac-input-module","title":"Allen-Bradley 1769-IM12 Compact I\/O Digital AC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Allen-Bradley 1769-IM12 is a high-voltage digital AC input module engineered for use within CompactLogix and MicroLogix 1500 controller systems. This module provides 12 isolated input points designed to interface with 200–240 VAC field signals, making it a robust solution for monitoring industrial power distribution circuits, heavy machinery status, and high-voltage sensors. The module is designed to provide reliable signal conditioning and noise immunity in demanding electrical environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e12 high-voltage AC input points for 200–240 VAC applications.\u003c\/li\u003e\n\u003cli\u003eIntegrated signal filtering with a 20 ms delay to mitigate electrical noise.\u003c\/li\u003e\n\u003cli\u003eCompatible with CompactLogix and MicroLogix 1500 backplane systems.\u003c\/li\u003e\n\u003cli\u003eSupports DIN-rail or panel mounting for flexible cabinet integration.\u003c\/li\u003e\n\u003cli\u003eUses the 1769-RTBN18 removable terminal block for efficient field wiring and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically deployed in industrial automation systems requiring the monitoring of high-voltage AC signals. Common applications include monitoring motor starter status, power supply health, industrial lighting circuits, and high-voltage limit switches.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1769-IM12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e200\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e159–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Delay (On to Off)\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.65 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e40 VAC (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e159 VAC (Min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e22–14 AWG (Solid) \/ 22–16 AWG (Stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always disconnect system power before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlacement:\u003c\/strong\u003e For optimal performance, the module should be located within 8 slots of the system power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail or panel is properly grounded to provide a low-impedance path for electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use the 1769-RTBN18 terminal block. Ensure all field wiring is routed away from high-voltage AC power lines to prevent induced noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Use standard electrostatic discharge (ESD) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 1769-IM12?\u003c\/h3\u003e\u003cp\u003eThe 1769-IM12 is a digital input module that converts high-voltage AC signals (200–240 VAC) into logic-level signals that can be processed by a CompactLogix or MicroLogix 1500 controller.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all CompactLogix systems?\u003c\/h3\u003e\u003cp\u003eThe 1769-IM12 is designed for the Compact I\/O platform. It is compatible with CompactLogix systems that support 1769-series I\/O modules. Please verify your specific controller's backplane current capacity before adding modules.\u003c\/p\u003e\u003ch3\u003eDoes this module include the terminal block?\u003c\/h3\u003e\u003cp\u003eThe 1769-IM12 typically requires the 1769-RTBN18 removable terminal block for connection. Please check your specific order configuration to confirm if the terminal block is included.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44526200356952,"sku":"1769-IM12","price":93.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_cd347ee4-fa3a-40ba-9ccf-e24e3b2a910b.jpg?v=1786148152","url":"https:\/\/www.industriaxplc.com\/id\/products\/allen-bradley-1769-im12-digital-ac-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}