{"product_id":"abb-spiet800-infi-net-to-ethernet-transfer-module","title":"ABB SPIET800 INFI-Net to Ethernet Transfer Module","description":"\u003ch2\u003eABB SPIET800 INFI-Net to Ethernet Transfer Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for INFI-Net to Ethernet data transfer within ABB Symphony Plus and Harmony systems, the \u003cstrong\u003eABB SPIET800\u003c\/strong\u003e (\u003cstrong\u003eSPIET800\u003c\/strong\u003e INFI-Net to Ethernet Transfer Module) provides communication between the INFI-Net control network and Ethernet-based host systems. It supports data exchange with engineering, operator, OPC, and supervisory software environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSPIET800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eINFI-Net to Ethernet Transfer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eABB Ability Symphony Plus \/ Harmony\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eINFI-Net to Ethernet communication transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINFI-Net Interface\u003c\/td\u003e\n\u003ctd\u003eINFI-Net network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet communication, TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Software\u003c\/td\u003e\n\u003ctd\u003eS+ Engineering, S+ Operations (HSI), Harmony OPC Server, 800xA for Symphony Plus Harmony\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eVersion A_D or later recommended according to supplied information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Compatibility\u003c\/td\u003e\n\u003ctd\u003eFirmware updates should match the installed SPIET800 hardware and system release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eABB DCS rack\/chassis mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eStandard industrial process control environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Network Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe SPIET800 performs protocol-level communication between the INFI-Net control network and Ethernet-connected host systems. Therefore, the module should be treated as a network interface component rather than a conventional discrete I\/O module.\u003c\/p\u003e\n\u003cp\u003eEthernet communication uses TCP\/IP-based connectivity for host-side data exchange. In addition, the module supports integration with S+ Engineering, S+ Operations (HSI), Harmony OPC Server, and 800xA for Symphony Plus Harmony.\u003c\/p\u003e\n\u003cp\u003eFor ABB control-system installations, firmware compatibility must be checked against the installed system release before replacement or upgrade. The supplied information identifies version A_D or later as the recommended firmware level for addressing legacy vulnerability patches.\u003c\/p\u003e\n\u003cp\u003eThe module does not provide sufficient supplied data to establish a specific backplane communication rate, Ethernet port speed, channel count, or power-load value. These parameters should therefore be verified against the applicable ABB hardware manual before system engineering.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SPIET800 directly replace an existing module without checking firmware?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied data identifies firmware version A_D or later as recommended. The installed system release and module firmware compatibility should be verified before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the SPIET800 provide Ethernet communication?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The supplied specifications identify an Ethernet interface with TCP\/IP support for communication with host-side systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied information define the module power consumption?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. A specific power-consumption value is not provided. The applicable ABB hardware documentation should be used to determine the actual rack or backplane load.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the SPIET800 in the designated ABB DCS rack or chassis position.\u003c\/li\u003e\n\u003cli\u003eConfirm that the rack configuration supports the installed module before energizing the system.\u003c\/li\u003e\n\u003cli\u003eConnect the INFI-Net network interface according to the ABB system wiring documentation.\u003c\/li\u003e\n\u003cli\u003eConnect the Ethernet interface using the approved network topology and cabling specified for the host system.\u003c\/li\u003e\n\u003cli\u003eKeep Ethernet communication wiring separated from high-voltage power conductors and high-current switching circuits where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate cable shielding and grounding practices according to the ABB installation documentation and site electrical standards.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet addressing, network parameters, and host-system configuration before placing the communication path into service.\u003c\/li\u003e\n\u003cli\u003eConfirm the installed firmware revision before performing configuration or commissioning work.\u003c\/li\u003e\n\u003cli\u003eDo not infer unsupported hot-swap capability, power consumption, environmental limits, or network performance values from the module designation alone.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify INFI-Net communication and Ethernet host communication independently before returning the associated control system to normal operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44595694272600,"sku":"SPINIET800","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/SPINIET800-3_1200x1200_932e54ee-bf2b-43aa-94a9-0e9da9aac59f.jpg?v=1786702150","url":"https:\/\/www.industriaxplc.com\/id\/products\/abb-spiet800-infi-net-to-ethernet-transfer-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}