{"product_id":"abb-s800-i-o-di818-3bse069052r1-digital-input-module","title":"ABB S800 I\/O DI818 3BSE069052R1 Digital Input Module","description":"\u003ch2\u003eABB DI818 3BSE069052R1 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC digital signal acquisition in the ABB S800 I\/O system, the \u003cstrong\u003eABB DI818 3BSE069052R1\u003c\/strong\u003e (\u003cstrong\u003eDI818\u003c\/strong\u003e Digital Input Module) provides direct electrical input processing through 32 isolated channels for industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI818 3BSE069052R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003eIsolated in two groups of 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Type\u003c\/td\u003e\n\u003ctd\u003eDI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Termination Unit Compatibility\u003c\/td\u003e\n\u003ctd\u003eTU818, TU819, TU830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm depth x 119 mm height x 45 mm width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Classification\u003c\/td\u003e\n\u003ctd\u003eI-O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eCategory 5 Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Backplane and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DI818 integrates with the ABB S800 I\/O architecture through the module backplane communication interface. Therefore, the module supports high-density digital input deployment with 32 channels arranged into two electrically isolated groups of 16 channels.\u003c\/p\u003e\n\u003cp\u003eThe isolated channel grouping reduces signal interaction between field circuits and the control system. Additionally, the module termination units TU818, TU819, and TU830 provide the required field wiring interface for cabinet installation and signal distribution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are the DI818 input channels electrically organized?\u003cbr\u003eA: The DI818 contains 32 digital input channels divided into two isolated groups of 16 channels. Each group operates as an independent field signal section.\u003c\/p\u003e\n\u003cp\u003eQ: Which termination units support the DI818 module?\u003cbr\u003eA: The DI818 is designed for use with ABB TU818, TU819, and TU830 Module Termination Units for field connection.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DI818 be installed in systems requiring channel isolation?\u003cbr\u003eA: Yes. The module provides electrical isolation between the two groups of 16 input channels, supporting separated field signal wiring configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DI818 module on the compatible ABB S800 I\/O carrier according to ABB system installation procedures.\u003c\/li\u003e\n\u003cli\u003eVerify that the selected Module Termination Unit matches the field wiring requirements before connection.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level signal cables from high-voltage power wiring to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shields according to the cabinet grounding design and local electrical standards.\u003c\/li\u003e\n\u003cli\u003eConfirm the 24 VDC input wiring polarity before applying field power.\u003c\/li\u003e\n\u003cli\u003eCheck module status indicators after installation to verify correct communication and input operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619865423960,"sku":"DI818 3BSE069052R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI818-3BSE069052R1-3_1200x1200_4c741be6-1611-4eb6-b8b4-81dfd7cb7e75.jpg?v=1787047042","url":"https:\/\/www.industriaxplc.com\/id\/products\/abb-s800-i-o-di818-3bse069052r1-digital-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}