{"product_id":"abb-dos810-3bse078768r1-digital-output-signal-conditioning-module","title":"ABB DOS810 3BSE078768R1 Digital Output Signal Conditioning Module","description":"\u003ch2\u003eABB DOS810 3BSE078768R1 Digital Output Signal Conditioning Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DOS810 3BSE078768R1\u003c\/strong\u003e serves as the primary \u003cstrong\u003eDOS810\u003c\/strong\u003e Digital Output Signal Conditioning Module utilized to execute 24 V DC \/ 0.6 A output switching tasks across ABB Ability System 800xA Select I\/O platforms. The module provides one-channel signal conditioning, field device powering, diagnostics, redundancy support, and hot-swap capability for 2-wire devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDOS810 3BSE078768R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Signal Conditioning Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB Ability System 800xA Select I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e73 g including base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 77.9 mm, Depth 105 mm, Height 9.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.36 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Field Devices\u003c\/td\u003e\n\u003ctd\u003e2-wire devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation to system, factory routine tested at 3060 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power\u003c\/td\u003e\n\u003ctd\u003eCurrent limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Input Robustness\u003c\/td\u003e\n\u003ctd\u003e+\/-35 V between all terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e40 to 5000 ohm, maximum inductor time constant L\/R 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLoop supervision, internal hardware supervision, communication supervision, internal power supervision, power injection supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Installation\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS Barrier\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-4, IEC\/EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1-12, IEC\/EN 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DOS810 operates within the ABB Select I\/O architecture, where Ethernet networked I\/O modules separate field termination functions from controller-level configuration. Therefore, the module supports flexible cabinet design by allowing single-channel I\/O placement independent from traditional centralized marshalling structures.\u003c\/p\u003e\n\u003cp\u003eThe Select I\/O platform applies I\/O density scaling through distributed signal conditioning modules. Furthermore, the DOS810 supports redundant configurations and hot-swap replacement procedures to maintain system availability during maintenance activities.\u003c\/p\u003e\n\u003cp\u003eThe module performs digital output conditioning between the automation system and connected 2-wire field devices. It provides galvanic isolation between the system side and field side while maintaining supervised output operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB DOS810 support hot swapping during system operation?\u003cbr\u003eA: Yes. The DOS810 supports hot swap replacement within the Select I\/O architecture. Actual replacement procedures must follow ABB system maintenance instructions and application configuration requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field devices can connect to the DOS810?\u003cbr\u003eA: The DOS810 supports 2-wire field devices requiring a 24 V DC \/ 0.6 A digital output signal interface.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic functions are available on the DOS810?\u003cbr\u003eA: The module provides loop supervision for short circuit and open circuit conditions, internal hardware monitoring, communication supervision, internal power supervision, and power injection supervision.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DOS810 module within the ABB Select I\/O mechanical system according to the approved cabinet layout.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring matches the specified 24 V DC digital output requirements before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eMaintain correct separation between field signal wiring and high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shields according to the site grounding design and applicable EMC installation practices.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal wiring polarity before commissioning connected 2-wire devices.\u003c\/li\u003e\n\u003cli\u003eEnsure environmental conditions remain within the specified operating temperature, humidity, and pollution limits.\u003c\/li\u003e\n\u003cli\u003eUse approved hazardous area installation procedures when applying the module in classified locations.\u003c\/li\u003e\n\u003cli\u003ePerform loop supervision and output verification tests after installation completion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619130929240,"sku":"DOS810 3BSE078768R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DOS810-3BSE078768R1-2_1200x1200_50c7f99b-207c-46bc-80b8-c47f58b32813.jpg?v=1787037482","url":"https:\/\/www.industriaxplc.com\/id\/products\/abb-dos810-3bse078768r1-digital-output-signal-conditioning-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}