{"product_id":"abb-ci867k01-3bse043660r1-modbus-tcp-interface-kit-2","title":"ABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit","description":"\u003ch2\u003eABB CI867K01 3BSE043660R1 Modbus TCP Interface Kit\u003c\/h2\u003e\n\u003cp\u003eConfigured for Modbus TCP communication in ABB control system networks, the \u003cstrong\u003eABB CI867K01 3BSE043660R1\u003c\/strong\u003e (\u003cstrong\u003e3BSE043660R1\u003c\/strong\u003e Modbus TCP Interface Kit) provides a physical Ethernet interface for master and slave data exchange. The module uses one RJ-45 channel with 10\/100 Mbit\/s transmission and supports connection through the CEX bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI867K01 3BSE043660R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE043660R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus TCP Interface Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eMODBUS TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eMaster \/ Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s, Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEX Bus Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 12 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRJ-45 female, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 18.6 x 6.8 x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m according to IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Ethernet and ABB Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CI867K01 provides a single Ethernet communication channel for MODBUS TCP master and slave operation. Therefore, the RJ-45 interface handles network-level data exchange while the module connects to the ABB control architecture through the CEX bus.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet channel supports 10\/100 Mbit\/s transmission. In addition, the CEX bus supports a maximum of 12 units according to the supplied specification.\u003c\/p\u003e\n\u003cp\u003eFor ABB PLC and DCS installations, the module operates as an interface component rather than as a general-purpose Ethernet switch. Consequently, network addressing, Modbus TCP device configuration, and controller-side communication parameters must match the associated control-system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocol does the CI867K01 support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module supports MODBUS TCP communication through one RJ-45 Ethernet channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CI867K01 operate as both a Modbus TCP master and slave?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The supplied specification identifies the operating mode as Master \/ Slave.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the electrical supply and current consumption specifications?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data specifies 24 V supply voltage and 160 mA current consumption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the CI867K01 according to the applicable ABB control-system hardware documentation and cabinet requirements. Verify the module position and CEX bus configuration before energizing the system.\u003c\/p\u003e\n\u003cp\u003eUse an appropriate Ethernet cable for the RJ-45 interface and route communication wiring separately from high-voltage and high-current conductors where practical. Maintain proper cable shielding and grounding practices according to the site electrical design and ABB installation requirements.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify the 24 V supply polarity, voltage level, connector seating, CEX bus connections, and Ethernet link status. Configure the Modbus TCP network parameters consistently between the CI867K01 and connected devices.\u003c\/p\u003e\n\u003cp\u003eKeep the ambient operating temperature within 0 to +55 deg C and ensure that the installation altitude does not exceed the specified 2000 m limit.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44595710951512,"sku":"TU830V1 3BSE013234R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU830V1-3BSE013234R1-3_1200x1200_e6571310-08e6-4ec0-8235-5c1bc26a9955.jpg?v=1786703012","url":"https:\/\/www.industriaxplc.com\/id\/products\/abb-ci867k01-3bse043660r1-modbus-tcp-interface-kit-2","provider":"IndustriaX Limited","version":"1.0","type":"link"}