{"product_id":"abb-ac-800m-pm867k01-3bse076355r1-processor-modules","title":"ABB AC 800M PM867K01 3BSE076355R1 Processor Modules","description":"\u003ch2\u003eABB PM867K01 Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE076355R1 PM867K01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePM867K01\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for CPU execution, communication management, and safety control processing within ABB AC 800M High Integrity and System 800xA platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePM867K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE076355R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eAC 800M High Integrity \/ System 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eMPC866\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd\u003e0.09 ms per 1000 boolean operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Available for Application\u003c\/td\u003e\n\u003ctd\u003e46.559 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Storage\u003c\/td\u003e\n\u003ctd\u003e18 MB Flash PROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory for Storage\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1200 g including base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e119 mm width x 186 mm height x 135 mm depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2-30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e210 mA typical \/ 360 mA maximum at +24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.1 W typical \/ 8.6 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 Ethernet ports, IEEE 802.3, 10 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x RS-232C ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM3 Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232C, 75-19200 baud, RJ45, RTS-CTS support, non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM4 Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232C, 9600 baud, RJ45, optically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Network Protocol\u003c\/td\u003e\n\u003ctd\u003eMMS and IAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Network Backbone\u003c\/td\u003e\n\u003ctd\u003e100 Mbit\/s switched Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Applications\u003c\/td\u003e\n\u003ctd\u003eUp to 32 applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Application\u003c\/td\u003e\n\u003ctd\u003eUp to 64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagrams per Application\u003c\/td\u003e\n\u003ctd\u003eUp to 128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTasks per Controller\u003c\/td\u003e\n\u003ctd\u003eUp to 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Time\u003c\/td\u003e\n\u003ctd\u003eDown to 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEX-Bus Communication Modules\u003c\/td\u003e\n\u003ctd\u003eMaximum 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEX-Bus Supply Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 2.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulebus I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 96 I\/O modules with single CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant CPU I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 84 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Backup Battery\u003c\/td\u003e\n\u003ctd\u003eLithium 3.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock Stability\u003c\/td\u003e\n\u003ctd\u003e100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware, Redundancy and Industrial Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe PM867K01 CPU board integrates a microprocessor, RAM memory, real-time clock, LED indicators, INIT push button, and CompactFlash interface. The controller base plate provides two RJ45 Ethernet ports for Control Network communication and two RJ45 serial interfaces for configuration and service operations.\u003c\/p\u003e\n\u003cp\u003eThe PM867K01 supports CPU redundancy functions when configured with compatible redundancy components. The redundancy architecture covers CPU modules, CEX-Bus communication paths, communication interfaces, and S800 I\/O connections. The maximum controller switchover time in redundant configuration is 10 ms.\u003c\/p\u003e\n\u003cp\u003eABB AC 800M High Integrity functionality requires the addition of an SM812 safety module and SIL-certified software. Therefore, the controller supports IEC 61508 and TÜV-certified safety execution environments for combined safety and process control applications.\u003c\/p\u003e\n\u003cp\u003eThe module supports firmware flash compatibility within the AC 800M controller environment and provides deterministic backplane communication through the controller architecture. Furthermore, the I\/O density scaling supports electrical and optical Modulebus clusters for distributed S800 I\/O expansion.\u003c\/p\u003e\n\u003cp\u003eCompatibility applies to ABB 800xA version 6.0.2 and later systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the PM867K01 support CPU redundancy operation?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The PM867K01 supports CPU redundancy configurations with compatible redundancy components covering CPU, CEX-Bus, communication interfaces, and S800 I\/O connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication interfaces are integrated on the PM867K01 controller?\u003c\/strong\u003e\u003cbr\u003eA: The controller provides two Ethernet RJ45 ports for Control Network communication and two RS-232C RJ45 serial interfaces. COM3 supports modem control signals, while COM4 provides isolated configuration tool communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the PM867K01 suitable for SIL safety applications?\u003c\/strong\u003e\u003cbr\u003eA: Yes. High Integrity operation requires an SM812 module and SIL-certified software. The AC 800M High Integrity platform supports IEC 61508 and TÜV-certified safety control functions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the PM867K01 on the designated AC 800M controller base plate with correct mechanical alignment.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 V DC power supply polarity before energizing the controller.\u003c\/li\u003e\n\u003cli\u003eConnect Ethernet communication cables to CN1 and CN2 ports according to Control Network topology requirements.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication wiring where required by the industrial installation environment.\u003c\/li\u003e\n\u003cli\u003eKeep RS-232C service connections separated from high-voltage power wiring to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConfirm CEX-Bus and Modulebus connections before commissioning connected communication modules and S800 I\/O units.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for cabinet installation and follow ABB system installation documentation.\u003c\/li\u003e\n\u003cli\u003eVerify firmware and System 800xA compatibility before controller replacement or migration activities.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44650683465816,"sku":"PM867K01 3BSE076355R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/PM867K01-3BSE076355R1-3_1200x1200_4632de0a-2cd5-4768-8a91-95b6d34acdbf.jpg?v=1787564748","url":"https:\/\/www.industriaxplc.com\/id\/products\/abb-ac-800m-pm867k01-3bse076355r1-processor-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}