{"product_id":"a2sam105-h000-n-io-analog-input-adapter-yokogawa","title":"A2SAM105-H000 | N-IO Analog Input Adapter | Yokogawa","description":"\u003ch2\u003eYokogawa A2SAM105-H000 N-IO Analog Input Adapter\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal acquisition in Yokogawa CENTUM VP and ProSafe-RS platforms, the \u003cstrong\u003eYokogawa A2SAM105-H000\u003c\/strong\u003e (\u003cstrong\u003eA2SAM105 Analog Input Adapter\u003c\/strong\u003e) provides direct physical\/electrical execution of 4–20 mA and voltage signal interfacing to the N-IO baseplate backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA2SAM105-H000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact plug-in, baseplate mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via baseplate 5 V DC rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC, 1–5 V DC, 0–10 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Range\u003c\/td\u003e\n\u003ctd\u003e0–40 mA, 0–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e320 Ω @ 20 mA, 640 Ω @ 4 mA (powered); ≥100 kΩ (unpowered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±4 mV \/ ±12 μA @ 23±2 degC; ±8 mV \/ ±24 μA @ 0–60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 min (I\/O adaptors), 42 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen\/short circuit detection, internal self-test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSimplex or TMR compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eUp to SIL3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eHART 7 digital overlay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEach input channel maintains galvanic separation to prevent ground loop formation and minimize crosstalk. Isolation barriers sustain 500 V AC withstand ratings between adjacent channels and the backplane. This structure preserves measurement accuracy in electrically noisy environments and supports mixed current\/voltage input configurations without interaction between channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the A2SAM105-H000 support live replacement?\u003c\/p\u003e\n\u003cp\u003eA: No. The module must be de-energized before removal or insertion due to hard-wired field connections and baseplate power coupling.\u003c\/p\u003e\n\u003cp\u003eQ: What is the transmitter excitation voltage range?\u003c\/p\u003e\n\u003cp\u003eA: The adapter supplies 15.0 V DC minimum at 20 mA load, up to 24.0 V DC maximum at 0 mA load.\u003c\/p\u003e\n\u003cp\u003eQ: Can HART 7 data be accessed simultaneously with analog values?\u003c\/p\u003e\n\u003cp\u003eA: Yes. HART digital communication is superimposed on the analog loop without affecting 4–20 mA signal integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the adapter directly onto the designated N-IO baseplate until fully seated. Secure field wiring with proper torque on screw terminals. Route analog input cables separately from power conductors to reduce inductive interference. Connect shield drains to the central grounding point at the cabinet only. Verify all input ranges via software configuration prior to commissioning.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44203017896024,"sku":"A2SAM105-H000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/A2SAM105-H000-2.jpg?v=1780888052","url":"https:\/\/www.industriaxplc.com\/id\/products\/a2sam105-h000-n-io-analog-input-adapter-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}