{"product_id":"8u-taoxa1-analog-output-terminal-assembly-honeywell","title":"8U-TAOXA1 Analog Output Terminal Assembly | Honeywell","description":"\u003ch2\u003eHoneywell 8U-TAOXA1 Analog Output Terminal Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal termination in the Honeywell Experion PKS Series 8 I\/O system, the \u003cstrong\u003eHoneywell 8U-TAOXA1\u003c\/strong\u003e (\u003cstrong\u003e8U-TAOXA1\u003c\/strong\u003e Analog Output Terminal Assembly) provides direct field wiring interface and electrical connection execution between analog output modules and connected field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-TAOXA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive terminal assembly; no independent power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series 8 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Terminal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating Type\u003c\/td\u003e\n\u003ctd\u003eUncoated (Non-conformal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC analog output termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eSeries 8 I\/O carrier mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal or equivalent field wiring termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Support\u003c\/td\u003e\n\u003ctd\u003eHART pass-through when paired with compatible analog output modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Support\u003c\/td\u003e\n\u003ctd\u003eSupports replacement procedures within Series 8 I\/O architecture according to system installation requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Interface and Isolation Features\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8U-TAOXA1 provides the physical termination point for analog output loops connected to Experion PKS Series 8 I\/O modules. Therefore, the assembly maintains field wiring organization and signal routing between control modules and external actuators.\u003c\/p\u003e\n\u003cp\u003eWhen installed with compatible Honeywell analog output modules, the terminal assembly supports 4-20 mA HART loop protocol pass-through communication. In addition, the connected I\/O architecture provides channel-to-channel signal management according to the selected Series 8 module design.\u003c\/p\u003e\n\u003cp\u003eThe terminal assembly does not perform analog signal conversion or independent signal processing. Instead, it transfers electrical signals between the I\/O module terminals and field wiring connections while maintaining the specified cabinet wiring arrangement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 8U-TAOXA1 perform analog signal conversion?\u003c\/strong\u003e\u003cbr\u003eA: No. The 8U-TAOXA1 is a terminal assembly that provides field wiring termination. The associated Analog Output I\/O module performs signal generation and control processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 8U-TAOXA1 support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes. HART pass-through communication is available when the terminal assembly operates with a compatible Honeywell Series 8 Analog Output module supporting HART functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 8U-TAOXA1 suitable for redundant I\/O configurations?\u003c\/strong\u003e\u003cbr\u003eA: The terminal assembly can be installed within Series 8 I\/O configurations that support redundancy. The exact redundant wiring arrangement depends on the selected I\/O module and system design.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 8U-TAOXA1 on the designated Honeywell Series 8 I\/O carrier position according to the system hardware configuration.\u003c\/p\u003e\n\u003cp\u003eBefore wiring, verify the terminal assignment between the Analog Output module and the connected field device. Maintain correct polarity for 4-20 mA current loops to prevent signal inversion or loop faults.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation cable where required by the installation design. Connect cable shields according to the site grounding standard and avoid routing analog signal wiring parallel to high-current power cables.\u003c\/p\u003e\n\u003cp\u003eConfirm that field wiring insulation, terminal tightening, and cabinet grounding meet the applicable industrial control installation requirements before system commissioning.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44434360238168,"sku":"8U-TAOXA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/8U-TAOXA1-3.jpg?v=1784794212","url":"https:\/\/www.industriaxplc.com\/id\/products\/8u-taoxa1-analog-output-terminal-assembly-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}