{"product_id":"330908-12-31-10-02-00-bently-nevada-3300-nsv-proximity-probe","title":"330908-12-31-10-02-00 Bently Nevada 3300 NSv Proximity Probe","description":"\u003ch2\u003eBently Nevada 330908-12-31-10-02-00 3300 NSv Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330908-12-31-10-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330908\u003c\/strong\u003e 3300 NSv Proximity Probe, operates as a dedicated hardware component for eddy-current displacement measurement within the 3300 NSv Proximity Transducer System. The probe converts shaft target position changes into proportional voltage signals for vibration, position, and Keyphasor monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330908-12-31-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Eddy Current Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF thread; 1.2 in unthreaded length; 3.1 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-34 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered by compatible 3300 NSv Proximity Transducer System driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Configuration\u003c\/td\u003e\n\u003ctd\u003eWithout armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial cable with FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eEddy current displacement sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 12.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eApproximately -1 VDC to -13 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Body Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Target Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e11.3 N m (100 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy Current Probe Scaling and Rotor Dynamics Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv probe uses eddy-current sensing technology to measure shaft displacement relative to the probe tip. Therefore, the probe output follows a defined voltage displacement relationship with an incremental scale factor of 7.87 V\/mm.\u003c\/p\u003e\n\u003cp\u003eThe system supports rotor dynamics analysis by providing continuous shaft vibration and position feedback. In addition, the narrow side-view probe structure reduces side-wall interference when installed near small diameter targets, counterbores, and restricted bearing housings.\u003c\/p\u003e\n\u003cp\u003eGap voltage validation remains a key installation procedure for accurate measurement. The 3300 NSv system typically verifies probe gap voltage near the -10 VDC target position to confirm correct operating clearance and signal linearity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What measurement signals does the 330908-12-31-10-02-00 provide?\u003cbr\u003eA: The probe provides proportional voltage output related to shaft displacement and supports vibration, radial position, and Keyphasor measurement when connected to a compatible 3300 NSv driver system.\u003c\/p\u003e\n\u003cp\u003eQ: Can the probe operate without an extension cable?\u003cbr\u003eA: Yes. This model includes a 1.0 m integrated cable length. The final system configuration depends on the required distance between the probe and monitoring electronics.\u003c\/p\u003e\n\u003cp\u003eQ: What installation factors affect measurement accuracy?\u003cbr\u003eA: Proper probe gap adjustment, target material compatibility, cable routing, and electrical shielding practices directly affect displacement measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the probe with the specified 3\/8-24 UNF mounting thread and maintain proper mechanical alignment with the rotating shaft target surface.\u003c\/p\u003e\n\u003cp\u003eVerify the probe gap voltage after mechanical installation. Adjust the probe position until the operating voltage falls within the intended range for the 3300 NSv system.\u003c\/p\u003e\n\u003cp\u003eRoute the coaxial cable away from high-current power conductors and strong electromagnetic interference sources. Maintain proper cable shielding practices and connect the shield according to the monitoring system grounding requirements.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive cable bending near the ClickLoc connector area. Confirm that the probe tip faces the target material directly and that the mounting structure does not introduce mechanical movement during operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44407489331288,"sku":"330908-12-31-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330908-12-31-10-02-00-3.jpg?v=1784616380","url":"https:\/\/www.industriaxplc.com\/id\/products\/330908-12-31-10-02-00-bently-nevada-3300-nsv-proximity-probe","provider":"IndustriaX Limited","version":"1.0","type":"link"}