{"product_id":"200200-02-02-cn-bently-nevada-protim-r-din-rail-mount-module","title":"200200-02-02-CN Bently Nevada ProTIM-R DIN Rail Mount Module","description":"\u003ch2\u003eBently Nevada 200200-02-02-CN ProTIM-R DIN Rail Mount Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for dual thermocouple signal conditioning in the Trendmaster Pro online condition monitoring system, the \u003cstrong\u003eBently Nevada 200200-02-02-CN\u003c\/strong\u003e (\u003cstrong\u003e200200\u003c\/strong\u003e ProTIM-R DIN Rail Mount Module) provides direct physical and electrical execution for temperature measurement channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e200200-02-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Transducer Interface Module (ProTIM-R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eTrendmaster Pro Online Condition Monitoring System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2 independent configurable channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel AA Input\u003c\/td\u003e\n\u003ctd\u003eK-Type Thermocouple via 200125 temperature transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel BB Input\u003c\/td\u003e\n\u003ctd\u003eK-Type Thermocouple via 200125 temperature transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Voltage Input Range\u003c\/td\u003e\n\u003ctd\u003e+1 VDC to +5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Current Input Range\u003c\/td\u003e\n\u003ctd\u003e+4 mA to +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-18 deg C to +204 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-8 deg C including ProTIM-R, thermocouple, and lead wire error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.07 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lead Wire Length\u003c\/td\u003e\n\u003ctd\u003e6 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Temperature Ramp Rate\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5 deg C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Operating Range\u003c\/td\u003e\n\u003ctd\u003e-31 deg C to +213 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Rating\u003c\/td\u003e\n\u003ctd\u003e100% condensing on exposed surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Approval\u003c\/td\u003e\n\u003ctd\u003eNEPSI and ATEX\/IECEx option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Scaling and Temperature Channel Processing\u003c\/h3\u003e\n\u003cp\u003eThe ProTIM-R module processes field transducer signals through dedicated input conditioning circuits. Moreover, the dual-channel architecture allows independent measurement handling for two temperature inputs connected through 200125 temperature transducers.\u003c\/p\u003e\n\u003cp\u003eFor Bently Nevada monitoring systems, signal integrity depends on correct sensor scaling and electrical validation. Therefore, installation procedures must maintain proper signal reference conditions and minimize interference from external wiring sources. The module supports isolated temperature inputs to reduce ground loop effects during distributed machinery monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input devices are supported by the 200200-02-02-CN module?\u003cbr\u003eA: The module supports dual K-Type thermocouple inputs through 200125 temperature transducers. It processes two independent temperature measurement channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ProTIM-R module provide electrical isolation for temperature inputs?\u003cbr\u003eA: Yes. The temperature input channels include electrical isolation to reduce ground loop interference between field devices and monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental limits apply to the thermocouple ProTIM-R variant?\u003cbr\u003eA: The operating temperature range is -25 deg C to +85 deg C, while storage temperature ranges from -40 deg C to +100 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 200200-02-02-CN module on a compatible DIN rail and verify mechanical engagement before connecting field wiring. Ensure thermocouple wiring follows correct polarity and maintains separation from high-voltage power conductors.\u003c\/p\u003e\n\u003cp\u003eMoreover, apply suitable contact protection methods, including DC4 grease on connector contacts where specified, to reduce corrosion risks in exposed environments. Use proper cable routing practices to limit electromagnetic interference and avoid parallel runs with high-current cables.\u003c\/p\u003e\n\u003cp\u003eVerify channel configuration before commissioning. Confirm thermocouple signal response, wiring continuity, and monitoring system communication status before placing the module into operational service.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44375393763416,"sku":"200200-02-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/200200-02-02-CN-3.jpg?v=1784009704","url":"https:\/\/www.industriaxplc.com\/id\/products\/200200-02-02-cn-bently-nevada-protim-r-din-rail-mount-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}