{"product_id":"170aai14000-modicon-momentum-schneider-electric-analog-input-base","title":"170AAI14000 Modicon Momentum Schneider Electric Analog Input Base","description":"\u003ch2\u003eSchneider Electric 170AAI14000 Modicon Momentum Analog Input Base\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 170AAI14000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e170AAI14000\u003c\/strong\u003e Analog Input Base, operates as a dedicated hardware component for analog signal acquisition within the Modicon Momentum automation platform. It accepts voltage and current process signals, converts them into 16-bit signed data, and transfers measurement values to the controller through the Momentum I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e170AAI14000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Momentum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e16, single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, +\/- 5 V, +\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit conversion, 16-bit signed data format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2200 kOhm (voltage inputs), \u0026lt; 0.25 Ohm (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter\u003c\/td\u003e\n\u003ctd\u003eLow-pass, 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale\u003c\/td\u003e\n\u003ctd\u003e16 mA (4-20 mA), 5 V (+\/- 5 V), 10 V (+\/- 10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.15 % FS at 25 degC (voltage), +\/- 0.25 % FS at 25 degC (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e30 ppm FS\/degC (voltage), 60 ppm FS\/degC (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Ground Isolation\u003c\/td\u003e\n\u003ctd\u003e1780 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply-to-Ground Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible Common Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC, 47-63 Hz; 100 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Requirement\u003c\/td\u003e\n\u003ctd\u003e+\/- 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e305 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.55 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Protection\u003c\/td\u003e\n\u003ctd\u003e2 A slow-blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Fuse\u003c\/td\u003e\n\u003ctd\u003e500 mA fast-blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Indicators\u003c\/td\u003e\n\u003ctd\u003e16 channel status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eTwo removable terminal block connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e141.5 x 125 x 47.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.215 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, FM Class 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric manufacturing location not specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Backplane Communication and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe 170AAI14000 is designed for the Modicon Momentum distributed I\/O platform, where analog measurement data is transferred through the Momentum backplane interface to the controller. Sixteen single-ended analog input channels provide high I\/O density for distributed acquisition while maintaining independent channel status indication through front-panel LEDs. The module delivers a fixed 25 ms update period for cyclic analog data acquisition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support both voltage and current analog inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports +\/- 5 V, +\/- 10 V, and 4-20 mA analog input ranges. Input type selection is determined during system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is channel isolation provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides 1780 VAC isolation between input channels and ground for 1 minute, and 500 V isolation between the supply and ground. The supplied specification does not indicate channel-to-channel isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can field wiring be connected through removable terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module uses two removable terminal block connectors to simplify field wiring and module replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the configured input range matches the connected field instrument before applying power.\u003c\/li\u003e\n\u003cli\u003eRoute analog signal cables separately from motor power and high-current conductors to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding standard and avoid multiple shield grounding points unless specified by the control system design.\u003c\/li\u003e\n\u003cli\u003eConfirm that the external supply meets the specified +\/- 30 VDC requirement before energizing the module.\u003c\/li\u003e\n\u003cli\u003eInstall the specified external 500 mA fast-blow fuse and observe the internal protection limits during maintenance.\u003c\/li\u003e\n\u003cli\u003eMaintain ambient operating conditions within the specified temperature and humidity limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44278265905240,"sku":"170AAI14000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/170AAI14000-2.jpg?v=1782437114","url":"https:\/\/www.industriaxplc.com\/id\/products\/170aai14000-modicon-momentum-schneider-electric-analog-input-base","provider":"IndustriaX Limited","version":"1.0","type":"link"}