{"product_id":"170180-01-05-external-transducer-i-o-modules-bently-nevada","title":"170180-01-05 | External Transducer I\/O Modules Bently Nevada","description":"\u003ch2\u003eBently Nevada 170180-01-05 FieldMonitor External Transducer I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for dual-channel transducer signal acquisition in the FieldMonitor system, the \u003cstrong\u003eBently Nevada 170180-01-05\u003c\/strong\u003e (\u003cstrong\u003e170180\u003c\/strong\u003e FieldMonitor External Transducer I\/O Module) provides direct physical and electrical interface execution for -24 VDC Proximitor or accelerometer inputs. This module is also cataloged as Solar Part Number 1034549-80.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e170180-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eFieldMonitor External Transducer I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExternal Transducer I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.60 lbs (272 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.1 cm x 19 cm x 12.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 20 mA input current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e2 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003eSupports up to two transducer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel A Input\u003c\/td\u003e\n\u003ctd\u003e-24 VDC Proximitor or accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel B Input\u003c\/td\u003e\n\u003ctd\u003e-24 VDC Proximitor or accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Base Occupancy\u003c\/td\u003e\n\u003ctd\u003eOne FieldMonitor Terminal Base slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration and static position measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50081-2, EN 50082-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 170180-01-05 processes proximity and accelerometer signals through two independent input channels. Therefore, each channel maintains separate signal conditioning paths for connected transducers.\u003c\/p\u003e\n\u003cp\u003eThe module supports -24 VDC Proximitor operation and allows FieldMonitor systems to acquire vibration and displacement-related signals. In addition, eddy-current probe scaling functions maintain the relationship between probe output voltage and mechanical shaft position measurements.\u003c\/p\u003e\n\u003cp\u003eFor proximity measurement applications, gap voltage validation uses the typical Bently Nevada -10 VDC target reference for probe operating condition verification. The module architecture supports accurate rotor dynamics monitoring by preserving vibration waveform characteristics and reducing signal interference between measurement channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many transducer inputs can the Bently Nevada 170180-01-05 accept?\u003cbr\u003eA: The module provides two independent input channels and accepts up to two transducer inputs through Channel A and Channel B.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 170180-01-05 support both Proximitor and accelerometer inputs?\u003cbr\u003eA: Yes. Each channel supports -24 VDC Proximitor or accelerometer signal inputs according to the configured measurement application.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module require a dedicated FieldMonitor Terminal Base position?\u003cbr\u003eA: Yes. The 170180-01-05 occupies one slot within a FieldMonitor Terminal Base for mechanical installation and electrical connection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module only in a compatible FieldMonitor Terminal Base slot.\u003c\/li\u003e\n\u003cli\u003eVerify channel configuration before connecting field transducers.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation wiring for vibration and displacement signal connections.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to site grounding practices to reduce electrical noise.\u003c\/li\u003e\n\u003cli\u003eSeparate transducer signal wiring from high-current power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm Proximitor supply polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eCheck sensor wiring continuity and insulation resistance before system startup.\u003c\/li\u003e\n\u003cli\u003eVerify gap voltage readings after installation to confirm correct probe positioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44387526770776,"sku":"170180-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/170180-01-05-3.jpg?v=1784186647","url":"https:\/\/www.industriaxplc.com\/id\/products\/170180-01-05-external-transducer-i-o-modules-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}