{"product_id":"16699-01-02-02-seismoprobe-velocity-transducer-bently-nevada","title":"16699-01-02-02 | Seismoprobe Velocity Transducer| Bently Nevada","description":"\u003ch2\u003eBently Nevada 16699-01-02-02 \u003cspan style=\"text-decoration: underline;\"\u003eSeismoprobe Velocity Transducer\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 16699-01-02-02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e16699\u003c\/strong\u003e Seismoprobe Velocity Transducer, operates as a dedicated hardware component for converting absolute casing and bearing housing vibration into proportional voltage signals within machinery protection and condition monitoring networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eOption Type\u003c\/th\u003e\n\u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e16699\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSeismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eSensitivity Option\u003c\/td\u003e\n\u003ctd\u003e500 mV\/in\/sec (19.7 mV\/mm\/sec) standard sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-02\u003c\/td\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003eStud-mount version (1\/4-28 UNF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-02\u003c\/td\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003eStandard MIL-C-5015 2-pin top-exit connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16699-01-02-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g (0.55 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e63.5 mm diameter x 101.6 mm length (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-29 deg C to 100 deg C (-20 deg F to 212 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Self-generating, no external power required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eMoving-Coil Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e500 mV\/in\/sec (19.7 mV\/mm\/sec) +\/- 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e270 to 60,000 CPM (4.5 Hz to 1,000 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResonant Frequency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 4.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e350 Ohm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransverse Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 % of axial sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF threaded stud mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 16699 series transducers are optimized for rotor dynamics analysis by maintaining linear output characteristics within the defined frequency band. The moving-coil design minimizes eddy-current interference and supports cross-talk suppression when multiple units are installed in close proximity. Gap voltage validation is not applicable due to the passive nature of the device; however, baseline bias checks against known vibration sources are recommended to confirm coil integrity prior to integration into 3500 series monitoring racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 16699-01-02-02 support hot-swap replacement in live machinery protection systems?\u003c\/p\u003e\n\u003cp\u003eA: No. Although the sensor is passive, removal or installation under vibration conditions can induce transient voltages that may affect monitoring system thresholds. Perform replacement during scheduled outages.\u003c\/p\u003e\n\u003cp\u003eQ: What is the minimum bending radius for the interconnecting cable to avoid signal attenuation?\u003c\/p\u003e\n\u003cp\u003eA: Maintain a cable bend radius of at least 50 mm to prevent mechanical stress on the MIL-C-5015 connector and internal conductor displacement.\u003c\/p\u003e\n\u003cp\u003eQ: Is calibration required after replacing the transducer?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Recalibrate the monitoring system channel using a known vibration reference source to ensure measurement accuracy within the stated +\/- 5 % sensitivity tolerance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the transducer using the 1\/4-28 UNF stud with a torque specification of 3.4 Nm (30 in-lb). Ensure the mounting surface is clean and flat to maintain full thread engagement. Orient the unit vertically or at the specified angle (90 deg +\/- 2.5 deg) relative to the vibration axis. Use proper shielded cable practices and ground the shield at one point only, preferably at the monitoring system end, to prevent ground loops. Avoid routing signal cables in parallel with high-voltage power lines to reduce electromagnetic interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44319509676120,"sku":"16699-01-02-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/16699-01-02-02-3.jpg?v=1783067166","url":"https:\/\/www.industriaxplc.com\/id\/products\/16699-01-02-02-seismoprobe-velocity-transducer-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}