{"product_id":"140cpu67160s-schneider-electric-unity-safety-processor","title":"140CPU67160S Schneider Electric Unity Safety Processor","description":"\u003ch2\u003eSchneider Electric 140CPU67160S Unity Safety Processor\u003c\/h2\u003e\n\u003cp\u003eConfigured for Hot Standby safety control in the Modicon Quantum automation platform, the \u003cstrong\u003eSchneider Electric 140CPU67160S\u003c\/strong\u003e (\u003cstrong\u003e140CPU67160\u003c\/strong\u003e Unity Safety Processor) provides direct physical and communication execution for redundant PLC architectures. The module integrates CPU processing, memory management, Ethernet connectivity, Modbus communication, and Hot Standby synchronization for deterministic controller operation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies \u003cstrong\u003e140CPU67160S\u003c\/strong\u003e as the complete ordering reference and \u003cstrong\u003e140CPU67160\u003c\/strong\u003e as the base processor model. No official suffix definition or ordering matrix is provided in the available technical data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140CPU67160S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUnity Safety Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eUnity Pro XL Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Frequency\u003c\/td\u003e\n\u003ctd\u003e266 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e1024 kB Internal RAM (512 kB Data Memory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003e3 VDC Lithium Battery (990XCP98000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e1200 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Service Life\u003c\/td\u003e\n\u003ctd\u003eUp to 10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Local Racks\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Rack Sizes\u003c\/td\u003e\n\u003ctd\u003e2, 3, 4, 6, 10, 16 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Stations\u003c\/td\u003e\n\u003ctd\u003eUp to 31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Remote Discrete I\/O\u003c\/td\u003e\n\u003ctd\u003e31,744 Inputs \/ 31,744 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Remote Analog I\/O\u003c\/td\u003e\n\u003ctd\u003e1,984 Inputs \/ 1,984 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Ethernet Modules\u003c\/td\u003e\n\u003ctd\u003eUp to 6 x 140NOE77111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP, Modbus, Modbus Plus, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connections\u003c\/td\u003e\n\u003ctd\u003e1 Local Ethernet TCP\/IP, 1 Hot Standby Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Connections\u003c\/td\u003e\n\u003ctd\u003e1 Local Modbus, 1 RS232\/485 Modbus ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Connections\u003c\/td\u003e\n\u003ctd\u003e1 USB Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD, 2 x 16 Characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Time (Word)\u003c\/td\u003e\n\u003ctd\u003e0.09 to 0.12 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Time (Boolean)\u003c\/td\u003e\n\u003ctd\u003e0.105 to 0.15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed-Point Arithmetic\u003c\/td\u003e\n\u003ctd\u003e0.96 to 1.02 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 K Instruction Execution\u003c\/td\u003e\n\u003ctd\u003e5.03 us (65 % Boolean, 35 % Numerical); 5.14 us (100 % Boolean)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Overhead\u003c\/td\u003e\n\u003ctd\u003e1.5 ms Master Task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e2500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e3 VDC (Lithium Battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Function\u003c\/td\u003e\n\u003ctd\u003eKey Switch, Memory Port On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Indicators\u003c\/td\u003e\n\u003ctd\u003eEthernet COM LED, Ethernet ERR LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003eUSB Type B, Dual RJ45, 9-pin Sub-D Modbus Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, C-Tick, TÜV Rheinland SIL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBus Current 2500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe processor exchanges controller data through the Modicon Quantum backplane while supporting Hot Standby synchronization using dedicated Ethernet communication with the 140NOE77111 module. Firmware compatibility should be maintained between redundant CPUs and associated communication modules before commissioning or processor replacement. During maintenance, processor firmware revisions should be verified to avoid synchronization mismatches within redundant controller pairs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can local I\/O modules be used in a Hot Standby application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications state that local discrete and analog I\/O expansion is not permitted for Hot Standby applications. Remote I\/O architecture is intended for redundant operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the processor include integrated communication interfaces?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The processor provides integrated Ethernet TCP\/IP, Modbus, Modbus Plus, and USB interfaces. Additional Ethernet capability can be expanded with up to six 140NOE77111 communication modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is processor memory retained during power removal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Internal memory retention is supported by the specified 3 VDC lithium backup battery. Battery condition should be checked during scheduled maintenance to maintain memory retention.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the processor only after confirming compatibility with the Modicon Quantum rack and power supply.\u003c\/li\u003e\n\u003cli\u003eVerify the key switch position before downloading or modifying the application program.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables where specified by the installation manual, and terminate cable shields according to the site grounding standard.\u003c\/li\u003e\n\u003cli\u003eEnsure Hot Standby processor pairs operate with matching firmware revisions before enabling redundancy.\u003c\/li\u003e\n\u003cli\u003eConfirm adequate backplane current capacity when adding communication modules to the rack.\u003c\/li\u003e\n\u003cli\u003eReplace the lithium backup battery only in accordance with the manufacturer's maintenance procedure to prevent unintended memory loss.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44278274490456,"sku":"140CPU67160S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/140CPU67160S-3.jpg?v=1782437273","url":"https:\/\/www.industriaxplc.com\/id\/products\/140cpu67160s-schneider-electric-unity-safety-processor","provider":"IndustriaX Limited","version":"1.0","type":"link"}