{"title":"System 800xA S800 AC800M","description":null,"products":[{"product_id":"abb-advant-s800-i-o-tu840-3bse020846r1-termination-unit","title":"ABB Advant S800 I\/O TU840 3BSE020846R1 Termination Unit","description":"\u003ch2\u003eABB TU840 3BSE020846R1 Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for redundant I\/O termination in the ABB Modulebus architecture, the \u003cstrong\u003eABB TU840 3BSE020846R1\u003c\/strong\u003e (\u003cstrong\u003eTU840\u003c\/strong\u003e Termination Unit) provides the physical and electrical interface for a 1+1 TB840 configuration. It includes a power supply connector and TB807 Modulebus terminator interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU840 3BSE020846R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTU840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE020846R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 18.5 x 12.2 x 4.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFor 1+1 TB840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSupports redundant I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModulebus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulebus Current Distribution\u003c\/td\u003e\n\u003ctd\u003eMaximum 5 V, 1.5 A; 24 V, 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Keys\u003c\/td\u003e\n\u003ctd\u003e36 different combinations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C; approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Modulebus and Redundant I\/O Interface\u003c\/h3\u003e\n\u003cp\u003eThe TU840 terminates and distributes electrical connections associated with a 1+1 TB840 redundant I\/O arrangement. The unit provides a dedicated power supply connector and accepts the TB807 Modulebus terminator.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the specified Modulebus current distribution reaches 1.5 A at 5 V and 1.5 A at 24 V. Therefore, installation planning should keep the connected module load within these stated distribution limits.\u003c\/p\u003e\n\u003cp\u003eThe mechanical keying system provides 36 different combinations. This feature controls physical module positioning and helps prevent incompatible module or termination-unit combinations during installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What TB840 configuration does the TU840 support?\u003cbr\u003eA: The TU840 is specified for a 1+1 TB840 configuration and supports redundant I\/O.\u003c\/p\u003e\n\u003cp\u003eQ: What power distribution does the TU840 provide?\u003cbr\u003eA: The specified maximum Modulebus current distribution is 1.5 A at 5 V and 1.5 A at 24 V.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting orientations are permitted?\u003cbr\u003eA: The supplied specification permits both vertical and horizontal mounting.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the complete part number \u003cstrong\u003eTU840 3BSE020846R1\u003c\/strong\u003e before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the termination unit matches the intended 1+1 TB840 redundant configuration.\u003c\/li\u003e\n\u003cli\u003eInstall the unit in the specified vertical or horizontal orientation.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC power input with correct polarity and suitable industrial wiring practices.\u003c\/li\u003e\n\u003cli\u003eKeep the connected Modulebus load within the specified 5 V and 24 V current distribution limits.\u003c\/li\u003e\n\u003cli\u003eInstall the TB807 Modulebus terminator at the designated interface.\u003c\/li\u003e\n\u003cli\u003eUse the mechanical keying arrangement to prevent an incorrect module combination.\u003c\/li\u003e\n\u003cli\u003eRoute power and communication wiring to minimize unnecessary coupling with high-current or high-noise conductors.\u003c\/li\u003e\n\u003cli\u003eVerify terminal tightness and connector seating before energizing the assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installation environment remains within the specified temperature and humidity limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612498620504,"sku":"TU840 3BSE020846R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU840-3BSE020846R1-3_1200x1200_1aa359f0-9fdf-4de9-a149-ba41af2a08a4.jpg?v=1786956778"},{"product_id":"abb-advant-s800-i-o-tu839-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU839 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU839 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TU839 3BSE046966R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTU839\u003c\/strong\u003e Extended Module Termination Unit, distributes ModuleBus signals to the installed I\/O module and the next MTU while providing eight I\/O channels and two isolated sensor-power groups.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU839\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE046966R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connections\u003c\/td\u003e\n\u003ctd\u003e2 connections per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e28 total; 8 I\/O channels plus 2 x 6 process power terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Distribution\u003c\/td\u003e\n\u003ctd\u003e2 individually isolated groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Fuse\u003c\/td\u003e\n\u003ctd\u003e200 mA per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Process Connection\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Compatibility\u003c\/td\u003e\n\u003ctd\u003eDI820, DI821, DI825\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Distribution\u003c\/td\u003e\n\u003ctd\u003eTo the I\/O module and the next MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Generation\u003c\/td\u003e\n\u003ctd\u003eOutgoing position signals shifted to the next MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Direction\u003c\/td\u003e\n\u003ctd\u003eBoth directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIN Rail Retention\u003c\/td\u003e\n\u003ctd\u003eMechanical latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Keying\u003c\/td\u003e\n\u003ctd\u003e2 keys, 6 positions each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Configurations\u003c\/td\u003e\n\u003ctd\u003e36 possible mechanical configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Wire Size\u003c\/td\u003e\n\u003ctd\u003eStranded: 24-14 AWG; 0.2-2.5 mm2 solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2300 V AC channel to ground; 1350 V AC channel to channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C; approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60664-1, EN 50178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I according to IEC 61140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50581:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDIRECTIVE\/2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e126 mm including connector; 120.5 mm edge to edge installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e64 mm including terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModuleBus Distribution and Mechanical Addressing\u003c\/h3\u003e\n\u003cp\u003eThe TU839 distributes the ModuleBus from the I\/O module to the following MTU. It also generates the I\/O module address by shifting the outgoing position signals toward the next MTU.\u003c\/p\u003e\n\u003cp\u003eTwo mechanical keys configure the MTU for different I\/O module types. Each key provides six selectable positions, resulting in 36 possible mechanical configurations. This keying function provides physical configuration only and does not change the electrical functionality of the MTU or I\/O module.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the MTU uses a mechanical DIN rail latch for retention. Installers can mount the unit on a standard DIN rail in either supported direction.\u003c\/p\u003e\n\u003ch3\u003eSensor Power Distribution\u003c\/h3\u003e\n\u003cp\u003eThe TU839 provides two individually isolated process-voltage groups for sensor power distribution. Each group incorporates a 200 mA fuse.\u003c\/p\u003e\n\u003cp\u003eEach of the eight I\/O channels provides two I\/O connections. The channel rating permits a maximum current of 1 A, while the maximum process-connection current is specified as 10 A.\u003c\/p\u003e\n\u003cp\u003eThe fuse rating should match the actual application load and connected sensor requirements. Do not select the fuse solely from the maximum channel rating.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels does the TU839 support?\u003cbr\u003eA: The TU839 supports up to 8 I\/O channels, with 2 I\/O connections assigned to each channel.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TU839 generate the I\/O module address?\u003cbr\u003eA: The MTU shifts the outgoing position signals to the next MTU, thereby generating the corresponding I\/O module address.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the two mechanical keys?\u003cbr\u003eA: The keys provide physical configuration for different I\/O module types. Each key has 6 positions, creating 36 possible mechanical configurations without changing MTU functionality.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU839 on a compatible standard DIN rail and engage the mechanical latch fully.\u003c\/li\u003e\n\u003cli\u003eVerify the mechanical key positions before installing the associated I\/O module.\u003c\/li\u003e\n\u003cli\u003eConnect the ModuleBus according to the intended MTU sequence and verify the outgoing connection toward the next MTU.\u003c\/li\u003e\n\u003cli\u003eSeparate process wiring from high-energy switching and power conductors where practical to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eMaintain correct polarity and termination for all connected process circuits.\u003c\/li\u003e\n\u003cli\u003eSelect the sensor-power fuse rating according to the actual application load and circuit requirements.\u003c\/li\u003e\n\u003cli\u003eKeep the two sensor-power groups electrically separated as specified by the installation design.\u003c\/li\u003e\n\u003cli\u003eUse acceptable conductor sizes from 24-14 AWG or 0.2-2.5 mm2.\u003c\/li\u003e\n\u003cli\u003eApply the specified 0.5 Nm terminal torque when terminating field wiring.\u003c\/li\u003e\n\u003cli\u003eVerify protective earth and enclosure arrangements according to the applicable installation standard.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installation remains within the specified 0 to +55 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eMaintain the IP20 protection requirements of the installed assembly.\u003c\/li\u003e\n\u003cli\u003eInspect channel-to-ground and channel-to-channel insulation requirements before energizing the process connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612506910808,"sku":"TU839","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU839-3_1200x1200_2368f43c-1084-4693-a850-9482aa728fdf.jpg?v=1786956929"},{"product_id":"abb-advant-s800-i-o-tu838-3bse008572r1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU838 3BSE008572R1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU838 3BSE008572R1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for direct field termination and process connection distribution, the \u003cstrong\u003eABB TU838 3BSE008572R1\u003c\/strong\u003e (\u003cstrong\u003eTU838\u003c\/strong\u003e Extended Module Termination Unit) provides physical I\/O termination for ABB automation systems. It supports 16 channels, 50 V rated voltage, and up to 3 A per I\/O channel. The unit uses terminal block connections and supports mounting in both directions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU838 3BSE008572R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 12.7 x 7.6 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C; approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBoth directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current at Process Connection\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB I\/O Termination and Channel Density\u003c\/h3\u003e\n\u003cp\u003eThe TU838 provides 16 physical I\/O channels through terminal block connections. Therefore, the unit accommodates a relatively high number of field connections within its extended termination configuration. Each I\/O channel permits a maximum current of 3 A, while the process connection has a maximum current rating of 10 A.\u003c\/p\u003e\n\u003cp\u003eThe 50 V rating defines the stated process-side voltage limit. In addition, the 500 V AC dielectric test voltage specifies the supplied insulation test level. The single I\/O configuration does not indicate a redundant termination arrangement in the supplied specifications.\u003c\/p\u003e\n\u003cp\u003eThe unit supports mounting in both directions, which allows the installer to select the orientation appropriate to the cabinet or mounting arrangement. Marine approvals include ABS, BV, DNV-GL, and LR.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels does the ABB TU838 provide?\u003c\/p\u003e\n\u003cp\u003eA: The TU838 provides 16 I\/O channels through terminal block connections.\u003c\/p\u003e\n\u003cp\u003eQ: What current can each I\/O channel handle?\u003c\/p\u003e\n\u003cp\u003eA: Each I\/O channel has a maximum specified current of 3 A. The maximum current at the process connection is 10 A.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental temperature range does the TU838 support?\u003c\/p\u003e\n\u003cp\u003eA: The specified operating range is 0 to +55 deg C. Storage temperature ranges from -40 to +70 deg C. Approval conditions are specified for +5 to +55 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the TU838 in the specified cabinet or mounting location with adequate mechanical support. Verify terminal identification before connecting field wiring, and keep signal wiring separated from high-voltage or high-current conductors where applicable.\u003c\/p\u003e\n\u003cp\u003eUse wiring and protective devices suitable for the connected load and the stated 50 V rating. Do not exceed the 3 A maximum current per I\/O channel or the 10 A process connection limit.\u003c\/p\u003e\n\u003cp\u003eMaintain appropriate separation between signal conductors and power conductors to reduce electromagnetic interference. Where shielded cables are used, terminate shields according to the system grounding design and avoid unintended ground loops.\u003c\/p\u003e\n\u003cp\u003eBefore energization, inspect terminal tightness, conductor routing, polarity, and insulation condition. Confirm that the installed temperature and humidity conditions remain within the specified operating limits.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612513398872,"sku":"TU838 3BSE008572R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU838-3BSE008572R1-3_1200x1200_91dd370c-c68a-48c8-b2c2-46f375e808c0.jpg?v=1786957009"},{"product_id":"abb-advant-s800-i-o-tu837v1-3bse013238r1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU837V1 3BSE013238R1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU837V1 3BSE013238R1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for ModuleBus distribution, I\/O addressing, and field terminal interfacing, the \u003cstrong\u003eABB TU837V1 3BSE013238R1\u003c\/strong\u003e (\u003cstrong\u003eTU837V1\u003c\/strong\u003e Extended Module Termination Unit) provides the physical connection between compatible S800 I\/O modules and process wiring. It supports up to 8 I\/O channels, with a maximum rated voltage of 250 V and maximum current of 3 A per channel.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU837V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE013238R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Process Connection\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e28; up to 8 I\/O channels with 2 terminals per channel; 2 x 6 power common terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O\u003c\/td\u003e\n\u003ctd\u003eDO820, DO821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Function\u003c\/td\u003e\n\u003ctd\u003eDistributes ModuleBus to the I\/O module and next MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Function\u003c\/td\u003e\n\u003ctd\u003eGenerates the I\/O module address by shifting outgoing position signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail, both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Latch\u003c\/td\u003e\n\u003ctd\u003eDIN rail locking latch, screwdriver release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Keys\u003c\/td\u003e\n\u003ctd\u003e2 keys, 6 positions each; 36 possible configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e126 mm W x 64 mm D x 110 mm H, including connectors and terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstalled Width\u003c\/td\u003e\n\u003ctd\u003e120.5 mm edge to edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C; approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60664-1, EN 50178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I according to IEC 61140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50581:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModuleBus Distribution and I\/O Addressing\u003c\/h3\u003e\n\u003cp\u003eThe TU837V1 distributes the ModuleBus from the connected I\/O module toward the next MTU. It also generates the correct module address through mechanical position signaling.\u003c\/p\u003e\n\u003cp\u003eThe MTU shifts outgoing position signals to the next termination unit. Therefore, the physical MTU position contributes to the I\/O module addressing sequence.\u003c\/p\u003e\n\u003cp\u003eThe unit supports up to 8 I\/O channels and provides two terminals per channel. Additionally, two groups of six power common terminals support the specified process connection arrangement.\u003c\/p\u003e\n\u003cp\u003eThe TU837V1 uses two mechanical configuration keys. Each key provides six selectable positions, producing 36 possible mechanical configurations. These keys identify the intended I\/O module arrangement mechanically and do not alter the electrical functionality of the MTU or I\/O module.\u003c\/p\u003e\n\u003ch3\u003eMechanical Installation and Wiring\u003c\/h3\u003e\n\u003cp\u003eThe MTU mounts directly on a standard DIN rail. A mechanical latch secures the unit to the rail, while a screwdriver releases the latch during removal.\u003c\/p\u003e\n\u003cp\u003eFor signal wiring, the specified conductor ranges are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolid signal conductor: 0.2 to 6 mm2\u003c\/li\u003e\n\u003cli\u003eStranded signal conductor: 0.2 to 4 mm2\u003c\/li\u003e\n\u003cli\u003eSignal conductor range: 24 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eSignal terminal torque: 0.5 to 0.6 Nm\u003c\/li\u003e\n\u003cli\u003eSignal stripping length: 8 mm\u003c\/li\u003e\n\u003cli\u003eSolid return conductor: 0.2 to 4 mm2\u003c\/li\u003e\n\u003cli\u003eStranded return conductor: 0.2 to 2.5 mm2\u003c\/li\u003e\n\u003cli\u003eReturn conductor range: 24 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eReturn terminal torque: 0.5 to 0.6 Nm\u003c\/li\u003e\n\u003cli\u003eReturn stripping length: 7 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels does the TU837V1 support?\u003c\/p\u003e\n\u003cp\u003eA: The TU837V1 supports up to 8 I\/O channels, with a maximum rated current of 3 A per channel.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TU837V1 generate the I\/O module address?\u003c\/p\u003e\n\u003cp\u003eA: The MTU shifts outgoing position signals to the next MTU, thereby generating the correct address according to its physical position.\u003c\/p\u003e\n\u003cp\u003eQ: Do the two mechanical keys change the electrical operation of the I\/O module?\u003c\/p\u003e\n\u003cp\u003eA: No. The two keys provide mechanical configuration only. Each key has six positions, giving 36 possible mechanical configurations without changing electrical functionality.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TU837V1 on a compatible standard DIN rail and verify that the mechanical latch fully engages.\u003c\/li\u003e\n\u003cli\u003eRelease the DIN rail latch with a screwdriver when removing the MTU.\u003c\/li\u003e\n\u003cli\u003eConfigure the two mechanical keys according to the intended I\/O module arrangement.\u003c\/li\u003e\n\u003cli\u003eVerify the selected key positions before installing the compatible I\/O module.\u003c\/li\u003e\n\u003cli\u003eConnect signal and return conductors within the specified conductor-size ranges.\u003c\/li\u003e\n\u003cli\u003eApply 0.5 to 0.6 Nm terminal torque to the specified signal and return connections.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified stripping lengths of 8 mm for signal connections and 7 mm for return connections.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring separately from high-energy switching conductors where the installation requires noise reduction.\u003c\/li\u003e\n\u003cli\u003eVerify the ModuleBus connection between the I\/O module, TU837V1, and adjacent MTU before energizing the assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installation environment remains within the specified temperature, humidity, pollution, EMC, and IP20 conditions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612518314072,"sku":"TU837V1 3BSE013238R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU837V1-3BSE013238R1-3_1200x1200_628d5566-f16d-4988-bf4c-5050806f0b74.jpg?v=1786957120"},{"product_id":"abb-advant-s800-i-o-tu837-tu837v1-s800-i-o-module-termination-unit","title":"ABB Advant S800 I\/O TU837 \/ TU837V1 S800 I\/O Module Termination Unit","description":"\u003ch2\u003eABB TU837 \/ TU837V1 S800 I\/O Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for field signal termination and ModuleBus interconnection in the ABB S800 I\/O system, the \u003cstrong\u003eABB TU837V1\u003c\/strong\u003e (\u003cstrong\u003eTU837\u003c\/strong\u003e Module Termination Unit) provides direct electrical termination between field wiring and the installed I\/O module. The unit supports DIN rail mounting and defined conductor sizes for signal and return connections.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU837 \/ TU837V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit (MTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eField signal termination and ModuleBus interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Connection, Solid Wire\u003c\/td\u003e\n\u003ctd\u003e0.2 - 6 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Connection, Stranded Wire\u003c\/td\u003e\n\u003ctd\u003e0.2 - 4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Connection, Solid Wire\u003c\/td\u003e\n\u003ctd\u003e0.2 - 4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Connection, Stranded Wire\u003c\/td\u003e\n\u003ctd\u003e0.2 - 2.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Wire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Wire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 - 0.6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O ModuleBus and Termination Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TU837V1 provides the physical termination interface between field conductors and the associated S800 I\/O module. It also participates in the ModuleBus connection through the MTU assembly.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the termination unit separates field wiring operations from the electronic I\/O module interface. This arrangement allows technicians to perform module replacement without removing the field conductors where the installed S800 I\/O configuration supports hot-swap operation.\u003c\/p\u003e\n\u003cp\u003eThe TU837V1 accepts solid signal conductors from 0.2 - 6 mm2 and stranded signal conductors from 0.2 - 4 mm2. Return terminals accept solid conductors from 0.2 - 4 mm2 and stranded conductors from 0.2 - 2.5 mm2.\u003c\/p\u003e\n\u003cp\u003eThe DIN rail mounting arrangement supports horizontal or vertical cabinet installation. Therefore, cabinet layout can accommodate the MTU according to available wiring access and module orientation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What conductor sizes does the TU837V1 support for signal wiring?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The signal terminals accept 0.2 - 6 mm2 solid wire and 0.2 - 4 mm2 stranded wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What screw torque should technicians apply to the TU837V1 terminals?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification recommends a screw torque of 0.5 - 0.6 Nm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TU837V1 consume electrical power?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data does not specify power consumption. The TU837V1 functions as a passive Module Termination Unit rather than an electronic I\/O processing module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU837V1 securely on the specified DIN rail before connecting field conductors.\u003c\/li\u003e\n\u003cli\u003eVerify the installed MTU and I\/O module combination against the S800 I\/O system configuration.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring separately from high-voltage or high-current conductors where cabinet design permits.\u003c\/li\u003e\n\u003cli\u003eStrip signal conductors to 8 mm and return conductors to 7 mm before terminal insertion.\u003c\/li\u003e\n\u003cli\u003eApply 0.5 - 0.6 Nm terminal torque according to the supplied specification.\u003c\/li\u003e\n\u003cli\u003eEnsure each conductor is fully seated and mechanically secured before commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate segregation between signal, power, and grounding conductors.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the system grounding design and applicable cabinet wiring practices.\u003c\/li\u003e\n\u003cli\u003eConfirm that the terminal arrangement matches the assigned I\/O channel before energizing the field circuit.\u003c\/li\u003e\n\u003cli\u003eInspect the IP20 enclosure condition and terminal area after installation.\u003c\/li\u003e\n\u003cli\u003eDo not infer hot-swap capability solely from the MTU design; verify the complete S800 I\/O configuration and applicable module documentation before live replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612524245080,"sku":"TU837","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU837-3_1200x1200_0d004fc6-cc5f-4bde-9666-164791badbe6.jpg?v=1786957215"},{"product_id":"abb-advant-s800-i-o-tu836v1-3bse013237r1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU836V1 3BSE013237R1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU836V1 3BSE013237R1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for physical I\/O termination and field connection in ABB S800 I\/O systems, the \u003cstrong\u003eABB TU836V1 3BSE013237R1\u003c\/strong\u003e (\u003cstrong\u003eTU836V1\u003c\/strong\u003e Extended Module Termination Unit) provides an 8-channel terminal interface with a maximum rated voltage of 250 V and 3 A per I\/O channel.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU836V1 3BSE013237R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE013237R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 12.7 x 7.6 x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C; approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Process Connection\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBoth directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eExtended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Termination and Backplane Interface\u003c\/h3\u003e\n\u003cp\u003eThe TU836V1 provides the physical termination point between field wiring and the associated ABB S800 I\/O module. Its eight channels support up to 250 V and 3 A per I\/O channel according to the supplied specifications.\u003c\/p\u003e\n\u003cp\u003eThe terminal-block connection establishes the field-side electrical interface. Therefore, installers should separate field conductors according to voltage class, signal type, and applicable cabinet wiring requirements.\u003c\/p\u003e\n\u003cp\u003eThe 10 A maximum process connection rating applies to the process connection as specified. Meanwhile, the 2000 V AC dielectric test voltage defines the stated insulation test level rather than a continuous operating voltage.\u003c\/p\u003e\n\u003cp\u003eBecause the supplied data does not specify ModuleBus current consumption or communication velocity, those values should be taken from the applicable S800 I\/O module and system documentation rather than inferred from the TU836V1 rating.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels does the TU836V1 support?\u003cbr\u003eA: The TU836V1 provides 8 I\/O channels.\u003c\/p\u003e\n\u003cp\u003eQ: What are the maximum voltage and current ratings?\u003cbr\u003eA: The maximum rated voltage is 250 V, while the maximum current is 3 A per I\/O channel. The specified maximum process connection current is 10 A.\u003c\/p\u003e\n\u003cp\u003eQ: What dielectric test voltage does the TU836V1 specify?\u003cbr\u003eA: The supplied specification lists a dielectric test voltage of 2000 V AC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TU836V1 on the designated DIN rail or compatible mounting arrangement and verify that the mechanical latch engages correctly.\u003c\/li\u003e\n\u003cli\u003eProvide adequate cabinet clearance around the terminal area so technicians can access field wiring without excessive conductor bending.\u003c\/li\u003e\n\u003cli\u003eRoute power and signal conductors according to the required separation rules for the installation voltage classes.\u003c\/li\u003e\n\u003cli\u003eVerify terminal identification before connecting field conductors. Do not exceed the specified 250 V voltage rating or 3 A per-channel current rating.\u003c\/li\u003e\n\u003cli\u003eKeep protective earth, signal reference, and shield connections consistent with the cabinet grounding design. Avoid creating unintended ground loops through cable shields.\u003c\/li\u003e\n\u003cli\u003eInspect conductor termination for secure mechanical engagement before energizing the associated I\/O circuit.\u003c\/li\u003e\n\u003cli\u003eConfirm operating temperature remains within 0 to +55 deg C. For storage, maintain the specified -40 to +70 deg C range.\u003c\/li\u003e\n\u003cli\u003eBefore dielectric or insulation testing, isolate the module and connected electronics according to the applicable ABB system procedure. Do not apply test voltage to energized electronic circuits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612529291352,"sku":"TU836V1 3BSE013237R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU836V1-3BSE013237R1-3_1200x1200_911c4d72-72bf-46ec-9a2f-eaffd8283bdb.jpg?v=1786957295"},{"product_id":"abb-advant-s800-i-o-tu835v1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU835V1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU835V1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TU835V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTU835V1\u003c\/strong\u003e Extended Module Termination Unit, provides field termination, ModuleBus distribution, and position-address generation for ABB S800 I\/O modules. It supports up to 8 I\/O channels with a maximum rated voltage of 50 V and maximum current of 2 A per channel.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU835V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE013236R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e126 mm W x 110 mm H x 64 mm D, including connector and terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current at Process Connection\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Direction\u003c\/td\u003e\n\u003ctd\u003eBoth directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported I\/O\u003c\/td\u003e\n\u003ctd\u003eAI810, AI815, AI845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e16 I\/O terminals, 4 process power terminals, 4 process power 0 V terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Solid\u003c\/td\u003e\n\u003ctd\u003e0.2 - 4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Stranded\u003c\/td\u003e\n\u003ctd\u003e0.2 - 2.5 mm2, 24 - 12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 - 0.6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 - 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60664-1, EN 50178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I according to IEC 61140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Approval\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50581:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 ModuleBus and Address Distribution\u003c\/h3\u003e\n\u003cp\u003eThe TU835V1 distributes the ModuleBus from the connected I\/O module to the next MTU in the installation. At the same time, it generates the appropriate I\/O module address by shifting outgoing position signals toward the next MTU.\u003c\/p\u003e\n\u003cp\u003eThe MTU supports mechanical configuration through two keys. Each key provides six positions, producing 36 possible mechanical configurations. This keying mechanism physically configures the MTU for compatible I\/O module types without changing the electrical functionality of either the MTU or I\/O module.\u003c\/p\u003e\n\u003cp\u003eThe unit supports AI810, AI815, and AI845 modules according to the supplied technical data. Therefore, the mechanical key positions should match the applicable I\/O module configuration before installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels does the TU835V1 support?\u003c\/p\u003e\n\u003cp\u003eA: The TU835V1 supports up to 8 I\/O channels. Each channel has a maximum rated current of 2 A and a maximum rated voltage of 50 V.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TU835V1 generate the I\/O module address?\u003c\/p\u003e\n\u003cp\u003eA: The MTU generates the appropriate address by shifting the outgoing position signals to the next MTU.\u003c\/p\u003e\n\u003cp\u003eQ: Does the mechanical key configuration change the electrical function of the MTU?\u003c\/p\u003e\n\u003cp\u003eA: No. The two mechanical keys provide physical configuration for different I\/O module types. The selected key positions do not change the electrical functionality of the MTU or I\/O module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU835V1 on a compatible standard DIN rail and verify that the mechanical latch fully locks the unit.\u003c\/li\u003e\n\u003cli\u003eRelease the DIN rail latch with a screwdriver when removing the MTU.\u003c\/li\u003e\n\u003cli\u003eConfirm that the two mechanical keys match the intended I\/O module configuration before installation.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to the terminal assignment and supported process connections.\u003c\/li\u003e\n\u003cli\u003eKeep wiring within the specified solid and stranded conductor ranges.\u003c\/li\u003e\n\u003cli\u003eApply the specified terminal torque of 0.5 - 0.6 Nm during field wiring.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified 7 mm conductor stripping length.\u003c\/li\u003e\n\u003cli\u003eSeparate signal wiring from high-current or high-noise conductors where the installation requires electromagnetic interference control.\u003c\/li\u003e\n\u003cli\u003eRoute shields and protective earth connections according to the plant grounding design and applicable electrical installation standards.\u003c\/li\u003e\n\u003cli\u003eVerify the 50 V maximum rated voltage and 2 A maximum current per I\/O channel before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eConfirm that the ambient temperature remains within 0 to +55 deg C during operation.\u003c\/li\u003e\n\u003cli\u003eInspect the terminal connections and mechanical latch before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612534009944,"sku":"TU835V1 3BSE013236R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU835V1-3BSE013236R1-3_1200x1200_1ba1decb-2d37-45b4-89b1-59e9398ddc0c.jpg?v=1786957391"},{"product_id":"abb-advant-s800-i-o-tu833-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU833 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU833 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TU833 3BSE038726R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTU833\u003c\/strong\u003e Extended Module Termination Unit, provides field termination, process voltage distribution, and ModuleBus signal routing for ABB S800 I\/O modules. It supports up to 16 I\/O channels and two individually isolated process voltage groups.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU833 3BSE038726R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE038726R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e126 mm W x 105 mm H x 64 mm D, including connector and terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C (+32 to +131 deg F); approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C (-40 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Process Connection\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Voltage Groups\u003c\/td\u003e\n\u003ctd\u003e2 individually isolated groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Voltage Fuse\u003c\/td\u003e\n\u003ctd\u003e6.3 A fuse per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eCrimp Snap-in connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connections\u003c\/td\u003e\n\u003ctd\u003e2 terminals per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZP Connections\u003c\/td\u003e\n\u003ctd\u003e1 ZP connection per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Power Connections\u003c\/td\u003e\n\u003ctd\u003e4 x 6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Power 0 V Connections\u003c\/td\u003e\n\u003ctd\u003e10 x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Direction\u003c\/td\u003e\n\u003ctd\u003eBoth directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Lock\u003c\/td\u003e\n\u003ctd\u003eMechanical DIN rail latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle\/Redundant I\/O\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Wire Size\u003c\/td\u003e\n\u003ctd\u003eSolid: 0.2 - 2.5 mm2, 24 - 12 AWG; Stranded: 0.2 - 2.5 mm2, 24 - 12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Wiring\u003c\/td\u003e\n\u003ctd\u003eOne wire per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eDNV-GL, BV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I according to IEC 61140, earth protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEN 50581:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O Modules\u003c\/td\u003e\n\u003ctd\u003eAI810, AI815, AI820, AI830, AI830A, AI835, AI835A, AI843, AI845, AO810, AO810V2, AO815, AO820, AO845, AO845A, DI810, DI811, DI814, DI830, DI831, DI840, DI880, DI885, DO810, DO814, DO815, DO840, DO880, DP820, DP840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 ModuleBus and I\/O Architecture\u003c\/h3\u003e\n\u003cp\u003eThe TU833 distributes the ModuleBus from the installed I\/O module to the next MTU. It also generates the required module address by shifting outgoing position signals toward the next MTU.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the 16-channel configuration provides two I\/O terminals per channel and one ZP connection per channel. This arrangement supports direct field termination while maintaining the physical addressing sequence across the S800 I\/O installation.\u003c\/p\u003e\n\u003cp\u003eThe TU833 also separates process voltage connections into two individually isolated groups. Each group uses a 6.3 A fuse, while the maximum rated current remains 2 A per I\/O channel. Therefore, the application should select fuse ratings according to the actual load requirements and system power design.\u003c\/p\u003e\n\u003cp\u003eThe MTU supports a defined set of ABB S800 I\/O modules, including analog input, analog output, digital input, digital output, and related interface modules. Consequently, engineers should verify the installed I\/O module against the specified compatibility list before commissioning.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels does the ABB TU833 support?\u003c\/p\u003e\n\u003cp\u003eA: The TU833 supports up to 16 I\/O channels. Each channel provides two I\/O connections and one ZP connection.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TU833 handle process voltage distribution?\u003c\/p\u003e\n\u003cp\u003eA: The TU833 provides two individually isolated process voltage groups. Each group has a 6.3 A fuse, while the maximum rated voltage is 50 V.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TU833 generate the I\/O module address?\u003c\/p\u003e\n\u003cp\u003eA: The MTU shifts the outgoing position signals to the next MTU. This process generates the correct address for the connected S800 I\/O module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU833 on a standard DIN rail and engage the mechanical latch before wiring.\u003c\/li\u003e\n\u003cli\u003eConfirm that the mounting direction and available cabinet clearance match the installation arrangement.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to the assigned channel and terminal configuration.\u003c\/li\u003e\n\u003cli\u003eUse solid or stranded conductors within the specified 0.2 - 2.5 mm2 wire range.\u003c\/li\u003e\n\u003cli\u003eUse only one wire per terminal and maintain the specified 6 mm stripping length.\u003c\/li\u003e\n\u003cli\u003eVerify the process voltage group assignment before connecting field power.\u003c\/li\u003e\n\u003cli\u003eCheck the fuse arrangement for each isolated process voltage group against the application load.\u003c\/li\u003e\n\u003cli\u003eRoute process wiring separately from high-noise power conductors where the cabinet design permits.\u003c\/li\u003e\n\u003cli\u003eVerify protective earth and cabinet grounding according to the applicable installation standard.\u003c\/li\u003e\n\u003cli\u003eConfirm the connected I\/O module appears in the specified compatible module list.\u003c\/li\u003e\n\u003cli\u003eCheck ModuleBus continuity and the physical MTU sequence before commissioning.\u003c\/li\u003e\n\u003cli\u003eInspect all crimp snap-in connections for secure mechanical engagement before energizing the system.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 50 V maximum rated voltage or 2 A maximum current per I\/O channel.\u003c\/li\u003e\n\u003cli\u003eVerify operating ambient temperature remains within the specified range during normal operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612537483352,"sku":"TU833 3BSE038726R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU833-3BSE038726R1-3_1200x1200_16e30dad-dcc6-48aa-9375-94582742639e.jpg?v=1786957496"},{"product_id":"abb-advant-s800-i-o-tu830v1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU830V1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU830V1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for field wiring termination, process voltage distribution, and ModuleBus signal routing in the ABB S800 I\/O system, the \u003cstrong\u003eABB TU830V1\u003c\/strong\u003e (\u003cstrong\u003eTU830\u003c\/strong\u003e Extended Module Termination Unit) provides the physical interface between field circuits and the I\/O module.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU830V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTU830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit (MTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ Catalog Code\u003c\/td\u003e\n\u003ctd\u003e3BSE013234R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Channels\u003c\/td\u003e\n\u003ctd\u003eUp to 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Current per Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Voltage Connections\u003c\/td\u003e\n\u003ctd\u003e2 individually isolated groups, UP1 and UP2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e6.3 A time-lag fuse, 5 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Function\u003c\/td\u003e\n\u003ctd\u003eDistributes ModuleBus and shifts position signals for I\/O module addressing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Solid\u003c\/td\u003e\n\u003ctd\u003e0.2 - 4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Stranded\u003c\/td\u003e\n\u003ctd\u003e0.2 - 2.5 mm2, 24 - 12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Tightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 - 0.6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Keying\u003c\/td\u003e\n\u003ctd\u003e36 coding combinations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eBuilt-in system grounding mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModuleBus and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe TU830V1 distributes ModuleBus communication through the S800 I\/O termination structure. It also shifts outgoing position signals so that the connected I\/O module receives the corresponding hardware position address.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the MTU supports up to 16 I\/O channels while maintaining separate process voltage groups. The two groups provide individual isolation and fuse protection for connected field circuits.\u003c\/p\u003e\n\u003cp\u003eThe 36 available mechanical coding combinations restrict incompatible I\/O module insertion. Therefore, the selected coding must correspond to the intended I\/O module before installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TU830V1 provide I\/O signal conversion?\u003c\/p\u003e\n\u003cp\u003eA: No. The TU830V1 functions as a termination and distribution unit. The connected S800 I\/O module performs the actual signal processing.\u003c\/p\u003e\n\u003cp\u003eQ: What process voltage protection does the TU830V1 provide?\u003c\/p\u003e\n\u003cp\u003eA: The unit provides two individually isolated process voltage groups. Each group uses a 6.3 A time-lag fuse according to the supplied specifications.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TU830V1 support more than 8 I\/O channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied data specifies a maximum of 16 I\/O channels for the TU830V1.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU830V1 securely on the specified DIN rail before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eVerify the mechanical coding before inserting the associated S800 I\/O module.\u003c\/li\u003e\n\u003cli\u003eSeparate process voltage wiring from communication and low-level signal wiring where cabinet design permits.\u003c\/li\u003e\n\u003cli\u003eMaintain correct polarity and terminal identification for every field circuit.\u003c\/li\u003e\n\u003cli\u003eTighten field terminals to 0.5 - 0.6 Nm where the supplied specification applies.\u003c\/li\u003e\n\u003cli\u003eSelect conductor sizes within the stated 0.2 - 4 mm2 solid or 0.2 - 2.5 mm2 stranded range.\u003c\/li\u003e\n\u003cli\u003eConnect the grounding arrangement according to the S800 installation design and cabinet grounding scheme.\u003c\/li\u003e\n\u003cli\u003eVerify both process voltage groups independently before energizing the connected I\/O circuits.\u003c\/li\u003e\n\u003cli\u003eInspect fuse installation and confirm that the installed fuse type matches the specified protection arrangement.\u003c\/li\u003e\n\u003cli\u003eDo not exceed 50 V rated voltage or 2 A rated current per I\/O channel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612551278680,"sku":"TU832","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU832-2_1200x1200_790043fa-3d64-431c-a1b6-58ed1139b0c1.jpg?v=1786957670"},{"product_id":"abb-advant-s800-i-o-tu831v1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU831V1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU831V1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for field termination and ModuleBus distribution in the ABB S800 I\/O system, the \u003cstrong\u003eABB TU831V1 3BSE013235R1\u003c\/strong\u003e (\u003cstrong\u003eTU831V1\u003c\/strong\u003e Extended Module Termination Unit) provides physical connections for compatible digital I\/O modules. It supports up to 8 I\/O channels, with a maximum rated voltage of 250 V and maximum current of 3 A per channel.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU831V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE013235R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg (0.48 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e126 mm W x 64 mm D x 110 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstalled Width\u003c\/td\u003e\n\u003ctd\u003e120.5 mm edge to edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eUp to 8 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e16 terminals, 2 terminals per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O Modules\u003c\/td\u003e\n\u003ctd\u003eDI820, DI821, DO820, DO821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Direction\u003c\/td\u003e\n\u003ctd\u003eBoth directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Distribution\u003c\/td\u003e\n\u003ctd\u003eTo the I\/O module and next MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Generation\u003c\/td\u003e\n\u003ctd\u003ePosition signal shifting to the next MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Solid\u003c\/td\u003e\n\u003ctd\u003e0.2 - 6 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Stranded\u003c\/td\u003e\n\u003ctd\u003e0.2 - 4 mm2, 24 - 10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 - 0.6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C (+32 to +131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproved Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C (-40 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Categories\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60664-1, EN 50178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I according to IEC 61140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certifications\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEN 50581:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O ModuleBus and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe TU831V1 distributes the ModuleBus from the mounted I\/O module toward the next MTU. It also shifts outgoing position signals so the following MTU receives the corresponding module address position.\u003c\/p\u003e\n\u003cp\u003eThe eight-channel configuration provides a compact termination arrangement for compatible S800 I\/O modules. Each channel uses two process terminals, giving 16 process connections for the complete eight-channel arrangement.\u003c\/p\u003e\n\u003cp\u003eThe MTU does not function as an independent I\/O processing module. Instead, it provides the mechanical, electrical, termination, and ModuleBus interface required by the supported I\/O modules. Therefore, module compatibility must be checked before installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O channels does the ABB TU831V1 support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The TU831V1 supports up to 8 I\/O channels and provides 16 process connections, with two terminals assigned to each channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What I\/O modules are specified for use with the TU831V1?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data identifies DI820, DI821, DO820, and DO821 as compatible I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum electrical rating per I\/O channel?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Each I\/O channel has a maximum rated voltage of 250 V and a maximum current rating of 3 A.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU831V1 on a suitable standard DIN rail and engage the mechanical latch fully.\u003c\/li\u003e\n\u003cli\u003eVerify the MTU orientation and terminal accessibility before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eConfirm that the selected I\/O module is one of the specified compatible types.\u003c\/li\u003e\n\u003cli\u003eKeep field wiring separated from high-energy switching conductors where the installation requires signal-noise control.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring to minimize unnecessary parallel runs with power conductors.\u003c\/li\u003e\n\u003cli\u003eUse conductor sizes within the specified 0.2 - 6 mm2 solid or 0.2 - 4 mm2 stranded range.\u003c\/li\u003e\n\u003cli\u003eApply the specified 0.5 - 0.6 Nm terminal torque during wiring.\u003c\/li\u003e\n\u003cli\u003eStrip approximately 7 mm of insulation from conductors before termination.\u003c\/li\u003e\n\u003cli\u003eVerify protective earth arrangements according to the applicable installation standard because the equipment is Class I.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections before energization and verify that no conductor strands contact adjacent terminals.\u003c\/li\u003e\n\u003cli\u003eConfirm the ModuleBus path and MTU position before commissioning the connected I\/O module.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified 250 V maximum voltage or 3 A maximum current per I\/O channel.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified environmental limits during installation and operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612554457176,"sku":"TU831V1 3BSE013235R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU831V1-3BSE013235R1-3_1200x1200_0e7341d7-9211-4bd2-91b8-f41d1775a978.jpg?v=1786957765"},{"product_id":"abb-advant-s800-i-o-tu831v1-3bse013235r1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU831V1 3BSE013235R1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU831V1 3BSE013235R1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for field I\/O termination and ModuleBus distribution in the ABB S800 I\/O system, the \u003cstrong\u003eABB TU831V1 3BSE013235R1\u003c\/strong\u003e (\u003cstrong\u003eTU831V1\u003c\/strong\u003e Extended Module Termination Unit) provides physical connections for up to 8 I\/O channels. The unit distributes ModuleBus signals to the I\/O module and the next MTU while generating the required module address position signals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU831V1 3BSE013235R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE013235R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 12.7 x 11.6 x 6.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e16 connections for up to 8 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail; mounting in both directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C; approvals issued for +5 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O ModuleBus and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe TU831V1 distributes the ModuleBus connection between the installed I\/O module and the adjacent MTU. It also shifts outgoing position signals to generate the correct address for the next I\/O position.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the MTU provides 16 process connections for 8 I\/O channels. Each channel supports a maximum rated current of 3 A and a maximum rated voltage of 250 V.\u003c\/p\u003e\n\u003cp\u003eThe single I\/O configuration does not provide redundant I\/O termination. Therefore, system designers should match the MTU configuration with the selected S800 I\/O module and field wiring arrangement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels can the TU831V1 support?\u003cbr\u003eA: The TU831V1 supports up to 8 I\/O channels with 16 process connections.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical rating applies to each I\/O channel?\u003cbr\u003eA: Each I\/O channel has a maximum rated voltage of 250 V and a maximum current of 3 A.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TU831V1 provide redundant I\/O termination?\u003cbr\u003eA: No. The supplied specifications identify the TU831V1 as a single I\/O termination unit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU831V1 on a compatible DIN rail and secure the mechanical latch before wiring.\u003c\/li\u003e\n\u003cli\u003eInstall the MTU in the specified mounting orientation and maintain adequate clearance for terminal access.\u003c\/li\u003e\n\u003cli\u003eVerify the installed I\/O module compatibility with the TU831V1 before applying field power.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring separately from high-current switching conductors where practical to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate terminal wiring practices and verify conductor sizes against the connected field circuit requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm polarity and circuit voltage before connecting field devices to the terminal block.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections for secure mechanical engagement before energizing the I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified operating temperature range of 0 to +55 deg C and relative humidity range of 5 to 95 %, non-condensing.\u003c\/li\u003e\n\u003cli\u003eObserve the 250 V maximum rated voltage and 3 A maximum current per I\/O channel during system design.\u003c\/li\u003e\n\u003cli\u003eVerify dielectric isolation requirements before performing commissioning or insulation testing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612555997272,"sku":"TU831 3BSE008530R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU831-3BSE008530R1-3_1200x1200_889c5b01-dfea-455c-b4a6-c45c0a9dc396.jpg?v=1786957860"},{"product_id":"abb-advant-s800-i-o-tb810-modulebus-optical-port","title":"ABB Advant S800 I\/O TB810 ModuleBus Optical Port","description":"\u003ch2\u003eABB TB810 ModuleBus Optical Port\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TB810 3BSE008560R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTB810\u003c\/strong\u003e ModuleBus Optical Port, provides fiber optic communication between S800 I\/O ModuleBus segments. It operates at 10 Mbit\/s and supports single-mode fiber transmission over distances up to 2 km.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTB810 3BSE008560R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE008560R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModuleBus Optical Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2 x 5.2 x 4.2 cm shipping size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbit\/s (10 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 2 km (1.24 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eFiber optic ModuleBus interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eSingle-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Origin\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O ModuleBus Communication\u003c\/h3\u003e\n\u003cp\u003eThe TB810 converts the ModuleBus communication path to an optical fiber interface. Therefore, the unit supports optical transmission between compatible ABB S800 I\/O ModuleBus sections where electrical bus cabling is not suitable.\u003c\/p\u003e\n\u003cp\u003eThe specified communication rate is 10 Mbit\/s. In addition, the supplied data specifies a maximum transmission distance of up to 2 km when using single-mode fiber.\u003c\/p\u003e\n\u003cp\u003eBecause the interface uses optical transmission, the fiber path should remain physically separated from electrical power wiring and high-noise conductors. Installers should also maintain the specified fiber bend radius and protect optical connectors from contamination during installation.\u003c\/p\u003e\n\u003cp\u003eThe 24 VDC operating supply must be connected with correct polarity and appropriate industrial wiring practices. The TB810 should be installed only with compatible ABB S800 I\/O equipment and ModuleBus configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication medium does the TB810 use?\u003cbr\u003eA: The TB810 uses a fiber optic ModuleBus interface and the supplied specification identifies single-mode fiber as the supported fiber type.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified communication speed?\u003cbr\u003eA: The specified ModuleBus optical communication rate is 10 Mbit\/s (10 Mbps).\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified maximum transmission distance?\u003cbr\u003eA: The supplied specification states a transmission distance of up to 2 km (1.24 miles). Actual installation performance depends on the selected fiber and optical link conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the TB810 model and 3BSE008560R1 spare number before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the available supply is 24 VDC and matches the system wiring requirements.\u003c\/li\u003e\n\u003cli\u003eInstall the unit within the compatible ABB S800 I\/O ModuleBus architecture.\u003c\/li\u003e\n\u003cli\u003eRoute optical fiber separately from power and high-current conductors.\u003c\/li\u003e\n\u003cli\u003eKeep fiber connectors clean and capped until connection.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive bending, pulling, or mechanical loading of the optical cable.\u003c\/li\u003e\n\u003cli\u003eCheck the fiber type before connection; the supplied specification identifies single-mode fiber.\u003c\/li\u003e\n\u003cli\u003eInspect the optical path and connectors if communication faults occur.\u003c\/li\u003e\n\u003cli\u003eConfirm ModuleBus communication after installation before placing the associated I\/O segment into service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612574412888,"sku":"TB810 3BSE008560R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TB810-3BSE008560R1-3_1200x1200_3bf86f0d-b765-4e1b-b0b3-a79c92f27bdc.jpg?v=1786958132"},{"product_id":"abb-tk854v030-communication-interface-module","title":"ABB TK854V030 Communication Interface Module","description":"\u003ch2\u003eABB TK854V030 Communication Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for physical interface and system-level communication within an ABB industrial control architecture, the \u003cstrong\u003eABB TK854V030\u003c\/strong\u003e (\u003cstrong\u003eTK854V030\u003c\/strong\u003e Communication Interface Module) provides hardware-level connectivity between the associated system components. The supplied data does not identify a specific protocol, electrical interface, or backplane specification.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK854V030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication \/ Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eABB industrial automation and control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent; supplied data references Advant OCS, Freelance, and System 800xA environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Interface\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail or rack mounting, depending on associated housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eTypically IP20, according to supplied information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Status\u003c\/td\u003e\n\u003ctd\u003eCompliant with applicable environmental directives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Control Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TK854V030 functions as a hardware interface component, so the associated system determines its actual communication path and electrical assignment. Therefore, installers should verify the compatible rack, terminal arrangement, and system documentation before energizing the module.\u003c\/p\u003e\n\u003cp\u003eABB control architectures may use dedicated backplane or system-bus communication between controllers, interface modules, and I\/O assemblies. However, the supplied TK854V030 information does not define a specific bus speed, protocol, connector pinout, or firmware compatibility range. Consequently, these parameters should not be assumed from the model number alone.\u003c\/p\u003e\n\u003cp\u003eFor system integration, confirm the hardware revision and the target ABB platform. Then verify the mating connector, rack position, power source, and communication interface against the applicable ABB hardware documentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the supplied specification confirm a specific communication protocol for TK854V030?\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied information identifies the unit as a communication\/interface module but does not specify a protocol or network standard.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TK854V030 be installed directly on a DIN rail?\u003c\/p\u003e\n\u003cp\u003eA: The supplied information lists DIN-rail or rack mounting, depending on the associated housing or sub-rack design. The applicable mounting arrangement must therefore be confirmed from the system hardware documentation.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified power consumption of TK854V030?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data does not provide a power-consumption value. The system-specific hardware manual should be used to determine the required supply and backplane load.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the exact TK854V030 hardware revision before installation.\u003c\/li\u003e\n\u003cli\u003eVerify the compatible ABB rack, mounting carrier, or DIN-rail assembly.\u003c\/li\u003e\n\u003cli\u003eIsolate system power before connecting or removing the module.\u003c\/li\u003e\n\u003cli\u003eInspect connectors for contamination, mechanical damage, or bent contacts.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring separately from high-voltage and high-current conductors where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate cable shielding and connect shields according to the ABB system grounding scheme.\u003c\/li\u003e\n\u003cli\u003eAvoid unnecessary cable loops and excessive mechanical stress at connectors.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal assignments and connector orientation from the applicable ABB installation manual.\u003c\/li\u003e\n\u003cli\u003eCheck the enclosure protection level when the module operates outside a controlled cabinet environment.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify module seating, power status, communication status, and system diagnostics before placing the control system into service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612578443352,"sku":"TK854V030","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK854V030_1200x1200_dfb5d67d-869f-4b21-b014-879a3c46fa32.jpg?v=1786958222"},{"product_id":"abb-tk853v020-modem-cable","title":"ABB TK853V020 Modem Cable","description":"\u003ch2\u003eABB TK853V020 Modem Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for serial modem communication between TC562 and TP830, the \u003cstrong\u003eABB 3BSC950201R1\u003c\/strong\u003e (\u003cstrong\u003eTK853V020\u003c\/strong\u003e Modem Cable) provides a prefabricated 2 m physical connection for the TP830 serial interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BSC950201R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eTK853V020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eModem cable for serial interfaces on TP830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTC562 modem to TP830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length\u003c\/td\u003e\n\u003ctd\u003e2000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e854442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Serial Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TK853V020 provides a fixed physical connection between the TC562 modem and the TP830 serial interface. Therefore, installation should preserve the cable routing and connector orientation specified for the associated ABB hardware.\u003c\/p\u003e\n\u003cp\u003eBecause the supplied documentation identifies this item as a prefabricated cable, the cable itself does not provide programmable communication functions, protocol conversion, or independent power processing. Instead, it carries the serial interface connection between the designated devices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What equipment does the TK853V020 connect?\u003c\/strong\u003e\u003cbr\u003eA: The cable connects the TC562 modem to the serial interface on the TP830.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the specified cable length?\u003c\/strong\u003e\u003cbr\u003eA: The cable length is 2 m, with a listed product length of 2000 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the cable have a specified power consumption?\u003c\/strong\u003e\u003cbr\u003eA: No. The supplied data identifies it as a prefabricated modem cable, so no independent power consumption is specified.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the cable identification before installation and confirm the required TC562 and TP830 connection points.\u003c\/li\u003e\n\u003cli\u003eRoute the cable without excessive mechanical tension, sharp bends, or compression.\u003c\/li\u003e\n\u003cli\u003eKeep the serial cable separated from high-current power conductors where practical to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eEnsure connectors are fully seated before commissioning the serial communication path.\u003c\/li\u003e\n\u003cli\u003eDo not modify the prefabricated cable or alter its connector termination.\u003c\/li\u003e\n\u003cli\u003eInspect the cable jacket and connectors for mechanical damage before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm serial communication after connection using the applicable TP830 and TC562 commissioning procedure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612585422936,"sku":"TK853V020 3BSC950201R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK853V020-3BSC950201R1-2_1200x1200_69279f9d-9b6f-49f1-9d1b-058baf375d3e.jpg?v=1786958315"},{"product_id":"abb-tk852v010-shielded-ftp-cat-5e-cross-over-cable","title":"ABB TK852V010 Shielded FTP CAT 5e Cross-Over Cable","description":"\u003ch2\u003eABB TK852V010 Shielded FTP CAT 5e Cross-Over Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for shielded Ethernet cross-over communication in ABB Advant Master process control systems, the \u003cstrong\u003eABB TK852V010\u003c\/strong\u003e (\u003cstrong\u003eTK852V010\u003c\/strong\u003e Shielded FTP CAT 5e Cross-Over Cable) provides a prefabricated cable assembly for direct network interconnection. The product ID is \u003cstrong\u003e3BSC950342R1\u003c\/strong\u003e. Its specified construction is shielded FTP CAT 5e, with a product net length of 970 mm.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK852V010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSC950342R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded FTP CAT 5e Cross-Over\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Function\u003c\/td\u003e\n\u003ctd\u003eEthernet cross-over interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e970 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e970 mm length; height and width not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eFTP, shielded construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eFitted cable assembly; specific connector type not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e854442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85444290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Status\u003c\/td\u003e\n\u003ctd\u003eProduct not in WEEE scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Ethernet Cable Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TK852V010 uses shielded FTP CAT 5e construction for Ethernet signal transmission. Therefore, the cable should maintain appropriate shielding continuity through the installed communication path.\u003c\/p\u003e\n\u003cp\u003eThe cross-over configuration changes the conductor pairing arrangement between cable ends. Consequently, installers should verify the required interface wiring before replacing a straight-through Ethernet cable.\u003c\/p\u003e\n\u003cp\u003eThe supplied data identifies the assembly as a prefabricated cable rather than an active network device. It therefore has no specified power consumption, firmware, or configurable communication parameters.\u003c\/p\u003e\n\u003cp\u003eFor ABB Advant Master installations, maintain the cable routing and shielding practices specified by the applicable system documentation. Avoid unnecessary parallel routing with high-energy power conductors, and maintain physical separation where the installation environment requires it.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is TK852V010 an active Ethernet communication module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. TK852V010 is a passive prefabricated Shielded FTP CAT 5e cross-over cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the specified cable length?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The product net depth \/ length is specified as 970 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied data specify an operating temperature range?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The provided ABB data does not specify an operating temperature range for TK852V010.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the required network connection uses a cross-over configuration before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm connector compatibility with the connected ABB communication interfaces.\u003c\/li\u003e\n\u003cli\u003eMaintain shield continuity according to the applicable ABB installation documentation.\u003c\/li\u003e\n\u003cli\u003eRoute the cable away from high-voltage and high-current conductors where practical.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive mechanical tension, sharp bends, or crushing of the cable jacket.\u003c\/li\u003e\n\u003cli\u003eInspect both cable ends for connector damage before commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet communication after installation using the applicable system diagnostics.\u003c\/li\u003e\n\u003cli\u003eRecord the installed cable identification as TK852V010 \/ 3BSC950342R1 for maintenance documentation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612589158488,"sku":"TK852V010","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK852V010-3_1200x1200_9e0a3991-1f61-4df2-9661-16cefb9a5a4f.jpg?v=1786958397"},{"product_id":"abb-s800-i-o-tk851v010-connection-cable","title":"ABB S800 I\/O TK851V010 Connection Cable","description":"\u003ch2\u003eABB TK851V010 Connection Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for RCU link and BC810 interconnection functions, the \u003cstrong\u003eABB TK851V010\u003c\/strong\u003e (\u003cstrong\u003eTK851V010\u003c\/strong\u003e Connection Cable) provides a prefabricated 1 m physical connection between compatible ABB system components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK851V010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSC950262R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRCU Link Cable; BC810 Interconnection Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1000 mm x 10 mm x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e854442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCIP\u003c\/td\u003e\n\u003ctd\u003eNo SVHC present Switzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Interconnection Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TK851V010 provides a dedicated cable path for RCU link and BC810 interconnection functions. Therefore, installation should preserve the specified cable routing and connector orientation for the connected ABB hardware.\u003c\/p\u003e\n\u003cp\u003eBecause the supplied documentation does not state conductor assignment, shielding construction, connector pinout, or electrical ratings, these parameters should be verified against the applicable ABB system documentation before installation.\u003c\/p\u003e\n\u003cp\u003eFor industrial control cabinets, route the cable separately from high-energy power conductors where practical. Also, avoid excessive bending, tensile loading, crushing, or mechanical stress at the connector ends.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What equipment functions does the TK851V010 support?\u003cbr\u003eA: ABB specifies the cable for RCU Link Cable and BC810 Interconnection Cable applications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the physical cable length?\u003cbr\u003eA: The specified cable length is 1 m, with a product net length of 1000 mm.\u003c\/p\u003e\n\u003cp\u003eQ: Is power consumption applicable to the TK851V010?\u003cbr\u003eA: No. The product is a passive prefabricated connection cable, so power consumption is not specified as an operating parameter.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the installed cable is \u003cstrong\u003eABB TK851V010\u003c\/strong\u003e, Product ID 3BSC950262R1, before connection.\u003c\/li\u003e\n\u003cli\u003eVerify the mating interfaces and connector configuration against the applicable ABB hardware documentation.\u003c\/li\u003e\n\u003cli\u003eInstall the cable without excessive bending, pulling, twisting, or compression.\u003c\/li\u003e\n\u003cli\u003eKeep the cable routing clear of mechanical interference from cabinet doors, mounting rails, and adjacent hardware.\u003c\/li\u003e\n\u003cli\u003eSeparate the cable from high-current or high-voltage wiring where the cabinet layout permits.\u003c\/li\u003e\n\u003cli\u003eDo not modify the cable, connector, shielding, or conductor arrangement unless ABB documentation specifically permits the modification.\u003c\/li\u003e\n\u003cli\u003eInspect connector seating before system commissioning and verify that no connector is mechanically stressed by cable routing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612592894040,"sku":"TK851V010 3BSC950262R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK851V010-3BSC950262R1-3_1200x1200_f45813be-a62c-4bf9-8fb5-44c4a83af65a.jpg?v=1786958500"},{"product_id":"abb-advant-ocs-and-advant-800xa-tk850v007-3bsc950192r1-cex-bus-extension-cable","title":"ABB Advant OCS and Advant-800xA TK850V007 3BSC950192R1 CEX-Bus Extension Cable","description":"\u003ch2\u003eABB TK850V007 3BSC950192R1 CEX-Bus Extension Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for CEX-Bus signal extension, the \u003cstrong\u003eABB TK850V007 3BSC950192R1\u003c\/strong\u003e (\u003cstrong\u003eTK850V007\u003c\/strong\u003e CEX-Bus Extension Cable) provides a direct cable connection for CEX-Bus network expansion. The assembly has a specified length of 0.7 m and supports low-voltage CEX-Bus communication within ABB control hardware.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK850V007 3BSC950192R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCEX-Bus Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSC950192R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBend Radius\u003c\/td\u003e\n\u003ctd\u003eMinimum 5 x cable diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCEX-Bus Communication and Cable Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TK850V007 provides the physical cable path for CEX-Bus extension between compatible ABB control system components. Therefore, installation should preserve the specified electrical connection and mechanical routing conditions.\u003c\/p\u003e\n\u003cp\u003eThe cable operates below 24 VDC and has a typical current rating below 50 mA. In addition, the specified operating temperature range extends from -25 deg C to +70 deg C.\u003c\/p\u003e\n\u003cp\u003eThe 0.7 m cable length supports short-distance CEX-Bus extension. Furthermore, installers should maintain a minimum bend radius of 5 x the cable diameter to prevent excessive mechanical stress on the cable assembly.\u003c\/p\u003e\n\u003cp\u003eThis component should be applied only where the connected ABB hardware specifies TK850-series CEX-Bus cable compatibility. The supplied data does not define a separate firmware requirement, communication speed, shielding termination, or connector pinout.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the rated cable length of the ABB TK850V007?\u003c\/p\u003e\n\u003cp\u003eA: The specified cable length is 0.7 m.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical limits are specified for the TK850V007?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications state a voltage rating below 24 VDC and a typical current rating below 50 mA.\u003c\/p\u003e\n\u003cp\u003eQ: What bend radius should be maintained during installation?\u003c\/p\u003e\n\u003cp\u003eA: Maintain a minimum bend radius of 5 x the cable diameter.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the TK850V007 part number and 3BSC950192R1 spare model against the equipment documentation before installation.\u003c\/li\u003e\n\u003cli\u003eConnect the cable only to compatible CEX-Bus interfaces specified by the ABB system documentation.\u003c\/li\u003e\n\u003cli\u003eRoute the cable without sharp bends, crushing, twisting, or excessive tensile loading.\u003c\/li\u003e\n\u003cli\u003eMaintain the minimum bend radius of 5 x the cable diameter throughout the cable route.\u003c\/li\u003e\n\u003cli\u003eKeep the cable away from mechanical movement and sources of electrical interference where practical.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified voltage and current limits.\u003c\/li\u003e\n\u003cli\u003eInspect the connectors and cable jacket before energizing the connected equipment.\u003c\/li\u003e\n\u003cli\u003eDo not modify the cable assembly, connector termination, or conductor arrangement unless ABB documentation explicitly permits the modification.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612596039768,"sku":"TK851 3BSC950192R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK851-3BSC950192R1-3_1200x1200_0a899df7-71af-4e9a-bf13-9b32f8f36ff3.jpg?v=1786958600"},{"product_id":"abb-tk850v007-3bsc950192r1-cex-bus-extension-cable","title":"ABB TK850V007 3BSC950192R1 CEX-Bus Extension Cable","description":"\u003ch2\u003eABB TK850V007 3BSC950192R1 CEX-Bus Extension Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TK850V007 3BSC950192R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTK850V007\u003c\/strong\u003e CEX-Bus Extension Cable, provides a 0.7 m physical connection for CEX-Bus extension within ABB control hardware. The cable uses prefabricated construction and requires a TK851 CEX-Bus terminator when installed.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK850V007 3BSC950192R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCEX-Bus Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEX-Bus Requirement\u003c\/td\u003e\n\u003ctd\u003eTK851 CEX-Bus terminator required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd\u003e700 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e13 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e854442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB CEX-Bus Extension Characteristics\u003c\/h3\u003e\n\u003cp\u003eTK850V007 provides the physical cable path required for CEX-Bus extension between compatible ABB control-system components. The supplied cable length is 0.7 m, while the documented physical dimensions are 700 mm x 13 mm x 6 mm.\u003c\/p\u003e\n\u003cp\u003eThe cable is supplied as a prefabricated assembly. Therefore, field fabrication of the cable connection is not part of the specified product configuration. Furthermore, ABB specifies the use of a TK851 CEX-Bus terminator with TK850V007.\u003c\/p\u003e\n\u003cp\u003eThe cable itself is a passive interconnection component. Consequently, it has no separately specified power-consumption rating.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the specified cable length of TK850V007 3BSC950192R1?\u003cbr\u003eA: The specified cable length is 0.7 m, corresponding to a product net length of 700 mm.\u003c\/p\u003e\n\u003cp\u003eQ: Is a terminator required when using TK850V007?\u003cbr\u003eA: Yes. The supplied ABB data specifies that TK850V007 requires a TK851 CEX-Bus terminator.\u003c\/p\u003e\n\u003cp\u003eQ: Does TK850V007 consume electrical power?\u003cbr\u003eA: No. TK850V007 is a passive prefabricated cable and has no separately specified power-consumption requirement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the cable part number before installation: TK850V007, 3BSC950192R1.\u003c\/li\u003e\n\u003cli\u003eConfirm that the connected equipment supports the ABB CEX-Bus interface.\u003c\/li\u003e\n\u003cli\u003eInstall the TK851 CEX-Bus terminator as specified for the TK850V007 configuration.\u003c\/li\u003e\n\u003cli\u003eRoute the cable without excessive bending, crushing, or mechanical tension.\u003c\/li\u003e\n\u003cli\u003eKeep the cable separated from sources of strong electromagnetic interference where practical.\u003c\/li\u003e\n\u003cli\u003eDo not modify the prefabricated cable assembly unless the applicable ABB installation documentation explicitly permits modification.\u003c\/li\u003e\n\u003cli\u003eVerify connector seating before energizing the associated control hardware.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified cable routing and mechanical clearance required by the installed ABB equipment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612601675864,"sku":"TK850V007 3BSC950192R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK850V007-3BSC950192R1-3_1200x1200_aedf13db-f8ba-4835-a737-90b743fc9934.jpg?v=1786958821"},{"product_id":"abb-tk821v020-battery-cable","title":"ABB TK821V020 Battery Cable","description":"\u003ch2\u003eABB TK821V020 Battery Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for battery power connection within ABB prefabricated cable assemblies, the \u003cstrong\u003eABB TK821V020\u003c\/strong\u003e (\u003cstrong\u003eTK821V020 Battery Cable\u003c\/strong\u003e) provides a direct physical connection between the battery circuit and the associated ABB control hardware. The cable has a specified length of 2.0 m and is supplied as a prefabricated cable.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK821V020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSC950202R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eBattery Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCable length: 2.0 m; other dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable; no power consumption specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNSPSC\u003c\/td\u003e\n\u003ctd\u003e39120000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Order Quantity\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Multiple\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMade To Order\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelling Unit\u003c\/td\u003e\n\u003ctd\u003epiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Control and Cable Integration\u003c\/h3\u003e\n\u003cp\u003eThe TK821V020 is a passive battery cable, so it does not perform signal processing, protocol conversion, or active control functions. Instead, it provides the physical electrical path required by the associated ABB hardware.\u003c\/p\u003e\n\u003cp\u003eBecause the supplied documentation does not specify conductor size, connector type, pin assignment, insulation rating, or maximum current, these values should be verified against the applicable ABB system documentation before installation.\u003c\/p\u003e\n\u003cp\u003eThe cable length is specified as 2.0 m. Therefore, installation should maintain the cable route without introducing unnecessary mechanical tension, excessive bending, or interference with adjacent power and signal wiring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the specified cable length of the ABB TK821V020?\u003c\/p\u003e\n\u003cp\u003eA: The specified cable length is 2.0 m.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK821V020 consume electrical power?\u003c\/p\u003e\n\u003cp\u003eA: No active power consumption is specified because the TK821V020 is a passive prefabricated battery cable.\u003c\/p\u003e\n\u003cp\u003eQ: Are the conductor size and connector pinout specified in the supplied data?\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied ABB data identifies the product as a Battery Cable but does not specify conductor size or connector pin assignment. Refer to the applicable system wiring documentation before termination or replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the complete part number \u003cstrong\u003e3BSC950202R1 \/ TK821V020\u003c\/strong\u003e before installation.\u003c\/li\u003e\n\u003cli\u003eVerify the cable destination against the applicable ABB system wiring diagram.\u003c\/li\u003e\n\u003cli\u003eConfirm connector orientation and mating compatibility before applying electrical power.\u003c\/li\u003e\n\u003cli\u003eRoute the cable away from sources of mechanical abrasion and avoid sharp bends.\u003c\/li\u003e\n\u003cli\u003eDo not apply tensile load to the cable or connector during installation.\u003c\/li\u003e\n\u003cli\u003eKeep battery wiring separated from high-current switching conductors where the system installation rules require separation.\u003c\/li\u003e\n\u003cli\u003eInspect connectors and cable insulation for mechanical damage before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eVerify polarity and electrical continuity according to the applicable ABB wiring documentation.\u003c\/li\u003e\n\u003cli\u003eDo not substitute a cable with different conductor, connector, or length specifications unless ABB documentation permits the substitution.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612605345880,"sku":"TK850","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK850-2_1200x1200_26210c55-c5d7-44c7-9705-39ba0f0ec855.jpg?v=1786958916"},{"product_id":"abb-bdm000150r1-tk-821f-serial-cable","title":"ABB BDM000150R1 TK 821F Serial Cable","description":"\u003ch2\u003eABB BDM000150R1 TK 821F Serial Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB BDM000150R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTK 821F\u003c\/strong\u003e Serial Cable, provides a two-channel serial connection between the FI 820F interface and TB 870F terminal block. The cable incorporates integral connectors and has a specified length of 0.5 m.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBDM000150R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BDM000150R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eTK 821F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eSerial Cable, 2 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eIntegral connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFI 820F to TB 870F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Block\u003c\/td\u003e\n\u003ctd\u003eTB 870F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquivalent Part\u003c\/td\u003e\n\u003ctd\u003eDFA 021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Classification\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified; ABB database lists 0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eLength: 0.5 m; other dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e854442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSerial Interface and Cable Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TK 821F uses a prefabricated two-channel cable assembly with integral connectors. It connects the FI 820F interface directly to the TB 870F terminal block. Therefore, the cable provides the physical serial interconnection without requiring field termination of individual conductors.\u003c\/p\u003e\n\u003cp\u003eThe specified cable length is 0.5 m. ABB also identifies the DFA 021 as an identical cable designation. Because the supplied documentation does not define conductor allocation, pin assignment, shielding construction, or electrical interface levels, those parameters should be verified against the associated FI 820F and TB 870F documentation before replacement or wiring work.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What equipment does the ABB TK 821F connect?\u003c\/p\u003e\n\u003cp\u003eA: The cable connects an FI 820F interface to a TB 870F terminal block and supports two serial channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK 821F require field-installed connectors?\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied description specifies integral connectors as part of the prefabricated cable assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Is the TK 821F RoHS compliant?\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied ABB data explicitly identifies the product as not RoHS compliant.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the cable designation, product ID, and connector configuration before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the receiving equipment is the specified FI 820F interface and TB 870F terminal block.\u003c\/li\u003e\n\u003cli\u003eIsolate system power according to the applicable site maintenance procedure before making or removing connections.\u003c\/li\u003e\n\u003cli\u003eInspect both integral connectors for mechanical damage, contamination, or bent contacts.\u003c\/li\u003e\n\u003cli\u003eRoute the serial cable separately from high-current power conductors where practical to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends, excessive tensile loading, crushing, or repeated mechanical movement of the cable.\u003c\/li\u003e\n\u003cli\u003eDo not modify the prefabricated connector assembly unless ABB documentation explicitly permits modification.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify connector engagement and cable routing before restoring system power.\u003c\/li\u003e\n\u003cli\u003eCheck serial communication after installation and confirm that both intended channels operate correctly.\u003c\/li\u003e\n\u003cli\u003eUse the applicable ABB wiring documentation to verify pin assignments and shielding or grounding requirements because those details are not specified in the supplied product data.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612630052952,"sku":"TK821F 3BDM000150R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK821F-3BDM000150R1-3_1200x1200_de48bdb7-a0a2-4d81-b5dc-02ccbda49d79.jpg?v=1786959212"},{"product_id":"abb-tk811v150-s800-modulebus-optical-cable","title":"ABB TK811V150 S800 ModuleBus Optical Cable","description":"\u003ch2\u003eABB TK811V150 S800 ModuleBus Optical Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for optical ModuleBus communication in ABB S800 systems, the \u003cstrong\u003eABB TK811V150\u003c\/strong\u003e (\u003cstrong\u003eTK811V150\u003c\/strong\u003e Duplex Plastic Optical Fiber Cable) provides a 15 m physical optical link between compatible ModuleBus nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK811V150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSC950107R3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplex Plastic Optical Fiber Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eOptical ModuleBus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003ePlastic Optical Fiber (POF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003eDuplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003ePrefabricated connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Diameter\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.125 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15 m cable length; 5 mm cable diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOptical ModuleBus Communication\u003c\/h3\u003e\n\u003cp\u003eThe TK811V150 carries ModuleBus communication through a duplex plastic optical fiber path. Therefore, the communication link uses optical transmission rather than a copper electrical signal path.\u003c\/p\u003e\n\u003cp\u003eThe POF construction provides electrical isolation between connected nodes. In addition, the optical path does not form a conductive signal path for electromagnetic interference. Consequently, the cable can separate the communication medium from electrical noise sources associated with industrial control wiring.\u003c\/p\u003e\n\u003cp\u003eThe 15 m cable length defines the physical connection supplied by this model. Furthermore, the prefabricated construction reduces field termination work and preserves the specified connector arrangement.\u003c\/p\u003e\n\u003cp\u003eFor S800 installations, the cable functions as a physical ModuleBus interconnection component. However, the supplied data does not specify communication velocity, optical attenuation, wavelength, or receiver sensitivity, so these values should not be inferred from the model number.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TK811V150 require an electrical power connection?\u003c\/p\u003e\n\u003cp\u003eA: No. The TK811V150 is a passive optical cable and has no specified power consumption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the physical cable length?\u003c\/p\u003e\n\u003cp\u003eA: The TK811V150 has a specified cable length of 15 m.\u003c\/p\u003e\n\u003cp\u003eQ: Can the cable length or optical performance be extended by field splicing?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data identifies the product as a prefabricated cable. It does not specify field splicing procedures or permitted modifications. Therefore, installation should retain the supplied cable and connector configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the complete ABB part number, \u003cstrong\u003e3BSC950107R3\u003c\/strong\u003e, before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that both connected devices support the required optical ModuleBus interface.\u003c\/li\u003e\n\u003cli\u003eRoute the cable away from mechanical pinch points, sharp edges, and excessive bending.\u003c\/li\u003e\n\u003cli\u003eDo not pull the cable by its optical connectors during installation.\u003c\/li\u003e\n\u003cli\u003eKeep connector interfaces clean and protected from dust before mating.\u003c\/li\u003e\n\u003cli\u003eMaintain the factory-installed connector configuration unless ABB documentation explicitly permits modification.\u003c\/li\u003e\n\u003cli\u003eAvoid routing practices that place continuous mechanical stress on the fiber cable.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify that both optical connectors are fully seated and mechanically latched.\u003c\/li\u003e\n\u003cli\u003eIf communication faults occur, inspect connector seating, cable routing, visible damage, and fiber continuity before replacing system hardware.\u003c\/li\u003e\n\u003cli\u003eDo not assign an operating temperature, minimum bend radius, attenuation, or optical transmission limit unless the applicable ABB installation documentation specifies the value\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612639621208,"sku":"TK811V150 3BSC950107R3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK811V150-3BSC950107R3-3_1200x1200_607fe9d4-a81c-4057-8ae4-5b544ce0bbbd.jpg?v=1786959329"},{"product_id":"abb-3bsc950107r2-tk811v050-pof-cable","title":"ABB 3BSC950107R2 TK811V050 POF Cable","description":"\u003ch2\u003eABB 3BSC950107R2 TK811V050 POF Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for optical data transmission in ABB automation network connections, the \u003cstrong\u003eABB 3BSC950107R2\u003c\/strong\u003e (\u003cstrong\u003eTK811V050\u003c\/strong\u003e POF Cable) provides direct physical signal transmission through a 5 m duplex plastic optical fibre assembly with latching connectors.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BSC950107R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eTK811V050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePOF Cable, Duplex Plastic Fibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eLatching Duplex Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Diameter\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.045 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCable length: 5 m; Diameter: 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive optical cable, no electrical power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85447000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Ethernet and Optical Fibre Connectivity Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ABB TK811V050 is a passive optical interconnection component designed for ABB automation system communication assemblies. It transfers optical signals through duplex plastic fibre media and uses latching duplex connectors for secure mechanical retention.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the plastic optical fibre construction supports short-distance cabinet and system interconnections where electrical isolation between connected devices is required. The cable assembly contains no active electronic components and does not require firmware configuration.\u003c\/p\u003e\n\u003cp\u003eThe cable supports ABB system communication architectures that require optical media connection, including applications where backplane bus communication velocity and network signal integrity must be maintained across connected automation hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB 3BSC950107R2 cable require external power supply?\u003cbr\u003eA: No. The cable is a passive optical fibre assembly and does not consume electrical power during operation.\u003c\/p\u003e\n\u003cp\u003eQ: What connector configuration does the TK811V050 use?\u003cbr\u003eA: The TK811V050 uses a duplex plastic fibre cable configuration with latching duplex connectors.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be installed with standard copper communication wiring?\u003cbr\u003eA: No. This component is designed specifically for optical fibre connections and requires compatible ABB optical communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that both connected optical interfaces support plastic optical fibre communication before installation.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified cable routing path and avoid excessive mechanical stress on the fibre assembly.\u003c\/li\u003e\n\u003cli\u003eEnsure latching connectors are fully engaged to prevent accidental disconnection during cabinet operation.\u003c\/li\u003e\n\u003cli\u003eKeep connector surfaces clean before mating to reduce optical signal attenuation.\u003c\/li\u003e\n\u003cli\u003eSeparate optical cable routing from high-voltage power cables where possible to maintain proper cabinet wiring practice.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44618948575320,"sku":"TK811V050 3BSC950107R2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK811V0503BSC950107R2-3.jpg?v=1787036672"},{"product_id":"abb-tk811v015-3bsc950107r1-pof-cable","title":"ABB TK811V015 3BSC950107R1 POF Cable","description":"\u003ch2\u003eABB TK811V015 3BSC950107R1 POF Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TK811V015 3BSC950107R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3BSC950107R1\u003c\/strong\u003e POF Cable, operates as a dedicated optical communication component for duplex signal transmission within ABB S800 I\/O system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK811V015 3BSC950107R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplex Plastic Optical Fiber (POF) Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSC950107R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSC950107R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.4 x 7.6 x 25.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eDuplex Plastic Optical Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate Support\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive optical cable, no electrical power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e650 nm visible red light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation\u003c\/td\u003e\n\u003ctd\u003eMaximum 3.5 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eMinimum 5 MHz\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumerical Aperture\u003c\/td\u003e\n\u003ctd\u003e0.50 +\/- 0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Polarity\u003c\/td\u003e\n\u003ctd\u003eKeyed cross-over (Tx to Rx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eOrange PVC, UV-resistant and flame-retardant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBend Radius\u003c\/td\u003e\n\u003ctd\u003e15 mm static \/ 30 mm minimum dynamic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Load\u003c\/td\u003e\n\u003ctd\u003eMaximum 70 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Communication and Backplane Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe ABB TK811V015 3BSC950107R1 uses duplex plastic optical fiber technology to transfer communication signals between compatible ABB S800 system components. Therefore, the cable maintains optical isolation between connected devices while supporting industrial communication requirements.\u003c\/p\u003e\n\u003cp\u003eThe cable assembly provides keyed cross-over polarity, which defines the optical transmit and receive direction. In addition, the 650 nm visible light transmission design simplifies field identification and connection verification during installation.\u003c\/p\u003e\n\u003cp\u003eThe TK811V015 supports ABB industrial control infrastructure where backplane bus communication velocity and I\/O density scaling require stable physical communication links. Because the cable uses optical transmission, it avoids electrical interference effects commonly present in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the ABB TK811V015 3BSC950107R1?\u003c\/p\u003e\n\u003cp\u003eA: The TK811V015 is a 1.5 m duplex POF cable designed for optical communication connections in ABB S800 I\/O system installations.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK811V015 require external electrical power?\u003c\/p\u003e\n\u003cp\u003eA: No. The cable is a passive optical transmission component and does not consume electrical power.\u003c\/p\u003e\n\u003cp\u003eQ: What installation factors affect the optical signal performance?\u003c\/p\u003e\n\u003cp\u003eA: Proper connector alignment, correct Tx to Rx polarity, and maintaining the specified bend radius are required to preserve optical transmission performance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the connector keying before installation to maintain correct Tx to Rx optical polarity.\u003c\/li\u003e\n\u003cli\u003eInstall the cable without exceeding the specified static and dynamic bend radius limits.\u003c\/li\u003e\n\u003cli\u003eAvoid mechanical stress on the fiber jacket and connectors during routing.\u003c\/li\u003e\n\u003cli\u003eKeep the orange PVC jacket free from sharp edges, excessive pulling force, and abrasion points.\u003c\/li\u003e\n\u003cli\u003eConfirm connector cleanliness before mating the optical interfaces.\u003c\/li\u003e\n\u003cli\u003eRoute the cable separately from sources of mechanical damage or excessive heat exposure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44618972004440,"sku":"TK811V015 3BSC950107R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK811V0153BSC950107R1-3.jpg?v=1787036752"},{"product_id":"abb-3bdm000210r1-tk-807f-supply-cable","title":"ABB 3BDM000210R1 TK 807F Supply Cable","description":"\u003ch2\u003eABB 3BDM000210R1 TK 807F Supply Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BDM000210R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTK 807F\u003c\/strong\u003e Supply Cable, operates as a dedicated power connection component for AC supply distribution between SA 801F \/ SA 811F safety automation modules and their electrical supply network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BDM000210R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eTK 807F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eSupply Cable with Ferrules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e115\/230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eSA 801F \/ SA 811F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eFerrule Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Cable Integration and Electrical Connection\u003c\/h3\u003e\n\u003cp\u003eThe ABB TK 807F supply cable provides a prefabricated connection path for AC power distribution within ABB safety automation configurations. The cable uses ferrule terminations to support direct cabinet wiring and terminal block installation.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the 2 m cable length allows standardized routing between the supply source and SA 801F \/ SA 811F modules. The insulated conductor structure supports voltage levels up to 230 VAC according to the product specification.\u003c\/p\u003e\n\u003cp\u003eFor ABB industrial control systems, cable assemblies such as the TK 807F support I\/O density scaling by reducing field wiring preparation time and maintaining consistent termination methods. The cable design also supports organized cabinet layouts with defined power routing paths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What equipment is the ABB 3BDM000210R1 TK 807F designed to connect?\u003cbr\u003eA: The TK 807F is specified as a supply cable for SA 801F and SA 811F modules, providing 115\/230 VAC power connection through ferrule terminations.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK 807F include active electronic components?\u003cbr\u003eA: No. The TK 807F is a passive prefabricated cable assembly and does not contain processing, communication, or control electronics.\u003c\/p\u003e\n\u003cp\u003eQ: What termination method does the cable use?\u003cbr\u003eA: The cable uses ferrule terminations designed for industrial terminal connection and cabinet wiring applications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the TK 807F according to the wiring requirements of the connected ABB safety automation hardware.\u003c\/p\u003e\n\u003cp\u003eVerify the AC supply voltage level before connection and ensure correct terminal assignment during cabinet installation.\u003c\/p\u003e\n\u003cp\u003eRoute the cable separately from high-current switching conductors where possible to reduce electrical interference. Maintain proper cable bend radius and avoid mechanical stress on the ferrule ends.\u003c\/p\u003e\n\u003cp\u003eConfirm that all ferrule connections are fully inserted and mechanically secured before energizing the system. Use standard industrial grounding and shielding practices when the installation environment requires additional noise protection.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619001430104,"sku":"TK807F 3BDM000210R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK807F3BDM000210R1-3.jpg?v=1787036865"},{"product_id":"tk802f-3bdm000213r1-abb-s800-i-o-power-supply-cable","title":"TK802F 3BDM000213R1 ABB S800 I\/O Power Supply Cable","description":"\u003ch2\u003eABB TK802F 3BDM000213R1 Power Supply Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC power distribution in ABB AC 800F and S800 I\/O systems, the \u003cstrong\u003eABB TK802F 3BDM000213R1\u003c\/strong\u003e (\u003cstrong\u003eTK802F\u003c\/strong\u003e Power Supply Cable) provides direct physical electrical connection between power supply units and automation hardware assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK802F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Order Code\u003c\/td\u003e\n\u003ctd\u003e3BDM000213R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCable length: 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly; no independent power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003ePre-fabricated cable with wire ferrules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eABB AC 800F controllers, S800 I\/O modules, SD802F and SD812F power distribution assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Control System Cable Integration\u003c\/h3\u003e\n\u003cp\u003eThe TK802F cable assembly supports ABB PLC and DCS hardware architectures by providing a prepared electrical interface for 24 VDC system power connections. Therefore, it reduces field wiring operations and maintains consistent terminal identification during cabinet installation.\u003c\/p\u003e\n\u003cp\u003eFor ABB automation platforms, the cable supports structured power distribution layouts where backplane bus communication velocity, I\/O density scaling, and cabinet-level wiring organization are controlled by the host hardware design. The cable itself functions as a passive electrical component and does not process communication signals or execute firmware functions.\u003c\/p\u003e\n\u003cp\u003eThe ferrule-equipped conductors provide a defined termination method for industrial terminal blocks. Additionally, installation practices should maintain proper cable routing separation from high-energy switching circuits to reduce electrical interference exposure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB TK802F 3BDM000213R1 cable provide communication functions?\u003cbr\u003eA: No. The TK802F is a passive power supply cable assembly designed for electrical power connection. It does not provide data communication or protocol conversion.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TK802F be used with ABB S800 I\/O power supply modules?\u003cbr\u003eA: Yes. The cable is specified for ABB S800 I\/O related power distribution applications, including SD802F and SD812F assemblies.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK802F require firmware configuration after installation?\u003cbr\u003eA: No. The cable contains no programmable electronics and requires no firmware update or software configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the 24 VDC power source rating before connecting the cable assembly.\u003c\/li\u003e\n\u003cli\u003eInstall the ferrule terminals according to the corresponding ABB terminal block wiring diagram.\u003c\/li\u003e\n\u003cli\u003eKeep the cable separated from high-current motor wiring and switching power conductors where possible.\u003c\/li\u003e\n\u003cli\u003eMaintain correct polarity during DC power connection to prevent equipment damage.\u003c\/li\u003e\n\u003cli\u003eConfirm mechanical retention of all terminal connections before system energization.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619012046936,"sku":"TK802F 3BDM000213R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK802F3BDM000213R1-3.jpg?v=1787037015"},{"product_id":"tk801v006-3bsc950089r2-abb-advant-ocs-800xa-modulebus-extension-cable","title":"TK801V006 3BSC950089R2 ABB Advant OCS 800xA ModuleBus Extension Cable","description":"\u003ch2\u003eABB TK801V006 3BSC950089R2 ModuleBus Extension Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for ModuleBus physical extension in S800 I\/O systems, the \u003cstrong\u003eABB TK801V006 3BSC950089R2\u003c\/strong\u003e (\u003cstrong\u003eTK801V006\u003c\/strong\u003e ModuleBus Extension Cable) provides direct electrical connection between TB805\/TB845 or TB806\/TB846 terminal units to extend I\/O module installation across separate DIN rails.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK801V006 3BSC950089R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModuleBus Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSC950089R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 x 2.5 x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable connection, no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Platform\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD SUB 25 male\/female connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eShielded extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eModuleBus signal extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate Support\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Units\u003c\/td\u003e\n\u003ctd\u003eTB805\/TB845 and TB806\/TB846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 ModuleBus Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TK801V006 extends the electrical ModuleBus connection while maintaining communication between S800 I\/O modules installed on different DIN rails. The cable uses a shielded D SUB 25 interface to transfer ModuleBus signals between terminal units.\u003c\/p\u003e\n\u003cp\u003eFurthermore, ABB S800 architecture uses a dedicated backplane-style communication structure for I\/O module data exchange. The TK801V006 supports ModuleBus extension requirements without adding active electronic conversion components or external communication nodes.\u003c\/p\u003e\n\u003cp\u003eThe cable design supports physical separation of I\/O assemblies while keeping the same ModuleBus network segment. Therefore, system designers can distribute S800 I\/O modules according to cabinet layout and installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the main function of the ABB TK801V006 cable?\u003cbr\u003eA: The TK801V006 extends the electrical ModuleBus connection between compatible ABB S800 terminal units, allowing I\/O modules to be mounted on different DIN rails.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK801V006 require an external power supply?\u003cbr\u003eA: No. The TK801V006 is a passive shielded extension cable and does not require independent power input.\u003c\/p\u003e\n\u003cp\u003eQ: Which terminal units are compatible with the TK801V006?\u003cbr\u003eA: The cable is designed for use with ABB TB805\/TB845 and TB806\/TB846 terminal units within S800 I\/O installations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TK801V006 between compatible ModuleBus terminal units according to ABB S800 system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eVerify that the D SUB 25 male and female connectors match the corresponding terminal unit interfaces before installation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing to avoid mechanical stress, excessive bending, and interference from high-power electrical conductors.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shield according to the cabinet grounding design to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eConfirm ModuleBus communication after installation through the automation system engineering tools.\u003c\/li\u003e\n\u003cli\u003eAvoid installing the extension cable near strong electromagnetic interference sources without appropriate shielding measures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619062968408,"sku":"TK801V006 3BSC950089R2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK801V0063BSC950089R2-3.jpg?v=1787037205"},{"product_id":"tk801v003-3bsc950089r1-abb-advant-s800-i-o-modulebus-extension-cable","title":"TK801V003 3BSC950089R1 ABB Advant S800 I\/O ModuleBus Extension Cable","description":"\u003ch2\u003eABB TK801V003 3BSC950089R1 ModuleBus Extension Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for ModuleBus signal extension in ABB S800 I\/O systems, the \u003cstrong\u003eABB TK801V003 3BSC950089R1\u003c\/strong\u003e (\u003cstrong\u003eTK801V003\u003c\/strong\u003e ModuleBus Extension Cable) provides direct physical connection between separated I\/O module assemblies through a shielded D-SUB 25 interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK801V003 3BSC950089R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModuleBus Extension Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSC950089R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 x 7.6 x 12.7 cm (shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable connection, no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD-SUB 25 male-female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eShielded cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate Support\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eModuleBus extension between ABB S800 I\/O assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 ModuleBus Communication Extension\u003c\/h3\u003e\n\u003cp\u003eThe TK801V003 cable supports ABB industrial control architectures by extending the S800 ModuleBus physical connection. Furthermore, the shielded cable design maintains signal integrity during communication between connected I\/O modules.\u003c\/p\u003e\n\u003cp\u003eABB S800 systems use ModuleBus communication for distributed I\/O management. The cable enables installation flexibility by allowing I\/O components connected to the same electrical ModuleBus network to be positioned on different DIN rails.\u003c\/p\u003e\n\u003cp\u003eThe extension cable uses a D-SUB 25 male-female interface and maintains the required electrical connection path for ModuleBus communication. Additionally, the cable construction supports ABB I\/O density scaling by allowing expanded module placement within the same control configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the ABB TK801V003 cable?\u003cbr\u003eA: The TK801V003 extends the ABB S800 ModuleBus connection between I\/O module assemblies using a shielded D-SUB 25 male-female cable interface.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK801V003 require an external power supply?\u003cbr\u003eA: No. The TK801V003 is a passive extension cable and does not require an external power connection.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TK801V003 be used for separated DIN rail installations?\u003cbr\u003eA: Yes. The cable supports ModuleBus extension applications where ABB S800 I\/O modules require physical separation between mounting locations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the cable according to ABB S800 system installation requirements and ModuleBus connection procedures.\u003c\/li\u003e\n\u003cli\u003eVerify that the D-SUB 25 male and female connectors match the corresponding ModuleBus interfaces before installation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing to avoid mechanical stress, sharp bending, and interference from high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shield according to the control cabinet grounding practice to maintain electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003eConfirm ModuleBus communication status after installation through the ABB system engineering tools.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619096653912,"sku":"TK801V003 3BSC950089R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK801V0033BSC950089R1-3.jpg?v=1787037349"},{"product_id":"abb-dos810-3bse078768r1-digital-output-signal-conditioning-module","title":"ABB DOS810 3BSE078768R1 Digital Output Signal Conditioning Module","description":"\u003ch2\u003eABB DOS810 3BSE078768R1 Digital Output Signal Conditioning Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DOS810 3BSE078768R1\u003c\/strong\u003e serves as the primary \u003cstrong\u003eDOS810\u003c\/strong\u003e Digital Output Signal Conditioning Module utilized to execute 24 V DC \/ 0.6 A output switching tasks across ABB Ability System 800xA Select I\/O platforms. The module provides one-channel signal conditioning, field device powering, diagnostics, redundancy support, and hot-swap capability for 2-wire devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDOS810 3BSE078768R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Signal Conditioning Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB Ability System 800xA Select I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e73 g including base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 77.9 mm, Depth 105 mm, Height 9.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.36 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Field Devices\u003c\/td\u003e\n\u003ctd\u003e2-wire devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation to system, factory routine tested at 3060 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power\u003c\/td\u003e\n\u003ctd\u003eCurrent limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Input Robustness\u003c\/td\u003e\n\u003ctd\u003e+\/-35 V between all terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e40 to 5000 ohm, maximum inductor time constant L\/R 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLoop supervision, internal hardware supervision, communication supervision, internal power supervision, power injection supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Installation\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS Barrier\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61000-6-4, IEC\/EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1-12, IEC\/EN 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DOS810 operates within the ABB Select I\/O architecture, where Ethernet networked I\/O modules separate field termination functions from controller-level configuration. Therefore, the module supports flexible cabinet design by allowing single-channel I\/O placement independent from traditional centralized marshalling structures.\u003c\/p\u003e\n\u003cp\u003eThe Select I\/O platform applies I\/O density scaling through distributed signal conditioning modules. Furthermore, the DOS810 supports redundant configurations and hot-swap replacement procedures to maintain system availability during maintenance activities.\u003c\/p\u003e\n\u003cp\u003eThe module performs digital output conditioning between the automation system and connected 2-wire field devices. It provides galvanic isolation between the system side and field side while maintaining supervised output operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB DOS810 support hot swapping during system operation?\u003cbr\u003eA: Yes. The DOS810 supports hot swap replacement within the Select I\/O architecture. Actual replacement procedures must follow ABB system maintenance instructions and application configuration requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field devices can connect to the DOS810?\u003cbr\u003eA: The DOS810 supports 2-wire field devices requiring a 24 V DC \/ 0.6 A digital output signal interface.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic functions are available on the DOS810?\u003cbr\u003eA: The module provides loop supervision for short circuit and open circuit conditions, internal hardware monitoring, communication supervision, internal power supervision, and power injection supervision.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DOS810 module within the ABB Select I\/O mechanical system according to the approved cabinet layout.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring matches the specified 24 V DC digital output requirements before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eMaintain correct separation between field signal wiring and high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shields according to the site grounding design and applicable EMC installation practices.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal wiring polarity before commissioning connected 2-wire devices.\u003c\/li\u003e\n\u003cli\u003eEnsure environmental conditions remain within the specified operating temperature, humidity, and pollution limits.\u003c\/li\u003e\n\u003cli\u003eUse approved hazardous area installation procedures when applying the module in classified locations.\u003c\/li\u003e\n\u003cli\u003ePerform loop supervision and output verification tests after installation completion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619130929240,"sku":"DOS810 3BSE078768R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DOS810-3BSE078768R1-2_1200x1200_50c7f99b-207c-46bc-80b8-c47f58b32813.jpg?v=1787037482"},{"product_id":"do890-3bsc690074r1-abb-digital-output-modules","title":"DO890 3BSC690074R1 ABB Digital Output Modules","description":"\u003ch2\u003eABB DO890 Digital Output IS 4 ch\u003c\/h2\u003e\n\u003cp\u003eConfigured for intrinsic safety digital signal switching in ABB System 800xA I\/O environments, the \u003cstrong\u003eABB 3BSC690074R1\u003c\/strong\u003e (\u003cstrong\u003eDO890\u003c\/strong\u003e Digital Output IS 4 ch) provides direct electrical execution through four individually galvanically isolated output channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Product ID\u003c\/td\u003e\n\u003ctd\u003e3BSC690074R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI-O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eDigital Output Intrinsic Safety Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channel Type\u003c\/td\u003e\n\u003ctd\u003eDO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually galvanic isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module Termination Unit\u003c\/td\u003e\n\u003ctd\u003eTU890 or TU891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm x 119 mm x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eCategory 5 Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Bus and I\/O Density Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ABB DO890 belongs to the System 800xA Select I\/O family and provides a digital output interface designed for intrinsic safety applications. The module manages four output channels with individual galvanic isolation, reducing electrical interaction between field circuits.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module supports ABB I\/O density scaling concepts by allowing standardized I\/O cabinet configurations through dedicated Module Termination Units. The TU890 or TU891 provides the field connection interface, while the DO890 performs signal processing between the control system and connected intrinsic safety circuits.\u003c\/p\u003e\n\u003cp\u003eThe module integrates with ABB industrial control architectures using ABB I\/O communication structures. Therefore, engineering teams can maintain consistent module replacement and configuration practices within compatible System 800xA installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many output channels does the ABB DO890 provide?\u003cbr\u003eA: The DO890 provides four digital output channels. Each channel includes individual galvanic isolation for intrinsic safety interface applications.\u003c\/p\u003e\n\u003cp\u003eQ: Which termination units are compatible with the DO890 module?\u003cbr\u003eA: The DO890 is designed for use with ABB Module Termination Units TU890 or TU891.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DO890 provide channel-to-channel electrical isolation?\u003cbr\u003eA: Yes. The module specification states that each output channel has individual galvanic isolation to separate connected field circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DO890 module according to ABB System 800xA hardware installation procedures.\u003c\/li\u003e\n\u003cli\u003eUse the specified TU890 or TU891 Module Termination Unit for field wiring connections.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring matches the intrinsic safety requirements of the connected equipment.\u003c\/li\u003e\n\u003cli\u003eSeparate intrinsic safety wiring from non-intrinsic safety circuits according to site electrical standards.\u003c\/li\u003e\n\u003cli\u003eCheck module seating, terminal connections, and grounding arrangements before system commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm I\/O configuration parameters in the control system before enabling field outputs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619167727704,"sku":"DO890 3BSC690074R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO890-3BSC690074R1-3_1200x1200_c792d256-ad1f-429b-8241-ca5162631fd9.jpg?v=1787037595"},{"product_id":"do880-3bse028602r1-abb-s800-i-o-digital-output-module","title":"DO880 3BSE028602R1 ABB S800 I\/O Digital Output Module","description":"\u003ch2\u003eABB DO880 3BSE028602R1 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high integrity digital signal switching in ABB System 800xA and safety controller environments, the \u003cstrong\u003eABB 3BSE028602R1\u003c\/strong\u003e (\u003cstrong\u003eDO880\u003c\/strong\u003e Digital Output Module) provides direct electrical execution for 24 VDC output channels with SIL3 certified safety operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE028602R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm depth x 119 mm height x 45 mm width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output (DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Classification\u003c\/td\u003e\n\u003ctd\u003eSIL3 certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Mode\u003c\/td\u003e\n\u003ctd\u003eSingle or redundant operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Termination Units\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830, TU833, TU842, TU843, TU852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Control and Safety I\/O Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DO880 module integrates into ABB S800 I\/O systems and supports high integrity digital output control. It provides 16 output channels for switching external field devices through 24 VDC circuits.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module supports single and redundant configurations according to safety system requirements. The installation must follow the ABB Safety Manual configuration rules to maintain SIL3 safety performance.\u003c\/p\u003e\n\u003cp\u003eThe module operates within ABB backplane bus communication structures, where I\/O density scaling allows multiple signal modules to be arranged within System 800xA automation platforms. In addition, firmware flash compatibility and controller configuration parameters must match the installed automation system version.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the DO880 operate in both single and redundant configurations?\u003cbr\u003eA: Yes. The DO880 supports single or redundant operation modes. The selected configuration must follow ABB safety manual requirements.\u003c\/p\u003e\n\u003cp\u003eQ: Which Module Termination Units are compatible with the DO880?\u003cbr\u003eA: The DO880 can be installed with TU810, TU812, TU814, TU830, TU833, TU842, TU843, and TU852 termination units.\u003c\/p\u003e\n\u003cp\u003eQ: How many digital output channels does the DO880 provide?\u003cbr\u003eA: The module provides 16 digital output channels with 24 VDC, 0.5 A output capability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DO880 module using the specified ABB Module Termination Unit before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eVerify that the safety configuration matches the approved ABB Safety Manual requirements before system commissioning.\u003c\/li\u003e\n\u003cli\u003eSeparate digital output wiring from high voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding standard and automation system installation rules.\u003c\/li\u003e\n\u003cli\u003eConfirm redundant wiring paths and terminal assignments before applying field power.\u003c\/li\u003e\n\u003cli\u003eCheck controller hardware configuration and firmware compatibility before replacing or adding modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619183784024,"sku":"DO880 3BSE028602R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO880-3BSE028602R1-3_1200x1200_a7cba8bd-032c-4f27-a933-592e2f1bc5b2.jpg?v=1787038074"},{"product_id":"digital-output-module-abb-s800-i-o-do828-3bse069055r2","title":"Digital Output Module ABB S800 I\/O DO828 3BSE069055R2","description":"\u003ch2\u003eABB DO828 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE069055R1 DO828\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO828\u003c\/strong\u003e Digital Output Module, provides relay-based switching execution for 125 VDC and 250 VAC field circuits within the ABB S800 I\/O system. The module contains 16 individually isolated relay output channels with optical isolation, relay drivers, status indication, and EMC protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO828\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE069055R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output, Normally Open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e5 to 125 VDC \/ 5 to 250 VAC, maximum 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eMaximum 125 VDC \/ 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channel-to-channel and circuit common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTU Compatibility\u003c\/td\u003e\n\u003ctd\u003eTU851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm width x 102 mm depth x 119 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC: 45 mA; +24 VDC: 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 VDC Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4 and EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Relay Output Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DO828 uses the ABB S800 I\/O backplane communication structure for module control and diagnostics. Each output channel contains an optical isolation barrier, relay driver stage, relay switching element, output LED indication, and EMC protection components.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control circuits requiring isolated relay contacts. Additionally, the relay supply voltage supervision monitors the 12 V distribution from the ModuleBus. If the relay supply disappears, the module generates an error signal and activates the Warning LED. The supervision function can be enabled or disabled through configuration parameters.\u003c\/p\u003e\n\u003cp\u003eThe S800 I\/O platform provides modular I\/O density scaling through distributed ModuleBus communication. Therefore, the DO828 integrates directly with ABB controller systems using standardized I\/O addressing and diagnostic handling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB DO828 provide channel-to-channel isolation?\u003cbr\u003eA: Yes. Each of the 16 relay output channels provides individual isolation between channels and the circuit common.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DO828 require an external 24 VDC field supply?\u003cbr\u003eA: No. The module specifies 0 mA external +24 VDC consumption. Relay supply monitoring uses the 12 V distribution available through the ModuleBus.\u003c\/p\u003e\n\u003cp\u003eQ: Which ABB Module Termination Unit is compatible with the DO828?\u003cbr\u003eA: The DO828 is designed for use with the ABB TU851 Module Termination Unit and uses the ED keying code.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DO828 module on the ABB S800 I\/O mounting arrangement with the specified TU851 Module Termination Unit. Verify that the module keying code matches the installed MTU before commissioning.\u003c\/p\u003e\n\u003cp\u003eConnect relay output field wiring according to the specified voltage and current limits. Maintain separation between relay output wiring and sensitive signal cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConfirm protective grounding, cabinet bonding, and EMC installation practices before applying field power. Check front LED indicators after startup to verify module operation, channel status, and relay supply supervision status.\u003c\/p\u003e\n\u003cp\u003eEnsure ambient temperature, humidity, pollution degree, and enclosure conditions remain within the specified operating limits.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619255939160,"sku":"DO828 3BSE069055R2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO8283BSE069055R2-3.jpg?v=1787038369"},{"product_id":"do828-3bse069055r1-abb-s800-i-o-digital-output-relay-module","title":"DO828 3BSE069055R1 ABB S800 I\/O Digital Output Relay Module","description":"\u003ch2\u003eABB DO828 Digital Output Relay Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DO828 3BSE069055R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO828\u003c\/strong\u003e Digital Output Relay Module, executes isolated relay switching operations for S800 I\/O systems through 16 channel discrete output interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO828 3BSE069055R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 45 mm, Depth 102 mm, 111 mm including connector, Height 119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eRelay output, normally open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 to 125 VDC \/ 5 to 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channel-to-channel and channel-to-circuit common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible MTU\u003c\/td\u003e\n\u003ctd\u003eTU851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +5 V\u003c\/td\u003e\n\u003ctd\u003e45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +24 V\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 V Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Relay Output Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DO828 integrates relay driver circuits, optical isolation barriers, output status LEDs, relays, and EMC protection components on each output channel. Therefore, every relay output maintains electrical separation between channels and the common circuit reference.\u003c\/p\u003e\n\u003cp\u003eThe module receives relay supply supervision through the 12 V distribution available on the ModuleBus. Additionally, the supervision circuit generates module error information when the relay supply voltage disappears. The warning LED indicates the detected condition, and the diagnostic status transfers through the ModuleBus communication interface.\u003c\/p\u003e\n\u003cp\u003eThe DO828 supports industrial control applications requiring isolated switching of AC and DC loads. Furthermore, the module provides channel-level status indication through front panel LEDs for fault, run, OSP, and individual channel states.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB DO828 support channel-to-channel electrical isolation?\u003cbr\u003eA: Yes. The DO828 provides individual isolation between channels and between channels and the circuit common.\u003c\/p\u003e\n\u003cp\u003eQ: What type of loads can the DO828 relay outputs control?\u003cbr\u003eA: The module supports relay-based switching for loads up to 125 VDC or 250 VAC with a maximum continuous current of 2 A per channel.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module detect relay supply voltage failure?\u003cbr\u003eA: The DO828 monitors the 12 V relay supply converter from the ModuleBus and reports module error and warning conditions through the S800 I\/O diagnostic system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DO828 on an ABB S800 I\/O assembly with the specified TU851 Module Termination Unit. Verify that the MTU keying code matches the module configuration before insertion.\u003c\/p\u003e\n\u003cp\u003eRoute field wiring separately from high-energy switching cables to reduce electromagnetic interference. Maintain correct terminal identification during relay load connection because incorrect wiring can affect switching behavior.\u003c\/p\u003e\n\u003cp\u003eConnect protective grounding according to the installation requirements of the control cabinet. Ensure that enclosure protection, environmental conditions, and cable routing follow IEC\/EN 61131-2 installation practices.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify relay output states through the S800 I\/O diagnostic interface and confirm LED status indications for each connected channel.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619334910040,"sku":"DO828 3BSE069055R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO828-3BSE069055R1-2_1200x1200_81734004-41a9-4e00-b653-05a4b31090a3.jpg?v=1787038551"},{"product_id":"do821-3bse013250r1-abb-s800-i-o-digital-output-relay-module","title":"DO821 3BSE013250R1 ABB S800 I\/O Digital Output Relay Module","description":"\u003ch2\u003eABB DO821 Digital Output Relay Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE013250R1 DO821\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO821\u003c\/strong\u003e Digital Output Relay Module, provides 230 V AC\/DC relay switching execution within the ABB S800 I\/O system. The module contains 8 individually isolated NC relay output channels with field voltage supervision and ModuleBus diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE013250R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eRelay (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e230 V AC\/DC, 5-250 V AC\/DC, 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channel-to-channel and to circuit common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Output Current\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003eSupported through MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003eTypical 2.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +5 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V External\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm W x 119 mm H x 102 mm D, 111 mm D including connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible MTU\u003c\/td\u003e\n\u003ctd\u003eTU811, TU813, TU831, TU836, TU837, TU851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 ModuleBus Relay Output Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe DO821 uses optical isolation barriers, relay drivers, output status LEDs, relay contacts, and EMC protection components for each output channel. Additionally, the module monitors the relay supply voltage derived from the 24 V ModuleBus distribution.\u003c\/p\u003e\n\u003cp\u003eThe relay power converter supervision generates a module error signal when the supply voltage disappears. Furthermore, the Warning LED indicates the abnormal condition, and the diagnostic information remains available through the ModuleBus communication interface. The supervision function can be enabled or disabled through configuration parameters.\u003c\/p\u003e\n\u003cp\u003eThe S800 I\/O architecture supports high I\/O density scaling through standardized ModuleBus communication. Therefore, the DO821 integrates directly into ABB distributed control environments where deterministic I\/O update behavior and channel-level isolation are required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DO821 support redundant output operation?\u003cbr\u003eA: No. The DO821 is a non-redundant digital output module with 8 individually isolated NC relay channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module detect relay supply failures?\u003cbr\u003eA: The module monitors the 24 V ModuleBus-derived relay supply voltage and reports faults through ModuleBus diagnostics when the voltage disappears.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DO821 outputs be connected to mixed AC and DC field loads?\u003cbr\u003eA: The module supports 5-250 V AC\/DC relay switching signals within the specified output voltage and current limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DO821 on approved ABB S800 I\/O mounting components with the specified compatible MTU. Verify the keying code before module insertion to prevent incorrect hardware installation.\u003c\/p\u003e\n\u003cp\u003eRoute field wiring separately from high-voltage power cables and maintain proper cable segregation according to industrial control cabinet practices. Connect protective earth and shielding according to the cabinet grounding design.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, check relay output wiring, channel status LEDs, ModuleBus communication status, and relay supply supervision parameters. Confirm that connected field devices remain within the rated voltage and current limits.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619412996184,"sku":"DO821 3BSE013250R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO821-3BSE013250R1_1200x1200_2160dd65-0932-4fb1-840b-be7c6dddde5e.jpg?v=1787038924"},{"product_id":"do820-3bse008514r1-abb-s800-i-o-digital-output-relay-module","title":"DO820 3BSE008514R1  ABB S800 I\/O Digital Output Relay Module","description":"\u003ch2\u003eABB DO820 3BSE008514R1 Digital Output Relay Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for relay-based digital switching in ABB S800 I\/O systems, the \u003cstrong\u003eABB DO820 3BSE008514R1\u003c\/strong\u003e (\u003cstrong\u003eDO820\u003c\/strong\u003e Digital Output Relay Module) provides direct electrical execution through individually galvanic isolated relay channels. The module handles 8 relay outputs with 24-230 VAC\/DC signal capability and 3 A maximum output current.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO820 3BSE008514R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 x 10.5 x 12 cm (shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 2.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNormally Open (N.O.) relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24-230 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Output Current\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Recording Accuracy\u003c\/td\u003e\n\u003ctd\u003e-0 ms \/ +1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +5 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Relay Output Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DO820 3BSE008514R1 uses the ABB S800 I\/O platform backplane communication structure for module data exchange and output control. The module contains 8 individually isolated relay output channels, and each channel provides electrical separation between the control system interface and field wiring.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the S800 I\/O architecture supports I\/O density scaling through modular channel expansion. The DO820 receives control commands through the ModuleBus interface and converts digital signals into relay contact switching actions for connected field devices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB DO820 3BSE008514R1 provide channel-to-channel isolation?\u003cbr\u003eA: Yes. Each relay output channel uses individual galvanic isolation to separate field circuits and reduce electrical interaction between channels.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field signals can the DO820 handle?\u003cbr\u003eA: The module supports relay output switching for 24-230 VAC\/DC field circuits with a maximum continuous current rating of 3 A per channel.\u003c\/p\u003e\n\u003cp\u003eQ: What is the ModuleBus power consumption of the DO820?\u003cbr\u003eA: The module consumes 60 mA from the +5 V ModuleBus supply and 140 mA from the +24 V ModuleBus supply.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DO820 module on an ABB S800 I\/O mounting arrangement with correct ModuleBus connection.\u003c\/li\u003e\n\u003cli\u003eVerify field voltage levels before connecting relay output terminals.\u003c\/li\u003e\n\u003cli\u003eSeparate high-voltage field wiring from low-level signal wiring according to site electrical installation standards.\u003c\/li\u003e\n\u003cli\u003eUse appropriate cable routing methods to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal connections and insulation conditions before energizing the output circuits.\u003c\/li\u003e\n\u003cli\u003eCheck relay output states through system diagnostics after installation completion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619434328152,"sku":"DO820 3BSE008514R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO820-3BSE008514R1-3_1200x1200_a68eff4a-44f3-4445-878f-a0a5d3f07900.jpg?v=1787039034"},{"product_id":"do818-3bse069053r1-abb-advant-ac800m-digital-output-module","title":"DO818 3BSE069053R1 ABB Advant AC800M Digital Output Module","description":"\u003ch2\u003eABB DO818 3BSE069053R1 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC transistor output execution in the ABB S800 I\/O system, the \u003cstrong\u003eABB DO818 3BSE069053R1\u003c\/strong\u003e (\u003cstrong\u003eDO818\u003c\/strong\u003e Digital Output Module) provides direct physical and electrical control of field devices through 32 current sourcing output channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO818 3BSE069053R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC (12 - 32 VDC), 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sourcing, current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Group Isolation\u003c\/td\u003e\n\u003ctd\u003eTwo isolated groups of 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.32 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 2.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +5 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003eTypical 70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V External\u003c\/td\u003e\n\u003ctd\u003e40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 x 11 x 11.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Output Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DO818 3BSE069053R1 integrates into the ABB S800 I\/O architecture through ModuleBus communication and provides high-density digital output control. Each output channel uses a high-side driver with short-circuit protection, over-temperature protection, EMC protection components, inductive load suppression, and optical isolation from the ModuleBus.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module divides the 32 outputs into two individually isolated groups of 16 channels. Each group includes a process voltage supervision input to monitor external field supply conditions. The output drivers provide current limiting functions for connected DC loads and maintain controlled switching behavior during field operation.\u003c\/p\u003e\n\u003cp\u003eThe ABB S800 platform supports I\/O density scaling through modular backplane communication. Therefore, the DO818 enables compact installation for distributed control configurations requiring multiple 24 VDC switching points.\u003c\/p\u003e\n\u003ch3\u003eFirmware and ModuleBus Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DO818 uses ABB S800 I\/O ModuleBus communication for data exchange with the controller system. The module transfers output status information and diagnostic signals through the ModuleBus interface.\u003c\/p\u003e\n\u003cp\u003eIn addition, the S800 I\/O family provides firmware flash compatibility management through the engineering configuration environment. The DO818 configuration must match the installed controller and I\/O system revision requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many output channels does the ABB DO818 3BSE069053R1 provide?\u003cbr\u003eA: The DO818 provides 32 digital output channels arranged as two isolated groups of 16 channels.\u003c\/p\u003e\n\u003cp\u003eQ: What output protection functions are included in the DO818 module?\u003cbr\u003eA: Each output channel includes short-circuit protection, over-temperature protection, current limiting, EMC protection, and inductive load suppression.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DO818 require an external 24 VDC field supply?\u003cbr\u003eA: Yes. The module uses an external 24 VDC process supply for field outputs, with a typical external current consumption of 40 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DO818 module on the ABB S800 I\/O carrier according to the approved system installation procedure.\u003c\/li\u003e\n\u003cli\u003eVerify that the ModuleBus connection is correctly seated before applying system power.\u003c\/li\u003e\n\u003cli\u003eConfirm field wiring polarity before connecting 24 VDC output devices.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding standard where shielded field cables are used.\u003c\/li\u003e\n\u003cli\u003eCheck output load ratings before energizing connected actuators, relays, or DC devices.\u003c\/li\u003e\n\u003cli\u003eVerify process voltage supervision signals before placing the module into normal operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619442028632,"sku":"DO818 3BSE069053R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO818-3BSE069053R1-3_1200x1200_9e6c22f2-96d2-4b73-865a-3dae4ef05265.jpg?v=1787039131"},{"product_id":"do815-3bse013258r1-abb-s800-i-o-digital-output-module","title":"DO815 3BSE013258R1 ABB  S800 I\/O Digital Output Module","description":"\u003ch2\u003eABB DO815 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DO815 3BSE013258R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO815\u003c\/strong\u003e Digital Output Module, provides 24 VDC high side switching execution within the ABB S800 I\/O system. The module controls eight digital output channels with short circuit protection, overload protection, and channel status monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO815 3BSE013258R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm W x 102 mm D x 119 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC (10 to 32 VDC), 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eHigh side driver, current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroupwise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.25 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003eShort circuit proof current limited output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus +5 V Current Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 120 mA, Max. 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus +24 V Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 V Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront LED Indicators\u003c\/td\u003e\n\u003ctd\u003eFault, Run, Warning, OSP, Channel 1-8 Status, Channel 1-8 Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupervision Functions\u003c\/td\u003e\n\u003ctd\u003eShort circuit, overload, undervoltage, open load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTU Compatibility\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O High Side Driver and Protection Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe DO815 uses eight individually controlled high side output drivers for 24 VDC field devices. Each channel integrates optical isolation, output status indication, EMC protection, and inductive load suppression components.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module divides the outputs into two isolated groups with four channels per group. The integrated protection circuits detect short circuits, overload conditions, undervoltage states, and active signal open load conditions.\u003c\/p\u003e\n\u003cp\u003eThe DO815 follows ABB S800 I\/O backplane communication architecture and supports I\/O density scaling through ModuleBus connectivity. The module provides direct digital signal execution between the control system and connected field actuators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of output driver does the ABB DO815 use?\u003cbr\u003eA: The DO815 uses a high side driver with current limiting. Each output channel includes short circuit and overload protection.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DO815 support redundant operation or safety integrity functions?\u003cbr\u003eA: No. The DO815 does not provide redundancy or high integrity functions. It operates as a standard digital output module within the S800 I\/O platform.\u003c\/p\u003e\n\u003cp\u003eQ: How are output channels electrically isolated?\u003cbr\u003eA: The eight outputs are arranged into two isolated groups. Each group contains four output channels and is isolated from ground.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DO815 module in an ABB S800 I\/O configuration using compatible Module Termination Units such as TU810, TU812, TU814, or TU830.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring according to the approved ABB installation documentation. Keep output signal wiring separated from high voltage power conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify the ModuleBus connection before system commissioning. Confirm that field devices match the 24 VDC output range and maximum current specification.\u003c\/p\u003e\n\u003cp\u003eEnsure protective grounding, enclosure requirements, and environmental conditions comply with the applicable IEC and installation standards.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619454709848,"sku":"DO815 3BSE013258R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO815-3BSE013258R1-3_1200x1200_985f03ad-e15d-4b33-9d68-e57e26443395.jpg?v=1787039255"},{"product_id":"do814-3bur001455r1-abb-advant-s800-i-o-digital-output-module","title":"DO814 3BUR001455R1 ABB Advant S800 I\/O Digital Output Module","description":"\u003ch2\u003eABB DO814 3BUR001455R1 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC current sinking output execution in the ABB S800 I\/O system, the \u003cstrong\u003eABB DO814 3BUR001455R1\u003c\/strong\u003e (\u003cstrong\u003eDO814\u003c\/strong\u003e Digital Output Module) provides direct physical signal control through 16 output channels with current limiting protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO814 3BUR001455R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 x 5.1 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC (12-32 VDC), 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking, current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O System\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA at +5 V ModuleBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Backplane and I\/O Density Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe DO814 operates as an ABB S800 I\/O digital output device with 16 current sinking channels. The module receives control commands through the ModuleBus interface and transfers discrete output signals to connected field devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the S800 I\/O architecture supports I\/O density scaling through modular channel allocation. The DO814 provides compact digital output expansion for systems requiring multiple 24 VDC discrete actuators, solenoids, and control circuits.\u003c\/p\u003e\n\u003cp\u003eThe module uses current limiting output technology to control load current and protect output channels against abnormal electrical conditions. Therefore, field wiring design must consider load characteristics and cable routing requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What output signal type does the ABB DO814 3BUR001455R1 provide?\u003cbr\u003eA: The DO814 provides 16 digital output channels using 24 VDC current sinking signals with current limiting functionality.\u003c\/p\u003e\n\u003cp\u003eQ: What ABB platform supports the DO814 module?\u003cbr\u003eA: The DO814 is designed for the ABB S800 I\/O system and uses the S800 mechanical configuration with ModuleBus communication.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental conditions are specified for DO814 operation?\u003cbr\u003eA: The module operates from 0 to +55 deg C and supports 5 to 95 % relative humidity without condensation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DO814 module on the ABB S800 I\/O mounting arrangement according to system hardware documentation.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC field supply polarity before connecting output loads.\u003c\/li\u003e\n\u003cli\u003eSeparate digital output wiring from high voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding methods for cabinet shielding and signal reference connections.\u003c\/li\u003e\n\u003cli\u003eConfirm connected field devices match the module output current limitation and voltage range.\u003c\/li\u003e\n\u003cli\u003eCheck ModuleBus connection integrity before system commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify output channel status indicators after completing field wiring tests.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619469488216,"sku":"DO814 3BUR001455R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO814-3BUR001455R1-3_1200x1200_6583047f-06af-44a4-8ef6-03798e5a33a7.jpg?v=1787039368"},{"product_id":"abb-s800-i-o-di840-3bse020836r1-digital-input-module","title":"ABB  S800 I\/O DI840 3BSE020836R1 Digital Input Module","description":"\u003ch2\u003eABB DI840 3BSE020836R1 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DI840 3BSE020836R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDI840\u003c\/strong\u003e Digital Input Module, provides 16 channel 24 VDC current sinking input acquisition for S800 I\/O systems with single or redundant configurations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI840 3BSE020836R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range \"0\"\u003c\/td\u003e\n\u003ctd\u003e-30 to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range \"1\"\u003c\/td\u003e\n\u003ctd\u003e11 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e3.3 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroupwise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Function\u003c\/td\u003e\n\u003ctd\u003eYes, event resolution 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Queue Capacity\u003c\/td\u003e\n\u003ctd\u003e257 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Time Range\u003c\/td\u003e\n\u003ctd\u003e0 to 127 ms selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Recording Accuracy\u003c\/td\u003e\n\u003ctd\u003e0 ms \/ +1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003eTypical 2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA at +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal 24 VDC Consumption\u003c\/td\u003e\n\u003ctd\u003e15 mA + transducer power, maximum 335 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm W x 102 mm D x 119 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Sequence of Event and Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe DI840 integrates Sequence of Event (SOE) recording for time-critical digital input monitoring. The module captures input transitions with 1 ms resolution and stores up to 257 event records in the internal event queue.\u003c\/p\u003e\n\u003cp\u003eFurthermore, each input channel contains current limiting components, EMC protection components, an optical isolation barrier, and a dedicated status LED. The transducer power supply is supervised and current limited, with one power output assigned for every two input channels.\u003c\/p\u003e\n\u003cp\u003eThe S800 I\/O architecture supports backplane bus communication and I\/O density scaling within ABB automation platforms. The module provides channel diagnostics, process power supervision, and internal circuit monitoring for system status evaluation.\u003c\/p\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DI840 operates as an S800 I\/O digital acquisition module with ABB ModuleBus communication. The module supports redundant installation concepts and maintains isolated field signal processing through optical barriers.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the module provides front LED diagnostics including Fault, Run, Warning, and channel status indication for channels 1 to 16. These indicators allow direct verification of field signal states and module operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe module supports compatibility with TU810, TU812, TU814, TU818, TU830, TU833, TU838, TU842, TU843, and TU852 Module Termination Units.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DI840 support Sequence of Event recording?\u003cbr\u003eA: Yes. The DI840 provides SOE functionality with 1 ms event resolution and stores up to 257 events in the event queue.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DI840 operate in redundant configurations?\u003cbr\u003eA: Yes. The DI840 supports redundant S800 I\/O applications and uses compatible ABB Module Termination Units for installation.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic functions are available on the DI840?\u003cbr\u003eA: The module monitors process power, internal circuitry, and channel conditions. Front LEDs provide Fault, Run, Warning, and channel status indications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DI840 module in an ABB S800 I\/O station using the specified compatible Module Termination Unit. Verify correct keying code selection before mechanical installation.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring according to ABB terminal assignment documentation. Keep digital signal cables separated from high voltage power conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure protective grounding, shielding practices, and cabinet environmental requirements comply with IEC installation standards. Confirm ModuleBus connection integrity before system commissioning.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619841929304,"sku":"DI840 3BSE020836R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI840-3BSE020836R1-3_1200x1200_9595821f-e3f0-49bb-8679-7f5991478905.jpg?v=1787046644"},{"product_id":"abb-s800-i-o-di828-3bse069054r1-digital-input-module","title":"ABB  S800 I\/O DI828 3BSE069054R1 Digital Input Module","description":"\u003ch2\u003eABB DI828 3BSE069054R1 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 120 V AC\/DC digital signal acquisition in ABB S800 I\/O systems, the \u003cstrong\u003eABB DI828 3BSE069054R1\u003c\/strong\u003e (\u003cstrong\u003eDI828\u003c\/strong\u003e Digital Input Module) provides direct electrical monitoring of discrete input states through individually isolated channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI828 3BSE069054R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 x 11 x 11.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput dependent, 8.5 mA at 120 V AC \/ 2.4 mA at 120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e120 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e77 to 130 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e75 to 130 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e14.2 kOhm AC \/ 50 kOhm DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filter Times\u003c\/td\u003e\n\u003ctd\u003e2.5 +\/- 0.5 ms, 5 +\/- 1 ms, 10 +\/- 2 ms, 20 +\/- 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Filter On\/Off Delay\u003c\/td\u003e\n\u003ctd\u003e5 ms \/ 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control I\/O Architecture Features\u003c\/h3\u003e\n\u003cp\u003eThe DI828 integrates with ABB S800 I\/O backplane communication structures for deterministic digital signal handling. It supports I\/O density scaling through 16 input channels while maintaining individual channel isolation.\u003c\/p\u003e\n\u003cp\u003eThe module uses optical isolation barriers, EMC protection components, current limiting circuits, input state LEDs, and analog filtering on each input channel. Therefore, the module separates field signal conditions from internal electronics during normal operation.\u003c\/p\u003e\n\u003cp\u003eABB S800 I\/O modules use structured backplane bus communication for controller interaction. The DI828 supports stable digital acquisition within ABB control architectures where firmware and hardware compatibility follow the configured S800 I\/O system requirements.\u003c\/p\u003e\n\u003cp\u003eThe module also supports voltage supervision functions. Channel 1 supervises the supply voltage condition for channels 2 to 8, while channel 16 supervises channels 9 to 15. When supervision detects voltage loss, the module reports channel errors through the ModuleBus interface and activates the Warning LED.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signals does the ABB DI828 3BSE069054R1 process?\u003cbr\u003eA: The DI828 processes 120 V AC\/DC discrete input signals with 16 individually isolated channels. It accepts 77 to 130 V AC and 75 to 130 V DC field inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DI828 provide electrical isolation between input channels?\u003cbr\u003eA: Yes. Each input channel contains an optical isolation barrier and independent protection components to separate field signals.\u003c\/p\u003e\n\u003cp\u003eQ: How does voltage supervision operate on the DI828 module?\u003cbr\u003eA: Channel 1 supervises channels 2 to 8, and channel 16 supervises channels 9 to 15. If the monitored voltage disappears, the module generates channel error information through the ModuleBus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DI828 module according to ABB S800 I\/O installation requirements and verify the ModuleBus connection before applying field voltage.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring with correct polarity and maintain separation between signal wiring and high-energy power conductors. Use appropriate grounding methods for cable shields where required by the control system design.\u003c\/p\u003e\n\u003cp\u003eConfirm that the connected AC\/DC voltage levels remain within the specified input ranges before commissioning. Check input LEDs and ModuleBus diagnostics to validate channel operation after installation.\u003c\/p\u003e\n\u003cp\u003eAvoid routing input cables near sources of electromagnetic interference. Verify terminal connections, insulation conditions, and cabinet ventilation before placing the module into continuous service.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619846451288,"sku":"DI828 3BSE069054R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI8283BSE069054R1-3.jpg?v=1787046697"},{"product_id":"abb-s800-i-o-di825-3bse036373r1-digital-input-module","title":"ABB  S800 I\/O DI825 3BSE036373R1 Digital Input Module","description":"\u003ch2\u003eABB DI825 3BSE036373R1 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DI825 3BSE036373R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDI825\u003c\/strong\u003e Digital Input Module, provides 125 VDC current sinking signal acquisition for S800 I\/O ModuleBus platforms. It processes isolated field input signals through eight channels with selectable digital filtering, event recording, and process voltage supervision functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI825 3BSE036373R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Function\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm W x 119 mm H x 102 mm D; 111 mm D including connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 4.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range State 0\u003c\/td\u003e\n\u003ctd\u003e0 to 20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range State 1\u003c\/td\u003e\n\u003ctd\u003e71 to 156 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e41.5 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filter Time\u003c\/td\u003e\n\u003ctd\u003e0 to 100 ms selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Recording Accuracy\u003c\/td\u003e\n\u003ctd\u003e-0.25 ms to 1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Recording Resolution\u003c\/td\u003e\n\u003ctd\u003e0.4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2300 VAC Channel to Ground, 1350 VAC Channel to Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 90 mA at +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 VDC Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O ModuleBus Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe DI825 uses S800 I\/O backplane communication for digital process signal transfer and diagnostic reporting. The module provides eight isolated input channels, where each channel includes current limiting components, EMC protection circuits, input status LED indication, and optical isolation barriers.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module supports Sequence of Event (SOE) recording with millisecond-level event capture performance. Channel 1 can supervise the process voltage for channels 2 to 4, while channel 8 can supervise the process voltage for channels 5 to 7. When supervised voltage disappears, the module generates channel error information and activates the warning indication.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DI825 support redundant operation in an S800 I\/O configuration?\u003cbr\u003eA: No. The DI825 is specified as a non-redundant digital input module. It communicates through the S800 I\/O ModuleBus interface without redundant channel operation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module detect loss of field supply voltage?\u003cbr\u003eA: Channel 1 and channel 8 can operate as voltage supervision inputs for grouped channels. If the monitored process voltage disappears, the module reports a channel error and warning status through ModuleBus diagnostics.\u003c\/p\u003e\n\u003cp\u003eQ: What MTU types are compatible with the DI825?\u003cbr\u003eA: The DI825 supports TU811, TU813, TU831, TU839, and TU851 Module Termination Units with keying code AB.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DI825 in an ABB S800 I\/O station using the specified compatible MTU type. Verify the keying code before mounting the module to prevent incorrect hardware installation.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring according to the channel assignment and voltage polarity requirements. Maintain separation between digital input wiring and high-energy power cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding methods for cable shields according to site electrical standards. Confirm that the field supply voltage remains within the specified input range before commissioning.\u003c\/p\u003e\n\u003cp\u003eCheck front LED indications after installation. Verify Run, Fault, Warning, and channel status indicators during functional testing.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619851989080,"sku":"DI825 3BSE036373R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI825-3BSE036373R1-3_1200x1200_77e28592-7a29-4bcc-8e17-e405de5edafb.jpg?v=1787046792"},{"product_id":"abb-s800-i-o-di821-3bse008550r1-s800-digital-input-module","title":"ABB S800 I\/O DI821 3BSE008550R1 S800 Digital Input Module","description":"\u003ch2\u003eABB DI821 3BSE008550R1 S800 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DI821 3BSE008550R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDI821\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for 230 V AC\/DC discrete signal acquisition within the ABB S800 I\/O system. It provides 8 individually isolated input channels with voltage supervision functions, optical isolation barriers, EMC protection, and configurable input filtering.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI821 3BSE008550R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm W x 102 mm D x 119 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 2.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e164 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e175 to 275 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e11 mA at 230 V AC; 1.6 mA at 220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e21 kOhm AC \/ 134 kOhm DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filter Time\u003c\/td\u003e\n\u003ctd\u003e2, 4, 8, 16 ms selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Filter Delay\u003c\/td\u003e\n\u003ctd\u003e5 \/ 28 ms On\/Off delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 V ModuleBus: 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 V ModuleBus Consumption\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 V External Consumption\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Function\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible MTU\u003c\/td\u003e\n\u003ctd\u003eTU811, TU813, TU831, TU839, TU851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4 and EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Industrial Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe ABB DI821 integrates with the S800 I\/O architecture through ModuleBus communication and supports high-voltage discrete signal monitoring. Each input channel includes current limiting components, EMC protection components, LED status indication, optical isolation, and a 6 ms analog filter.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module provides process voltage supervision through dedicated channel monitoring. Channel 1 supervises channels 2 to 4, while channel 8 supervises channels 5 to 7. When the monitored supply voltage disappears, the module activates the corresponding error input and Warning LED indication. The diagnostic information is transferred through the ModuleBus interface.\u003c\/p\u003e\n\u003cp\u003eThe DI821 supports ABB industrial control installations requiring dense digital I\/O scaling, S800 backplane communication, and firmware-compatible module integration. Its isolated channel design separates field voltage signals from internal electronics to maintain electrical separation between process circuits and control hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the DI821 provide electrical isolation between input channels?\u003cbr\u003eA: The DI821 uses individually isolated input channels. Each channel contains an optical isolation barrier together with EMC protection and current limiting components.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DI821 monitor loss of field supply voltage?\u003cbr\u003eA: Yes. Channel 1 and Channel 8 can operate as voltage supervision inputs for separate channel groups. The module reports supervision errors through the ModuleBus interface.\u003c\/p\u003e\n\u003cp\u003eQ: What MTU units are compatible with the DI821 module?\u003cbr\u003eA: The DI821 supports TU811, TU813, TU831, TU839, and TU851 MTU configurations with AC keying code.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DI821 module only in compatible ABB S800 I\/O assemblies with the correct AC keying configuration. Verify that the selected MTU matches the module specification before wiring field circuits.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring according to ABB installation documentation. Maintain separation between high-voltage AC\/DC signal wiring and low-level communication or instrumentation wiring to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding methods for cabinet assemblies and ensure cable shields follow the site grounding practice. Confirm input polarity, voltage level, and channel assignment before energizing the module.\u003c\/p\u003e\n\u003cp\u003eCheck front LED indicators after installation. Verify Run, Fault, Warning, and channel status indications through the controller diagnostic interface before placing the I\/O point into service.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619857231960,"sku":"DI821 3BSE008550R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI821-3BSE008550R1-3_1200x1200_940d0ad5-7891-488e-96ce-fce57f0af10b.jpg?v=1787046883"},{"product_id":"abb-s800-i-o-di818-3bse069052r1-digital-input-module","title":"ABB S800 I\/O DI818 3BSE069052R1 Digital Input Module","description":"\u003ch2\u003eABB DI818 3BSE069052R1 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC digital signal acquisition in the ABB S800 I\/O system, the \u003cstrong\u003eABB DI818 3BSE069052R1\u003c\/strong\u003e (\u003cstrong\u003eDI818\u003c\/strong\u003e Digital Input Module) provides direct electrical input processing through 32 isolated channels for industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI818 3BSE069052R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003eIsolated in two groups of 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Type\u003c\/td\u003e\n\u003ctd\u003eDI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Termination Unit Compatibility\u003c\/td\u003e\n\u003ctd\u003eTU818, TU819, TU830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm depth x 119 mm height x 45 mm width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Classification\u003c\/td\u003e\n\u003ctd\u003eI-O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eCategory 5 Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Backplane and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DI818 integrates with the ABB S800 I\/O architecture through the module backplane communication interface. Therefore, the module supports high-density digital input deployment with 32 channels arranged into two electrically isolated groups of 16 channels.\u003c\/p\u003e\n\u003cp\u003eThe isolated channel grouping reduces signal interaction between field circuits and the control system. Additionally, the module termination units TU818, TU819, and TU830 provide the required field wiring interface for cabinet installation and signal distribution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are the DI818 input channels electrically organized?\u003cbr\u003eA: The DI818 contains 32 digital input channels divided into two isolated groups of 16 channels. Each group operates as an independent field signal section.\u003c\/p\u003e\n\u003cp\u003eQ: Which termination units support the DI818 module?\u003cbr\u003eA: The DI818 is designed for use with ABB TU818, TU819, and TU830 Module Termination Units for field connection.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DI818 be installed in systems requiring channel isolation?\u003cbr\u003eA: Yes. The module provides electrical isolation between the two groups of 16 input channels, supporting separated field signal wiring configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DI818 module on the compatible ABB S800 I\/O carrier according to ABB system installation procedures.\u003c\/li\u003e\n\u003cli\u003eVerify that the selected Module Termination Unit matches the field wiring requirements before connection.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level signal cables from high-voltage power wiring to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shields according to the cabinet grounding design and local electrical standards.\u003c\/li\u003e\n\u003cli\u003eConfirm the 24 VDC input wiring polarity before applying field power.\u003c\/li\u003e\n\u003cli\u003eCheck module status indicators after installation to verify correct communication and input operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619865423960,"sku":"DI818 3BSE069052R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI818-3BSE069052R1-3_1200x1200_4c741be6-1611-4eb6-b8b4-81dfd7cb7e75.jpg?v=1787047042"},{"product_id":"di811-3bse008552r1-abb-s800-i-o-digital-input-module","title":"DI811 3BSE008552R1 ABB S800 I\/O Digital Input Module","description":"\u003ch2\u003eABB DI825 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DI825 3BSE008552R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDI825\u003c\/strong\u003e Digital Input Module, provides 48 VDC discrete signal acquisition for S800 I\/O systems through isolated input channels and ModuleBus diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI825 3BSE008552R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm W x 102 mm D x 119 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range \"0\"\u003c\/td\u003e\n\u003ctd\u003e-60 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range \"1\"\u003c\/td\u003e\n\u003ctd\u003e30 to 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4 mA at 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e11 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eTwo isolated groups with 8 channels each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Times\u003c\/td\u003e\n\u003ctd\u003e2 ms, 4 ms, 8 ms, 16 ms selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +5 V\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +24 V\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 V Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Function\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity Function\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTU Compatibility\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU818, TU830, TU833, TU838, TU850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4 and EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Backplane and I\/O Density Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe DI825 operates within the ABB S800 I\/O platform and communicates through the ModuleBus interface. The module uses ABB backplane bus communication architecture to transfer diagnostic states and input data between field channels and the controller system.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module structure supports I\/O density scaling by providing 16 digital input channels in a compact S800 form factor. Each input channel includes current limiting components, EMC protection components, LED status indication, and an optical isolation barrier.\u003c\/p\u003e\n\u003cp\u003eThe input channels are arranged into two electrically isolated groups. Each group contains eight channels and one process voltage supervision input. Therefore, the module can detect loss of field supply voltage and report channel-related error conditions through the ModuleBus diagnostic system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the DI825 handle input channel isolation?\u003cbr\u003eA: The DI825 uses two individually isolated input groups, with eight channels in each group. Each input channel includes an optical isolation barrier and EMC protection components.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic information is available through ModuleBus?\u003cbr\u003eA: The module provides module error, module warning, and channel error status. Process voltage supervision signals are transferred through the ModuleBus interface.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DI825 operate with redundant configurations?\u003cbr\u003eA: No. The DI825 is specified as a non-redundant digital input module for S800 I\/O applications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DI825 module using a compatible ABB S800 MTU according to the selected terminal configuration. Verify that the TU810, TU812, TU814, TU818, TU830, TU833, TU838, or TU850 MTU matches the module keying code before installation.\u003c\/p\u003e\n\u003cp\u003eRoute field signal cables separately from high-voltage power conductors to reduce electromagnetic interference. Connect cable shielding according to the site grounding practice and applicable EMC installation requirements.\u003c\/p\u003e\n\u003cp\u003eConfirm the 48 VDC field supply polarity before energizing the input circuits. Check the front LED indicators after startup to verify module operation, channel states, and process voltage supervision status.\u003c\/p\u003e\n\u003cp\u003eAvoid exceeding the specified field cable length and environmental limits. Maintain enclosure protection requirements to preserve the IP20 installation rating.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619871649880,"sku":"DI811 3BSE008552R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI811-3BSE008552R1-3_1200x1200_58cff687-3dba-45f2-9f46-614792e822c4.jpg?v=1787047137"},{"product_id":"di810-ea-3bse008508r2-abb-s800-i-o-digital-input-module","title":"DI810-EA 3BSE008508R2 ABB S800 I\/O Digital Input Module","description":"\u003ch2\u003eABB DI810 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DI810 3BSE008508R2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDI810\u003c\/strong\u003e Digital Input Module, provides direct electrical signal acquisition for digital field devices within ABB S800 I\/O system platforms. The module receives 24 VDC process signals and transfers channel status data to the controller through the I\/O communication interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI810 3BSE008508R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 digital input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003eTyp. 6 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated input design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Indication\u003c\/td\u003e\n\u003ctd\u003eIndividual channel LED status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting with S800 I\/O infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eModule and channel status monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial I\/O Backplane and Communication Integration\u003c\/h3\u003e\n\u003cp\u003eThe DI810 operates as an ABB S800 I\/O digital acquisition module and exchanges channel information through the system backplane communication interface. The module supports I\/O density scaling by providing multiple discrete input channels within a compact hardware format.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module architecture includes electrical isolation between field input circuits and internal logic circuits. This design separates process wiring from controller electronics and supports stable digital signal handling in industrial control installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many digital input channels does the ABB DI810 provide?\u003cbr\u003eA: The DI810 provides 16 digital input channels for 24 VDC field signal acquisition.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DI810 provide electrical isolation between field signals and internal electronics?\u003cbr\u003eA: Yes. The module uses an isolated input design to separate field signal circuits from internal module logic.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field signals can connect to the DI810?\u003cbr\u003eA: The module accepts standard 24 VDC digital signals from industrial field devices such as switches, sensors, and status contacts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DI810 module on the designated ABB S800 I\/O mounting structure according to system hardware documentation.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring polarity matches the digital input terminal configuration before applying operating voltage.\u003c\/li\u003e\n\u003cli\u003eRoute digital signal cables separately from high-voltage power cables and high-frequency switching conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding standard and avoid multiple grounding points that may introduce signal noise.\u003c\/li\u003e\n\u003cli\u003eConfirm LED channel indications after installation to verify correct field device switching status.\u003c\/li\u003e\n\u003cli\u003eCheck controller configuration parameters before placing the module into active process operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619879546968,"sku":"DI810-EA 3BSE008508R2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI810-EA-3BSE008508R2-3_1200x1200_86c53261-1d8f-44bc-b6a7-fb27054d8a9f.jpg?v=1787047233"},{"product_id":"di802-3bse022360r1-abb-s800-i-o-digital-input-module","title":"DI802 3BSE022360R1 ABB S800 I\/O Digital Input Module","description":"\u003ch2\u003eABB DI802 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DI802\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDI802\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for 120 V AC\/DC discrete signal acquisition within the ABB S800 I\/O system. The module provides 8 individually isolated digital input channels with current sinking signal processing, optical isolation, EMC protection, and configurable digital filtering for industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDI802 3BSE022360R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e120 V AC, 110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range Logic \"0\"\u003c\/td\u003e\n\u003ctd\u003e0 to 30 V AC, 0 to 20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range Logic \"1\"\u003c\/td\u003e\n\u003ctd\u003e77 to 130 V AC, 75 to 145 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e10 mA at 120 V AC, 2.8 mA at 110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e12 kOhm AC, 39 kOhm DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Times\u003c\/td\u003e\n\u003ctd\u003e2 ms, 4 ms, 8 ms, 16 ms selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e200 m for AC, 600 m for DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003eTypical 2.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +5 V Modulebus\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V Modulebus\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V External\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 86.1 x 58.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 2.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe ABB DI802 integrates with the S800 I\/O backplane architecture to transfer digital input status data to the controller. The module processes field voltage signals through current limiting components, EMC protection circuits, input status LEDs, and optical isolation barriers.\u003c\/p\u003e\n\u003cp\u003eFurthermore, each input channel operates independently to maintain channel separation. The module supports selectable digital filtering times of 2 ms, 4 ms, 8 ms, and 16 ms, allowing signal conditioning according to field device switching characteristics.\u003c\/p\u003e\n\u003cp\u003eThe input design supports industrial AC and DC discrete signals while maintaining electrical isolation between field wiring and the S800 I\/O communication interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB DI802 support redundant operation or high integrity configurations?\u003cbr\u003eA: No. The DI802 does not support redundancy, high integrity functions, or SIL-related configurations. It operates as a standard S800 I\/O digital input module.\u003c\/p\u003e\n\u003cp\u003eQ: How does the DI802 isolate field input signals?\u003cbr\u003eA: Each input channel uses optical isolation with EMC protection and current limiting components to separate field signals from internal electronics.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic functions are available on the DI802?\u003cbr\u003eA: The module provides status indication through front LEDs and supports process voltage supervision on channel 8 with module error, module warning, and channel error indications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the ABB DI802 on the designated S800 I\/O mounting arrangement and verify correct module addressing before system commissioning.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring according to the approved terminal assignment. Maintain separation between AC field signal cables and sensitive communication wiring to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eUse shielded cables where required by the installation environment and connect shields according to the plant grounding standard. Verify conductor size, terminal torque, and insulation condition before energizing the module.\u003c\/p\u003e\n\u003cp\u003eConfirm that the field voltage matches the specified input range of 77 to 130 V AC or 75 to 145 V DC before operation. Check LED status after power-up to validate channel state and module diagnostics.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619886395480,"sku":"DI802 3BSE022360R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DI8023BSE022360R1-3.jpg?v=1787047319"},{"product_id":"ci873k01-3bse056899r1-abb-s800-i-o-ethernet-ip-interface","title":"CI873K01 3BSE056899R1 ABB S800 I\/O Ethernet\/IP Interface","description":"\u003ch2\u003eABB CI873K01 Ethernet\/IP Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for Ethernet\/IP communication interface execution in ABB System 800xA control platforms, the \u003cstrong\u003eABB 3BSE056899R1\u003c\/strong\u003e (\u003cstrong\u003eCI873K01\u003c\/strong\u003e Communication Module) provides direct physical network connectivity through the CI873 communication interface with TP867 baseplate integration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI873K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE056899R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet\/IP Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Components\u003c\/td\u003e\n\u003ctd\u003eCI873 Communication Interface, TP867 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB System 800xA \/ AC 800M communication architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127.5 mm depth x 186 mm height x 59 mm width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Ethernet\/IP Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe CI873K01 provides Ethernet\/IP interface capability for ABB control system communication networks. Therefore, the module handles industrial Ethernet data exchange between connected devices and the controller environment through the configured communication interface.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module supports ABB industrial control architectures where deterministic Profinet \/ EtherNet\/IP network structures require defined communication paths. The CI873 communication interface uses the TP867 baseplate for mechanical installation and system integration.\u003c\/p\u003e\n\u003cp\u003eThe module belongs to ABB PLC\/DCS communication hardware, where backplane bus communication and firmware compatibility determine the connection between communication modules and controller systems. Configuration parameters must match the installed ABB control system firmware and engineering environment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What components are included with the CI873K01 package?\u003cbr\u003eA: The CI873K01 package includes the CI873 Communication Interface and TP867 Baseplate according to the supplied product specification.\u003c\/p\u003e\n\u003cp\u003eQ: What communication function does the CI873K01 provide?\u003cbr\u003eA: The CI873K01 provides an Ethernet\/IP interface function for ABB control system communication networks.\u003c\/p\u003e\n\u003cp\u003eQ: Does the provided specification define operating temperature and power consumption values?\u003cbr\u003eA: No. The supplied technical data does not specify operating temperature limits or power consumption values.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the CI873K01 on the designated ABB mounting arrangement with the TP867 baseplate correctly secured before electrical connection.\u003c\/p\u003e\n\u003cp\u003eVerify that Ethernet\/IP network wiring follows industrial installation practices. Maintain proper cable separation from high-voltage power conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConnect protective grounding according to the control cabinet grounding design. Confirm shielding continuity for communication cables where required by the system installation standard.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, check module seating, connector engagement, network addressing, and controller configuration compatibility.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619890458712,"sku":"CI873K01 3BSE056899R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI873K01-3BSE056899R1-2_1200x1200_27710918-aed1-492f-a678-71234bcd57a5.jpg?v=1787047453"},{"product_id":"ci873ak01-3bse092695r1-abb-ac-800m-communication-interface-module","title":"CI873AK01 3BSE092695R1 ABB AC 800M Communication Interface Module","description":"\u003ch2\u003eABB CI873AK01 Communication Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for Ethernet communication interface execution in ABB System 800xA and AC 800M controller environments, the \u003cstrong\u003eABB CI873AK01\u003c\/strong\u003e (\u003cstrong\u003eCI873AK01\u003c\/strong\u003e Communication Interface Module) provides direct physical network connectivity and data exchange functions. The module is cataloged under order code \u003cstrong\u003e3BSE092695R1\u003c\/strong\u003e and supports communication tasks between controller hardware and external industrial networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI873AK01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE092695R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB System 800xA \/ AC 800M controller environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eIndustrial network communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eController system hardware mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Configuration\u003c\/td\u003e\n\u003ctd\u003eCommunication interface package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Communication Interface Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CI873AK01 operates as a communication interface component within ABB controller platforms. It manages data transfer between AC 800M control hardware and connected communication networks. Therefore, the module handles network interface processing while maintaining compatibility with ABB engineering and control system structures.\u003c\/p\u003e\n\u003cp\u003eThe module follows ABB industrial control architecture principles, including backplane communication handling, controller integration, and system-level data exchange. Additionally, CI873AK01 configurations support scalable communication structures where multiple automation devices exchange process and diagnostic information.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the ABB CI873AK01 module?\u003cbr\u003eA: The CI873AK01 functions as a communication interface module that provides network communication capability for ABB System 800xA and AC 800M controller environments.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CI873AK01 be installed as an independent controller unit?\u003cbr\u003eA: No. The CI873AK01 operates as a dedicated communication hardware component and requires integration with compatible ABB controller system hardware.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CI873AK01 require firmware compatibility checks during replacement?\u003cbr\u003eA: Yes. Firmware and system configuration compatibility should be verified before replacement to ensure correct communication operation within the controller platform.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the CI873AK01 according to ABB system installation procedures and approved cabinet design practices.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify controller compatibility and hardware configuration before installation.\u003c\/li\u003e\n\u003cli\u003eMount the module in the designated ABB controller system position.\u003c\/li\u003e\n\u003cli\u003eKeep communication cables separated from high-voltage power wiring to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the cabinet grounding design and industrial EMC practices.\u003c\/li\u003e\n\u003cli\u003eConfirm module status indicators after power-up and validate communication diagnostics through the engineering tool.\u003c\/li\u003e\n\u003cli\u003ePerform firmware and configuration verification before placing the system into operational service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619894980696,"sku":"CI873AK01 3BSE092695R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI873AK013BSE092695R1-3.jpg?v=1787047509"},{"product_id":"ci871k01-3bse092693r1-abb-800xa-profinet-io-interface","title":"CI871K01 3BSE092693R1 ABB 800xA PROFINET IO Interface","description":"\u003ch2\u003eABB CI871AK01 PROFINET IO Interface\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE092693R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI871AK01\u003c\/strong\u003e PROFINET IO Interface, provides PROFINET IO communication within ABB 800xA control architectures. The package includes the CI871A communication interface and TP867 baseplate.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI871AK01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE092693R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eCI871A Communication Interface; TP867 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eABB 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e800xA Compatibility\u003c\/td\u003e\n\u003ctd\u003e6.0.3.3, 6.1.1, and onwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact Control Builder Compatibility\u003c\/td\u003e\n\u003ctd\u003e6.0.0-3, 6.1.1, and onwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127.5 mm D x 59 mm W x 186 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Quantity\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePROFINET IO Communication and Industrial Network Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CI871AK01 provides a PROFINET IO interface for data exchange between ABB control-system infrastructure and compatible PROFINET IO devices. It operates as a communication interface rather than a standalone controller.\u003c\/p\u003e\n\u003cp\u003eThe supplied package combines the \u003cstrong\u003eCI871A\u003c\/strong\u003e communication interface with the \u003cstrong\u003eTP867\u003c\/strong\u003e baseplate. Therefore, installation requires the associated mounting and backplane arrangement supported by the target ABB architecture.\u003c\/p\u003e\n\u003cp\u003eFor system integration, verify the installed 800xA and Compact Control Builder versions before commissioning. The supplied ABB data specifically identifies compatibility with 800xA 6.0.3.3 and 6.1.1, Compact Control Builder 6.0.0-3 and 6.1.1, and later supported versions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocol does the CI871AK01 support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CI871AK01 is a PROFINET IO communication interface for ABB control-system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is included with ABB 3BSE092693R1?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The package includes one CI871A communication interface and one TP867 baseplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which ABB software versions are identified as compatible?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data specifies ABB 800xA 6.0.3.3 and 6.1.1, Compact Control Builder 6.0.0-3 and 6.1.1, and onwards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the CI871A and TP867 assembly according to the applicable ABB hardware installation documentation. Confirm the mounting position and backplane connection before energizing the system.\u003c\/p\u003e\n\u003cp\u003eRoute PROFINET network cabling separately from high-voltage power conductors and high-noise switching circuits where practical. Maintain proper cable shielding and grounding according to the installed network architecture.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify the module identity, hardware revision, software compatibility, network addressing, and PROFINET device configuration. Do not apply operating parameters that are not supported by the system documentation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623529836632,"sku":"CI871K01 3BSE092693R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI871K013BSE092693R1-3.jpg?v=1787126373"},{"product_id":"ci871k01-3bse056767r1-abb-profinet-io-interface","title":"CI871K01 3BSE056767R1 ABB Profinet IO Interface","description":"\u003ch2\u003eABB CI871K01 Profinet IO Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for Profinet I\/O communication, the \u003cstrong\u003eABB CI871K01\u003c\/strong\u003e (\u003cstrong\u003eCI871\u003c\/strong\u003e Profinet I\/O Interface) provides network communication between ABB control hardware and Profinet I\/O devices. The package includes the CI871 communication interface and TP867 baseplate.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI871K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCI871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE056767R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eProfinet IO Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eCI871 Communication Interface + TP867 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eProfinet IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127.5 mm D x 186 mm H x 59 mm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eComplies with EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003eCategory 5 - Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e851762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet IO Communication and Hardware Integration\u003c\/h3\u003e\n\u003cp\u003eThe CI871 provides the communication interface required for Profinet IO connectivity. It operates as a dedicated network component rather than as a field signal termination device.\u003c\/p\u003e\n\u003cp\u003eThe supplied TP867 baseplate provides the specified mechanical mounting interface for the CI871. Therefore, installation should maintain the manufacturer's prescribed baseplate arrangement and physical clearances.\u003c\/p\u003e\n\u003cp\u003eFor network operation, Profinet cabling should follow the applicable industrial Ethernet wiring practices. Keep communication cables separated from high-voltage or high-current conductors where practical, and maintain appropriate shielding and grounding practices.\u003c\/p\u003e\n\u003cp\u003eThe supplied data does not specify communication speed, supported Profinet device count, network topology limits, firmware compatibility, or backplane current consumption. These parameters should therefore be verified against the applicable ABB system documentation before system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is included with the ABB CI871K01 package?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The package includes one CI871 Communication Interface and one TP867 Baseplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What network function does the CI871K01 provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It provides a Profinet IO communication interface for connecting compatible industrial control hardware with Profinet IO devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the physical dimensions and weight of the package hardware?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied product data specifies 127.5 mm depth, 186 mm height, 59 mm width, and 0.7 kg net weight.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CI871 on the specified TP867 baseplate and secure the assembly according to ABB mechanical installation requirements.\u003c\/li\u003e\n\u003cli\u003eVerify the mounting position before connecting network or system wiring.\u003c\/li\u003e\n\u003cli\u003eRoute Profinet communication cables separately from power conductors where practical to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain cable bend radius and connector access required by the selected industrial Ethernet cabling system.\u003c\/li\u003e\n\u003cli\u003eApply the applicable shield termination and protective grounding method defined by the system installation design.\u003c\/li\u003e\n\u003cli\u003eConfirm connector engagement before commissioning network communication.\u003c\/li\u003e\n\u003cli\u003eVerify the installed module identification against the configured CI871 hardware before system startup.\u003c\/li\u003e\n\u003cli\u003eDo not assume operating temperature, power consumption, network capacity, or firmware compatibility from the supplied product identification alone; verify these values against the applicable ABB documentation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623538618456,"sku":"CI871K01 3BSE056767R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI871K01-3BSE056767R1-3_1200x1200_d69b188d-cf52-4272-b373-c3d2ac919831.jpg?v=1787126492"},{"product_id":"abb-ac-800m-ci871ak01-profinet-io-communication-interface","title":"ABB AC 800M CI871AK01 PROFINET IO Communication Interface","description":"\u003ch2\u003eABB CI871AK01 PROFINET IO Communication Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for PROFINET IO communication in System 800xA, the \u003cstrong\u003eABB CI871AK01\u003c\/strong\u003e (\u003cstrong\u003eCI871A\u003c\/strong\u003e PROFINET IO Communication Interface) connects AC 800M controllers to PROFINET IO devices through Ethernet. The module uses the CH1 Ethernet connector on the TP867 Baseplate for the PROFINET IO network. ABB specifies compatibility with System 800xA 6.0.3.3, 6.1.1, and subsequent versions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI871AK01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCI871A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE092693R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster or Slave\u003c\/td\u003e\n\u003ctd\u003eMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed Together with HI Controller\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEX-Bus Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 12 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRJ-45 female, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Connection\u003c\/td\u003e\n\u003ctd\u003eTP867 CH1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connection\u003c\/td\u003e\n\u003ctd\u003eEthernet switch required for PROFINET IO network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m according to IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2 according to IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 according to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN60529, IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eUL 60079-15, cULus Class 1, Zone 2, AEx nA IIC T4, ExnA IIC T4Gc X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd\u003eDNV-GL; ABS, BV, and LR pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Including Base\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V supply, typ. 160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePROFINET IO and CEX-Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe CI871A provides the communication path between an AC 800M controller and PROFINET IO devices. The TP867 Baseplate provides two RJ-45 Ethernet connectors; however, only CH1, which supports 100 Mbit\/s operation, is used for the PROFINET IO connection.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet cable connects the CH1 interface to the PROFINET IO network through an Ethernet switch. Therefore, the installation must place the required switch between the CI871A interface and the connected PROFINET IO network.\u003c\/p\u003e\n\u003cp\u003eInternally, the CI871 expansion unit contains CEX-Bus logic, a communication unit, and a DC\/DC converter. The converter derives the required operating voltage from the +24 V supply through the CEX-Bus. The CEX-Bus supports a maximum of 12 units.\u003c\/p\u003e\n\u003cp\u003eThe module supports module redundancy but does not provide line redundancy. It also supports hot swap according to the stated hardware configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Ethernet connector on the TP867 Baseplate carries the PROFINET IO connection?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CH1 RJ-45 connector is used for the PROFINET IO connection. The installation connects CH1 to the PROFINET IO network through an Ethernet switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What System 800xA versions support the CI871AK01?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CI871A operates with System 800xA 6.0.3.3, 6.1.1, and subsequent versions. Earlier compatibility should not be assumed without ABB documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the typical 24 V supply consumption?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified typical consumption is 160 mA from the 24 V supply through the CEX-Bus arrangement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the CI871A with its TP867 Baseplate according to the AC 800M hardware installation procedure.\u003c\/li\u003e\n\u003cli\u003eConnect the required 24 V supply and verify the CEX-Bus installation before commissioning.\u003c\/li\u003e\n\u003cli\u003eConnect the PROFINET IO Ethernet cable to the CH1 RJ-45 connector.\u003c\/li\u003e\n\u003cli\u003eRoute the Ethernet cable to the PROFINET IO network through the required Ethernet switch.\u003c\/li\u003e\n\u003cli\u003eKeep Ethernet communication wiring separated from high-voltage and high-current power conductors where practical.\u003c\/li\u003e\n\u003cli\u003eApply appropriate cable shielding and grounding practices for the installed industrial Ethernet network.\u003c\/li\u003e\n\u003cli\u003eVerify that the installation environment remains within 0 to +55 deg C operating temperature and 5 to 95 % non-condensing humidity.\u003c\/li\u003e\n\u003cli\u003eConfirm that the selected System 800xA software version is 6.0.3.3, 6.1.1, or a subsequent supported version before commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck the RJ-45 connection and network topology before enabling PROFINET IO device communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623545860184,"sku":"CI871A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI871A-3.jpg?v=1787126615"}],"url":"https:\/\/www.industriaxplc.com\/id\/collections\/system-800xa-s800-ac800m.oembed?page=6","provider":"IndustriaX Limited","version":"1.0","type":"link"}