{"title":"PLC Systems \u0026 Modules","description":"\u003cp\u003ePLC systems and modules deliver flexible automation for industries worldwide. Our inventory includes controllers, input\/output modules, and communication units from Allen-Bradley, Siemens, GE, and other leading brands.\u003c\/p\u003e","products":[{"product_id":"5466-258-woodward-discrete-i-o-module","title":"5466-258 | Woodward Discrete I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eWoodward 5466-258\u003c\/strong\u003e Discrete I\/O Module is engineered for integration into MicroNet Digital Control systems. It connects directly to the motherboard via card guides and secures with dual front-panel screws. Two ergonomic handles allow safe disengagement from the chassis without damaging connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module supports real-time node replacement, minimizing system downtime. It mounts on a DIN rail and accepts discrete inputs powered by either internal or external 24 Vdc sources.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSet the module address using rotary switches before mounting. Ensure network cables remain connected during node replacement. To replace a faulty node, remove terminal blocks and the module, match address settings on the new unit, and reinsert. Reset the node via the application program to resume communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5466-258\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMicroNet Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Current\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 cm × 16 cm × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Configuration\u003c\/td\u003e\n\u003ctd\u003eRotary switches (x2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Replacement\u003c\/td\u003e\n\u003ctd\u003eReal-time, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eApplication \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eWoodward 5466-258\u003c\/strong\u003e module is ideal for industrial automation systems requiring discrete input handling. It supports fault-tolerant architectures and is compatible with MicroNet chassis configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts hot-swappable design and addressable node setup make it suitable for mission-critical environments such as energy plants, manufacturing lines, and process control systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161013649496,"sku":"5466-258","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5466-258-ip30pylbjjk.png?v=1756197202"},{"product_id":"woodward-5464-843-netcon-cpu-module","title":"woodward 5464-843 NetCon CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cstrong\u003e \u003c\/strong\u003eWoodward \u003cstrong\u003e5464-843\u003c\/strong\u003e NetCon CPU Module is a powerful processing unit designed for the MicroNet™ and Vertex-Pro Motor-Driven Compressor Control Systems. Featuring a Motorola MPC5200 processor, 128 MB DDR RAM, and 64 MB flash memory, this module delivers fast, deterministic control for complex industrial applications.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMotor-driven compressor control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMicroNet™ and NetCon® digital control platforms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems (DCS)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-time industrial automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundant system architectures requiring VMEbus coordination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5464-843\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eMicroNet Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e16 cm × 16 cm × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eMotorola MPC5200 (40 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM \/ Flash\u003c\/td\u003e\n\u003ctd\u003e128 MB DDR \/ 64 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e2 Ethernet, 2 Real-Time Network, 2 CAN, RS232, Service Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Support\u003c\/td\u003e\n\u003ctd\u003eVideo, Keyboard, Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Standard\u003c\/td\u003e\n\u003ctd\u003eVMEbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture Support\u003c\/td\u003e\n\u003ctd\u003eSimplex \/ TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"woodward","offers":[{"title":"Default Title","offer_id":43161013715032,"sku":"5464-843","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/woodward-5464-843-b2apowgvu5z.png?v=1756197204"},{"product_id":"woodward-9905-972-linknet-6-channel-analog-output-module","title":"Woodward 9905-972 LINKnet 6-Channel Analog Output Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eWoodward 9905-972\u003c\/strong\u003e is a high-performance analog output module from the LINKnet series, designed to deliver six independent 4–20 mA outputs for industrial automation and control applications. Manufactured by Woodward Inc., this module ensures reliable signal transmission and system integrity through integrated watchdog monitoring and real-time feedback.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSix independent 4–20 mA analog outputs for flexible control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput current monitored via onboard A\/D converter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWatchdog disables drivers after 1.2 seconds of communication loss\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-replacement capability for minimal downtime\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRotary address switches for easy configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail mounting for streamlined installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eLINKnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e18–32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.0 W at 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0–25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e330 mm × 80 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014009944,"sku":"9905-972","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-9905-972-cw4axkep3f1.png?v=1756197213"},{"product_id":"woodward-5503-335-micronet-5200-cpu-module","title":"Woodward 5503-335 MicroNet 5200 CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Woodward \u003cstrong\u003e5503-335 \u003c\/strong\u003eMicroNet 5200 CPU Module is a compact, high-performance embedded controller designed for gas turbine control systems and industrial automation environments. Built around the Intel Atom processor, this module delivers a powerful balance of performance and energy efficiency, making it ideal for real-time control and monitoring applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 5503-335\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: MicroNet 5200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e: Intel Atom – optimized for industrial performance and low power consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e: Up to 4GB DDR3 – supports complex computational loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Interfaces\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple serial ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEthernet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUSB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating System Support\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWindows Embedded Standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWindows Embedded Compact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinux\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Protocols\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModbus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCANbus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePROFIBUS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesign Attributes\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact form factor for easy integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRugged connectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShock and vibration resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide operating temperature range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication Scope\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGas turbine control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-time sensor and actuator management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5503-335\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mm × 160 mm × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet 5200 CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014042712,"sku":"5503-335","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5503-335-z04xb5vbkor.png?v=1756197214"},{"product_id":"woodward-5466-352-netcon-cpu-040-module","title":"Woodward 5466-352 NetCon CPU 040 Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Woodward \u003cstrong\u003e5466-352\u003c\/strong\u003e NetCon CPU 040 WO LL Memory Module is a high-performance control unit engineered for demanding industrial automation and process control environments. With robust I\/O capabilities and advanced fault-handling logic, this CPU module ensures reliable operation across a wide range of applications.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 5466-352\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: MicroNet Digital Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCPU Type\u003c\/strong\u003e: 040 WO LL Memory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e: 4 channels, 12-bit resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e: 2 channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDigital I\/O\u003c\/strong\u003e: 8 inputs + 8 outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e: Modbus RTU, CANopen\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eService Panel Access\u003c\/strong\u003e: For standalone MicroNet systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReset Options\u003c\/strong\u003e: Manual toggle or AppManager control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIOLOCK Safety Logic\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eActivates on CPU or I\/O failure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDe-energizes all output circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSends IOLOCK signal to all modules and racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C to +85°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Range\u003c\/strong\u003e: 10–32 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5466-352\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mm × 160 mm × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014141016,"sku":"5466-352","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5466-352-lfb3gw331gb.png?v=1756197218"},{"product_id":"woodward-9905-970-linknet-input-module-24-vdc-6-analog-channels-160-160-12-mm-0-10-v-0-20-ma-range","title":"Woodward 9905-970 LinkNet 6-Channel Analog Input Module","description":"\u003ch3\u003eScalable Analog Monitoring for Turbine Control Systems\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cstrong\u003e \u003c\/strong\u003eWoodward \u003cstrong\u003e9905-970\u003c\/strong\u003e is a precision analog input module from the LinkNet 9900 Series, designed to deliver up to six high-accuracy analog signals to turbine control systems. Manufactured by Woodward Inc\u003cstrong\u003e.\u003c\/strong\u003e, this module enables real-time monitoring of critical parameters such as temperature, pressure, and flow rate, allowing for optimized turbine performance and safe operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSix analog input channels for simultaneous multi-parameter monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports 0–10 V and 0–20 mA input ranges for flexible sensor integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh measurement accuracy ensures reliable turbine control decisions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlug-and-play installation with user-friendly configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScalable design compatible with other \u003cstrong\u003eLinkNet\u003c\/strong\u003e components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for turbine systems requiring dynamic performance adjustments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eLinkNet 9900 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9905-970\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0–10 V \/ 0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm × 160 mm × 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eLinkNet 6-Channel Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014239320,"sku":"9905-970","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-9905-970-v1lak2nkd5s.png?v=1756197220"},{"product_id":"woodward-5464-654-discrete-output-module","title":"Woodward 5464-654 Discrete Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Woodward \u003cstrong\u003e5464-654\u003c\/strong\u003e is a high-density 64-channel discrete output module designed for MicroNet™ Digital Control Systems. It delivers non-isolated relay driver signals in response to CPU commands, enabling precise control of field-connected devices such as prime movers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 5464-654\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: MicroNet Digital Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e: 64 discrete outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e: Relay driver signals (non-isolated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e: No potentiometers or calibration required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Ready\u003c\/strong\u003e: Plug-and-play replacement with same part number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFTM Configurations\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual FTM I\/O options\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDaisy-chained relay module connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard guide chassis mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual screw retention\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eToggle handles for safe disengagement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: External 24 Vdc power for relay modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5464-654\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mm × 160 mm × 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014632536,"sku":"5464-654","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5464-654-ntlemvg1ygh.png?v=1756197229"},{"product_id":"woodward-5464-648-analog-output-module","title":"Woodward 5464-648 Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Woodward \u003cstrong\u003e5464-648\u003c\/strong\u003e is a precision-engineered 8-channel analog output module designed for MicroNet™ Digital Control Systems, specifically in gas turbine applications. It delivers configurable analog signals—voltage or current—to control external devices and processes with high accuracy and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 5464-648\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: MicroNet Digital Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e: 8 independent analog outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e: Configurable voltage (e.g., 0–10V) or current (4–20mA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution \u0026amp; Accuracy\u003c\/strong\u003e: High-resolution output with tight tolerance control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e: Compatible with Modbus, Profibus, EtherCAT (system dependent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Programmable output ranges, scaling factors, and signal parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignal quality monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFault detection and reporting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLED indicators for status and error conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e: Protects control system from voltage spikes and ground loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntegration\u003c\/strong\u003e: Interfaces with PLCs and DCS for turbine and industrial automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 99.9624%; height: 143.216px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 25.6023px;\"\u003e\n\u003cth style=\"width: 36.4357%; height: 25.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"width: 60.8654%; height: 25.6023px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 36.4357%; height: 19.6023px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.8654%; height: 19.6023px;\"\u003e\u003cstrong\u003e5464-648\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 36.4357%; height: 19.6023px;\"\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.8654%; height: 19.6023px;\"\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 36.4357%; height: 19.6023px;\"\u003e\u003cstrong\u003eCurrent Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.8654%; height: 19.6023px;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 36.4357%; height: 19.6023px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.8654%; height: 19.6023px;\"\u003e160 mm × 160 mm × 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 36.4357%; height: 19.6023px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.8654%; height: 19.6023px;\"\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 36.4357%; height: 19.6023px;\"\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.8654%; height: 19.6023px;\"\u003eMicroNet Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014665304,"sku":"5464-648","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5464-648-410mf20ihpf.png?v=1756197230"},{"product_id":"woodward-5464-643-discrete-input-module","title":"Woodward 5464-643 Discrete Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cstrong\u003e \u003c\/strong\u003eWoodward \u003cstrong\u003e5464-643\u003c\/strong\u003e is a robust 48-channel discrete input module engineered for MicroNet™ Digital Control Systems. Designed to interface with field switches and relays, each input channel is optically isolated to protect internal circuitry and ensure accurate signal transmission.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 5464-643\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: MicroNet Digital Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 48 optically isolated discrete inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Source\u003c\/strong\u003e: Field switches and relays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Optical isolators per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e: VME bus for CPU data retrieval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFault Diagnostics\u003c\/strong\u003e: LED indicators per module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFTM Connectivity\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eJ1: Channels 1–24\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eJ2: Channels 25–48\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCard guide mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual screw retention\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eToggle handles for safe disengagement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Mapping\u003c\/strong\u003e: Channel labels match application software indexing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5464-643\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mm × 160 mm × 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014698072,"sku":"5464-643","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5464-643-eximcqgaygj.png?v=1756197231"},{"product_id":"woodward-5464-334-4-20-analog-input-module","title":"Woodward 5464-334 4-20 Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Woodward \u003cstrong\u003e5464-334\u003c\/strong\u003e is a high-performance 8-channel isolated 4–20mA analog input module engineered for MicroNet Digital Control Systems in turbine applications. Designed as part of the 5400 Series, this intelligent I\/O module ensures accurate signal acquisition, robust fault detection, and seamless integration with turbine control architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 5464-334\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: MicroNet 5400\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e: 4–20mA analog signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: 8 isolated inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSmart I\/O\u003c\/strong\u003e: Onboard microcontroller with fault detection and auto-calibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: Power-on self-test and fault signaling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Reference\u003c\/strong\u003e: Per-channel precision reference for calibration and diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFuse Access\u003c\/strong\u003e: Visible fuse with external access for easy replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eActuator Driver Support\u003c\/strong\u003e: Compatible with proportional actuator signals (0–25mA or 0–200mA DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5464-334\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mm × 160 mm × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014796376,"sku":"5464-334","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5464-334-xcrjzotzhgg.png?v=1756197234"},{"product_id":"woodward-5464-213-netcon-serial-i-o-card","title":"Woodward 5464-213 Netcon Serial I\/O Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Woodward \u003cstrong\u003e5464-213 \u003c\/strong\u003eNetcon Serial I\/O Card is a smart module designed for MicroNet Digital Control systems. It features onboard microcontrollers that manage rate-group scheduling, fault detection, and automatic calibration with minimal CPU intervention. During initialization, the module performs self-tests and signals operational status via LED indicators.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003e5464-213\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Woodward\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: MicroNet Digital Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSmart I\/O Functionality\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOnboard microcontroller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRate-group scheduling via CPU broadcast\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic calibration and fault detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff = Initialized\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOn = I\/O fault\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Monitoring\u003c\/strong\u003e: Precision voltage reference per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Monitoring\u003c\/strong\u003e: Voltage\/current fault detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFuse Access\u003c\/strong\u003e: Replaceable via housing cutout\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5464-213\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mm × 160 mm × 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161014992984,"sku":"5464-213","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-5464-213-lsrgrxqiegs.png?v=1756197239"},{"product_id":"ge-is230trlsh2b-relay-output-module","title":"GE IS230TRLSH2B Relay Output Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS230TRLSH2B\u003c\/strong\u003e Relay Output Module is a robust solution for discrete safety output applications within the\u003cstrong\u003e \u003c\/strong\u003eMark VIe system. It includes two key components: the IS220YDOAS1A I\/O pack and a relay contact output terminal board. Designed for DIN-rail mounting, this module supports flexible wetting and fusing configurations, enabling tailored voltage isolation, redundancy, and terminal block styles for demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS230TRLSH2B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eRelay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e340 mm × 249 mm × 153 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Pack\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eIS220YDOAS1A\u003c\/strong\u003e (shared across modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSupports wetting\/fusing daughterboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes discrete output I\/O pack and relay terminal board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with multiple DIN-rail mounted configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports contact wetting and fusing for voltage isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnables redundancy and flexible terminal block styles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for safety-critical applications with modular scalability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrates seamlessly with GE Mark VIe control architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015156824,"sku":"IS230TRLSH2B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS230TRLSH2B-m0p5wajxp2v.png?v=1756197243"},{"product_id":"ge-is230tcish6c-din-rail-i-o-module","title":"GE IS230TCISH6C DIN Rail I\/O Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS230TCISH6C\u003c\/strong\u003e DIN Rail I\/O Module delivers configurable redundancy for discrete input processing in Mark VIe control systems. Supporting both Simplex and Triple Modular Redundant (TMR) configurations, it enables users to tailor system availability and SIL compliance. When paired with the TBCI terminal board, the module performs 2-out-of-3 voting in TMR mode, while Simplex and Dual setups rely on single or first-reporting YDIA I\/O packs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 99.9624%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 41.2228%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 58.4918%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003eMark VIe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003e\u003cstrong\u003eIS230TCISH6C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003eDIN Rail I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003e170 mm × 157 mm × 153 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eConfiguration Modes\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003eSimplex, Dual, TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eI\/O Pack\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003eCompatible with \u003cstrong\u003eYDIA\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.2228%;\"\u003eTerminal Board\u003c\/td\u003e\n\u003ctd style=\"width: 58.4918%;\"\u003eSupports \u003cstrong\u003eTBCI\u003c\/strong\u003e for TMR voting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports Simplex, Dual, and TMR configurations for flexible redundancy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTMR mode enables 2-out-of-3 voting for high-integrity input validation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimplex mode uses a single\u003cstrong\u003e \u003c\/strong\u003eYDIA I\/O pack for streamlined control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual mode listens to the first reporting I\/O pack without voting logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail mounting simplifies integration into compact control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for safety-critical systems requiring configurable SIL levels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015189592,"sku":"IS230TCISH6C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS230TCISH6C-4pefgvj1lka.png?v=1756197245"},{"product_id":"ge-is200tbcis2c-contact-input-terminal-board","title":"GE IS200TBCIS2C Contact Input Terminal Board","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS200TBCIS2C\u003c\/strong\u003e Contact Input With Group Isolation Terminal Board is designed to handle 24 dry contact inputs with built-in surge and noise suppression. As part of the Mark VIe system, it supports Simplex, Dual, and Triple Modular Redundant (TMR) configurations, offering flexible integration for safety-critical applications. Its barrier-type terminal blocks and shielded grounding ensure robust field wiring and easy maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200TBCIS2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eContact Input With Group Isolation Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e330 mm × 102 mm × 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e24 dry contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBarrier-type, unpluggable blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003eUp to #12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eShield terminal strip to chassis ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSimplex, Dual, TMR via JR1, JS1, JT1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Voltage\u003c\/td\u003e\n\u003ctd\u003eConnected via JE1 and JE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Protection\u003c\/td\u003e\n\u003ctd\u003eSurge and high-frequency suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccepts 24 dry contact inputs with group isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo barrier-type terminal blocks simplify wiring and maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports Simplex, Dual, and TMR configurations for flexible redundancy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShield terminal strips ensure proper grounding and EMI protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNoise suppression circuitry protects against surge and interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail compatible with side-mounting brackets for I\/O packs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEthernet connectivity supports one or two cables per I\/O pack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015255128,"sku":"IS200TBCIS2C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200TBCIS2C-hxh0ywkijy3.png?v=1756197246"},{"product_id":"ge-is220pclah1b-core-analog-i-o-module","title":"GE IS220PCLAH1B Core Analog I\/O Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS220PCLAH1B\u003c\/strong\u003e Core Analog I\/O Module is engineered for high-density analog signal acquisition in\u003cstrong\u003e \u003c\/strong\u003eMark VIe distributed control systems, specifically for aero-derivative gas turbines. It supports a wide range of input types including thermocouples, RTDs, voltage, and 4–20 mA current loops, and is compatible with both SCLT and SCLS terminal boards. This module adapts to Simplex, Dual, and TMR configurations, offering scalable redundancy and flexible signal routing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe distributed control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS220PCLAH1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eCore Analog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 mm × 120 mm × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, Voltage, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Boards\u003c\/td\u003e\n\u003ctd\u003eCompatible with \u003cstrong\u003eSCLT\u003c\/strong\u003e and \u003cstrong\u003eSCLS\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Modes\u003c\/td\u003e\n\u003ctd\u003eSimplex, Dual, TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports multiple analog input types for turbine control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with \u003cstrong\u003eSCLT\u003c\/strong\u003e for fanned inputs and \u003cstrong\u003eSCLS\u003c\/strong\u003e for dedicated signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperates in Simplex, Dual, or TMR configurations for flexible redundancy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact 180 × 120 × 30 mm design fits standard control enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight 1 kg module simplifies installation and maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for high-integrity analog signal processing in critical applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015287896,"sku":"IS220PCLAH1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS220PCLAH1B-vjzyuhugu5w.png?v=1756197247"},{"product_id":"ge-ds200tcqag1b-analog-i-o-board","title":"GE DS200TCQAG1B Analog I\/O Board","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE DS200TCQAG1B\u003c\/strong\u003e Analog I\/O Board (TCQA) is a high-performance signal conditioning module designed for Mark V Speedtronic control systems. It processes a wide range of analog inputs and outputs from terminal boards mounted on I\/O cores \u0026lt;r1\u0026gt;, \u0026lt;r2\u0026gt;, and \u0026lt;r3\u0026gt;, including LVDT, servo valve, thermocouple, vibration, pulse, and 4–20 mA signals. The board interfaces with the STCA and TCQC boards via 3PL and JE connectors, ensuring seamless data exchange and control coordination.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDS200TCQAG1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e378 mm × 378 mm × 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eLVDT, Thermocouple, 4–20 mA, Voltage, Vibration, Pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e3PL (to STCA), JE (to TCQC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conditioning\u003c\/td\u003e\n\u003ctd\u003eFuel flow, compressor stall-detect, generator\/line inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConditions multiple analog signals for turbine and generator control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with STCA and TCQC boards for signal routing and feedback\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports 4–20 mA loops, thermocouples, LVDTs, and vibration sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact 378 × 378 × 22 mm footprint fits standard control racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight 0.8 kg board simplifies handling and installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for fuel flow, stall detection, and generator signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015320664,"sku":"DS200TCQAG1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-DS200TCQAG1B-5faulp14a4n.png?v=1756197247"},{"product_id":"ge-is200scsas1a-i-o-expansion-board","title":"GE IS200SCSAS1A I\/O Expansion Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200SCSAS1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O Expansion Board from GE enhances input capacity for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIeS Control System\u003c\/strong\u003e. It connects to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTCSA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal board via serial links and supports the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYSIL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule with a wide range of input and output channels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200SCSAS1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIeS Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 cm × 18 cm × 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e10 × 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Outputs\u003c\/td\u003e\n\u003ctd\u003e10 × 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e6 × 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Inputs\u003c\/td\u003e\n\u003ctd\u003e3 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Inputs\u003c\/td\u003e\n\u003ctd\u003e3 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Outputs\u003c\/td\u003e\n\u003ctd\u003e3 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eSerial link to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTCSA\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports multiple input types including analog, thermocouple, and contact signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides transmitter power outputs for field devices at 24 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables ETR logic integration using TMR input sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact 0.2 kg board fits easily into control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnects directly to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTCSA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal board via serial interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015451736,"sku":"IS200SCSAS1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200SCSAS1A-fecijnlsafl.png?v=1756197250"},{"product_id":"ge-is220ppdah1b-power-distribution-feedback-i-o-pack","title":"GE IS220PPDAH1B Power Distribution Feedback I\/O Pack","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS220PPDAH1B\u003c\/strong\u003e Power Distribution System Feedback I\/O Pack is a compact, plug-and-play module designed to monitor and report critical power distribution parameters within the Mark VIe and Mark VIeS control systems. It collects feedback from up to six connected power distribution boards, including bus voltages, branch circuit status, ground fault detection, and bulk power supply health, and transmits this data via a dual redundant Ethernet interface to system controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS220PPDAH1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ePower Distribution System Feedback I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e82.6 mm × 41.9 mm × 121 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e340 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sources\u003c\/td\u003e\n\u003ctd\u003eUp to 6 power distribution boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDual redundant Ethernet (IONet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eJPDS, JPDM, JPDG, JPDC, JPDB, JPDE, JPDF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003ePlug-and-play with electronic ID recognition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccepts feedback from up to six power distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMonitors power bus voltages, branch circuit status, and ground fault conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides bulk power supply health diagnostics to controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual Ethernet ports ensure redundant communication with Mark VIe\/VIeS systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlug-and-play setup using electronic ID detection and ToolboxST configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact 82.6 × 41.9 × 121 mm form factor for easy integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight 340 g design supports flexible mounting options\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015582808,"sku":"IS220PPDAH1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS220PPDAH1B-4onwfkvbwi1.png?v=1756197253"},{"product_id":"ge-is200trtdh1d-rtd-input-terminal-board","title":"GE IS200TRTDH1D RTD Input Terminal Board","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS200TRTDH1D\u003c\/strong\u003e RTD Input Terminal Board is designed to interface with up to 16 three-wire RTD sensors, providing accurate temperature signal acquisition for Mark VIe control systems. It supports simplex configurations and connects to two PRTD I\/O packs, which convert analog RTD signals into digital values for controller processing. Integrated noise suppression circuitry ensures reliable performance in electrically noisy environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 99.9624%; height: 294.034px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 33.5949%; height: 19.6023px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 63.7062%; height: 19.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eMark VIe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003e\u003cstrong\u003eIS200TRTDH1D\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eRTD Input Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003e177.8 mm × 330.2 mm × 20.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eRTD Channels\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003e16 three-wire RTD inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eTerminal Type\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eBarrier-type blocks (2 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eWorks with PRTD I\/O packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eFiltering\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eStandard scan rate compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eIsolation\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eGalvanic isolation via PRTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 33.5949%; height: 19.6023px;\"\u003eApplication Mode\u003c\/td\u003e\n\u003ctd style=\"width: 63.7062%; height: 19.6023px;\"\u003eSimplex only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccepts 16 RTD inputs via two barrier-type terminal blocks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with PRTD I\/O packs for digital temperature conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides galvanic isolation and transient protection for RTD circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated surge and high-frequency noise suppression circuitry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports simplex applications in Mark VIe control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFiltering optimized for standard scan rate performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact and lightweight design for easy panel integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015615576,"sku":"IS200TRTDH1D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200TRTDH1D-evbio4agz2k.png?v=1756197254"},{"product_id":"ge-is200tbais1c-analog-input-output-terminal-board","title":"GE IS200TBAIS1C Analog Input\/Output Terminal Board","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS200TBAIS1C\u003c\/strong\u003e Analog Input\/Output Terminal Board is a compact and flexible module designed for Mark VIe control systems. It supports 10 analog inputs and 2 analog outputs, accommodating various transmitter configurations including two-wire, three-wire, four-wire, and externally powered types. With integrated noise suppression circuitry, the board ensures reliable signal integrity in high-interference environments. It supports both Simplex and Triple Modular Redundant (TMR) configurations, enabling scalable redundancy for critical control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200TBAIS1C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e101.6 mm × 330.2 mm × 23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e10 channels (2W\/3W\/4W\/external power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels (0–20 mA; 0–200 mA with PAICH2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e3 × DC-37 pin for TMR; JR1 for Simplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Protection\u003c\/td\u003e\n\u003ctd\u003eSurge and high-frequency noise suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Regulation\u003c\/td\u003e\n\u003ctd\u003eShunt-based current measurement for TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports multiple analog input configurations for flexible transmitter integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo analog outputs configurable for 0–20 mA or 0–200 mA (with \u003cstrong\u003ePAICH2\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTMR mode fans input signals to R, S, and T I\/O packs for redundancy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCombines output currents via shunt for precise regulation in TMR setups\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimplex mode supported via single JR1 connector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact and lightweight design for efficient panel integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in noise suppression ensures stable signal acquisition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015648344,"sku":"IS200TBAIS1C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200TBAIS1C-jhb0dnp300x.png?v=1756197255"},{"product_id":"ge-is230taish2c-tmr-analog-i-o-module","title":"GE IS230TAISH2C TMR Analog I\/O Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS230TAISH2C\u003c\/strong\u003e TMR DIN Rail Analog I\/O Module is engineered for high-integrity analog sig\u003cstrong\u003enal acquisition and output in Mark VIe safety control systems. It consists of the IS220YAICS1A I\/O pack and a DIN-rail mounted analog terminal board, supporting Triple Modular Redundancy (TMR) and Simplex configurations. In TMR mode, the controller selects the median input value to r\u003c\/strong\u003eeject outliers, while a patented output circuit ensures faulty I\/O packs are excluded from signal generation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 99.9624%; height: 313.637px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 26.986%; height: 19.6023px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 70.3151%; height: 19.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003eMark VIe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e\u003cstrong\u003eIS230TAISH2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003eTMR DIN Rail Analog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e170 mm × 157 mm × 153 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eI\/O Pack\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e\u003cstrong\u003eIS220YAICS1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eTerminal Board\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003eDIN-rail mounted, supports TMR\/Simplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e10 channels (2W\/3W\/4W\/external power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e2 channels (0–20 mA configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eConnectors\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003e3 × DC-37 for TMR, 1 × JR1 for Simplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eSignal Protection\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003eSurge and high-frequency noise suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 26.986%; height: 19.6023px;\"\u003eOutput Logic\u003c\/td\u003e\n\u003ctd style=\"width: 70.3151%; height: 19.6023px;\"\u003eMedian selection and fault rejection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports 10 analog inputs and 2 configurable outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with two-wire, three-wire, four-wire, and externally powered transmitters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTMR configuration selects median input to reject faulty signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePatented output circuitry excludes underperforming I\/O packs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNoise suppression circuitry ensures stable signal acquisition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN-rail mounting simplifies integration into compact control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for safety-critical applications requiring redundancy and precision\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015681112,"sku":"IS230TAISH2C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS230TAISH2C-hx5v4xovtce.png?v=1756197257"},{"product_id":"ge-is200vrtdh1d-rtd-input-board","title":"GE IS200VRTDH1D RTD Input Board","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS200VRTDH1D\u003c\/strong\u003e Resistance Temperature Device (RTD) Input Board is designed to process temperature signals from up to 16 three-wire RTDs in Mark VI gas turbine control systems. It interfaces with TRTD or DRTD terminal boards via molded cables and performs excitation, signal conditioning, and digital conversion. The processed temperature data is transmitted through the VME backplane to the VCMI and ultimately to the system controller for real-time monitoring and control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI gas turbine control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200VRTDH1D\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eResistance Temperature Device Input Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 mm × 160 mm × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Channels\u003c\/td\u003e\n\u003ctd\u003e16 three-wire RTD inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Board\u003c\/td\u003e\n\u003ctd\u003eCompatible with \u003cstrong\u003eTRTD\u003c\/strong\u003e or \u003cstrong\u003eDRTD\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conversion\u003c\/td\u003e\n\u003ctd\u003eDigital temperature values via VME backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Path\u003c\/td\u003e\n\u003ctd\u003eVRTD → VCMI → Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExcites and reads 16 RTD signals for accurate temperature monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConverts analog RTD inputs into digital values for turbine control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with TRTD or DRTD terminal boards using molded cables\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransfers data through VME backplane to VCMI and controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact 180 × 160 × 30 mm design fits standard VME rack configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for high-reliability temperature sensing in gas turbine systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015746648,"sku":"IS200VRTDH1D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200VRTDH1D-avtn033v1t1.png?v=1756197258"},{"product_id":"ge-ds200tcpsg1a-dc-input-power-supply-board","title":"GE DS200TCPSG1A DC Input Power Supply Board","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE DS200TCPSG1A\u003c\/strong\u003e DC Input Power Supply Board is a compact and efficient module designed to convert 125 Vdc input into multiple regulated voltage levels required by the Mark V gas turbine control system. Installed within the system’s core I\/O racks, it supplies power for critical functions including microprocessor operation, mA output loops, RTD excitation, and servo valve control. Its integration ensures stable and isolated power delivery across diverse control components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V gas turbine control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDS200TCPSG1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eDC Input Power Supply Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e240 mm × 180 mm × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Functions\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor, RTD, mA loop, servo valve power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConverts 125 Vdc input into multiple control-level voltages\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePowers microprocessors, RTDs, servo valves, and analog output circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact 240 × 180 × 20 mm footprint fits standard I\/O cores\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight 0.4 kg design simplifies installation and maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsures stable voltage regulation across turbine control subsystems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegral to the Mark V control architecture for gas turbine systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161015844952,"sku":"DS200TCPSG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-DS200TCPSG1A-bdluejjzllj.png?v=1756197259"},{"product_id":"abb-spdsi14-digital-input-module","title":"ABB SPDSI14 Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eSPDSI14\u003c\/strong\u003e Digital Input Module from ABB’s Symphony Plus System processes up to 16 discrete field inputs with high reliability and precision. Each channel is optically isolated, ensuring robust signal integrity and protection against electrical noise. The module operates with a fixed input voltage of 48 VDC, making it suitable for industrial-grade digital signal acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSPDSI14\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (Optically Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e48 VDC (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e358.14 mm × 266.7 mm × 73.66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eApplications \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eSPDSI14\u003c\/strong\u003e module is ideal for industrial automation systems requiring multiple digital inputs with electrical isolation. It integrates seamlessly with ABB’s Symphony Plus controllers and supports centralized monitoring and control in energy, utility, and manufacturing sectors. Its compatibility with 48 VDC field signals makes it suitable for high-voltage digital input environments.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43161015943256,"sku":"SPDSI14","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ABB-SPDSI14-15lgqbqflcj.png?v=1756197264"},{"product_id":"abb-2002nz10801c-modcell-multiloop-processor","title":"ABB 2002NZ10801C MODCELL Multiloop Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003e2002NZ10801C\u003c\/strong\u003e MODCELL Multiloop Processor is a high-speed event monitoring unit designed for MicroMod process control systems. It scans up to 29 digital inputs every millisecond, applying debounce filtering and timestamping transitions for precise event tracking.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2002NZ10801C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroMod Process Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiloop Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 29 scanned per millisecond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent Queue Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 millisecond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSync Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485 \/ OMEGA navigational system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e221 × 482 × 153\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Speed Scanning\u003c\/strong\u003e: Monitors 29 digital inputs every millisecond\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePrecise Timestamping\u003c\/strong\u003e: Embedded real-time clock with 1 ms resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEvent Logging\u003c\/strong\u003e: Stores up to 1024 transitions for SOE analysis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Synchronization\u003c\/strong\u003e: RS-485 or OMEGA-based time sync across units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePre-Configured Database\u003c\/strong\u003e: Identity Module includes controller firmware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModular Expansion\u003c\/strong\u003e: Combine multiple units for extended input capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication \u0026amp; Use Case\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2002NZ10801C\u003c\/strong\u003e MODCELL is ideal for industrial automation, motor control, and alarm sequencing where precise input state tracking is critical. Its fast scanning and timestamping capabilities make it a cornerstone for event-driven diagnostics, safety systems, and process optimization.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43161016107096,"sku":"2002NZ10801C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ABB-2002NZ10801C-lhqypn3nfyn.png?v=1756197270"},{"product_id":"abb-mpm810-processor-module","title":"ABB MPM810 Processor Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessor Module executes selected functions of the MCM800 system while providing communication through Profibus DP or Modbus RTU. Engineers rely on its compact design, LED indicators, and robust protection features to ensure reliable performance in demanding automation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMPM810\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMPM810\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e192 × 82 × 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eDCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Origin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Time\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eresides in an open ventilated plastic enclosure, ensuring efficient cooling and durability. Eleven LEDs on the front panel provide clear indication of module and I\/O status, simplifying diagnostics. Engineers replace the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeasily in a fully operational I\/O station, minimizing downtime. Its design protects against excessive voltage or current, ensuring long-term reliability.\u003c\/p\u003e\n\u003ch3\u003eDesign and Build\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasures 192x82x61mm and weighs only 0.15kg, making it lightweight and easy to install. Its architecture supports safe integration with Termination Base Unit\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTBU850\u003c\/strong\u003e, while maintaining stable communication with control systems.\u003c\/p\u003e\n\u003ch3\u003eApplications and Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessor Module integrates seamlessly with Symphony Plus systems and MCM800 architecture. Engineers deploy it in power generation, manufacturing, and process industries requiring reliable Profibus DP or Modbus RTU communication. Its compact build and diagnostic LEDs make it ideal for environments demanding high availability and quick fault detection.\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompact 0.15kg design supports space-constrained installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEleven LED indicators simplify monitoring and diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProfibus DP and Modbus RTU communication ensure versatile integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection against excessive voltage and current enhances durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43161017090136,"sku":"MPM810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ABB-MPM810-ol3i0at4oq2.png?v=1756197299"},{"product_id":"abb-eim810-extended-i-o-module","title":"ABB EIM810 Extended I\/O Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEIM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtended I\/O Module expands predefined I\/O capability for turbine specialty modules. Engineers rely on its compact design and robust performance to handle significant hardwired I\/O requirements, including connections to local panels with meters and switches.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEIM810\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eExtended I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e192 × 82 × 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eDCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Origin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOQ\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Time\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEIM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports additional hardwired I\/O signals, making it ideal for applications requiring extensive panel interfacing. Engineers benefit from its ability to integrate seamlessly into turbine specialty modules or operate as a standalone solution. Its design ensures reliable signal conversion and efficient data handling in real-time monitoring environments.\u003c\/p\u003e\n\u003ch3\u003eDesign and Build\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEIM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasures 192x82x61mm and weighs 0.39kg, offering a compact yet durable build. Its modular architecture simplifies installation and maintenance, while energy-efficient operation reduces costs. The unit withstands demanding industrial conditions, ensuring consistent performance across diverse applications.\u003c\/p\u003e\n\u003ch3\u003eApplications and Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEIM810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtended I\/O Module integrates with Symphony Plus systems and turbine specialty modules. Engineers deploy it in power generation, process control, and manufacturing industries requiring expanded I\/O capacity. Its adaptability makes it suitable for both centralized and standalone configurations.\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompact 0.39kg design supports space-constrained installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides additional predefined I\/O capability for turbine modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperates efficiently at 24V DC with 4–20mA current range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModular design simplifies installation and long-term maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43161017155672,"sku":"EIM810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ABB-EIM810-twwafnmo0dr.png?v=1756197299"},{"product_id":"abb-rom810-relay-output-module","title":"ABB ROM810 Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB\u003cstrong\u003e ROM810\u003c\/strong\u003e Relay Output Module is a compact, DIN-rail mountable unit designed to house up to\u003cstrong\u003e \u003c\/strong\u003etwo electro-mechanical relays for digital output signal control. Engineered for Symphony® Plus systems, it connects directly to the TBU810 termination base, forming a reliable interface for field I\/O and power distribution.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eROM810\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eSymphony® Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eRelay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Current\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e44 mm × 119 mm × 106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Quantity\u003c\/td\u003e\n\u003ctd\u003e2 per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003e2 form “C” contacts per relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Rating\u003c\/td\u003e\n\u003ctd\u003e5A @ 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Rating\u003c\/td\u003e\n\u003ctd\u003e3A @ 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback Functions\u003c\/td\u003e\n\u003ctd\u003eCoil activation, power failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppression\u003c\/td\u003e\n\u003ctd\u003eInductive kickback protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail with mechanical latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eDirect plug-in to TBU810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Support\u003c\/td\u003e\n\u003ctd\u003e2oo3 logic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eROM810\u003c\/strong\u003e is purpose-built for ABB Symphony® Plus control systems, providing robust relay-based digital output for process control, power generation, and safety-critical automation. Its compatibility with TBU810, compact design, and advanced feedback features make it a trusted choice for modular, scalable control architectures\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43161017188440,"sku":"ROM810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ABB-ROM810-bm5aolic2fh.png?v=1756197301"},{"product_id":"abb-cpm810-common-processor-module","title":"ABB CPM810 Common Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cstrong\u003e \u003c\/strong\u003eABB \u003cstrong\u003eCPM810\u003c\/strong\u003e is a compact and intelligent Common Processor Module designed for integration within the VP800 control architecture of the Symphony® Plus system. It executes core VP800 functions, interfaces with the VPM810 module, and communicates with the control system via Profibus DP, ensuring robust and deterministic data exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCPM810\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Catalog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSymphony® Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProfibus DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 × 119 × 106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExecutes VP800 Functions\u003c\/strong\u003e: Core logic processing for VP800 control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProfibus DP Interface\u003c\/strong\u003e: High-speed communication with control network\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDIP Switch Addressing\u003c\/strong\u003e: 7-switch configuration for Profibus address and redundancy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRedundant Mode Support\u003c\/strong\u003e: Enables fault-tolerant operation with synchronized address setup\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlash Mode Safeguard\u003c\/strong\u003e: Prevents accidental entry into flash programming mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Form Factor\u003c\/strong\u003e: Ideal for space-constrained control cabinets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43161017385048,"sku":"CPM810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ABB-CPM810-rxtjpzmkoet.png?v=1756197307"},{"product_id":"woodward-9905-969-linknet-6-channel-current-input-module","title":"Woodward 9905-969 LINKnet 6-Channel Current Input Module","description":"\u003ch3\u003eReliable Analog Signal Acquisition for Industrial Monitoring\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Woodward \u003cstrong\u003e9905-969\u003c\/strong\u003e is a precision current input module from the LINKnet series, designed to interface with six 4–20 mA transducers for real-time monitoring in industrial control systems. Manufactured by Woodward Inc., this module supports either loop-powered or self-powered transducers (not both simultaneously), ensuring accurate signal conversion and fault detection via its integrated reference voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSix 4–20 mA input channels for analog signal acquisition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports loop-powered or self-powered transducers (single mode per module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in reference voltage for A\/D converter integrity checks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFault annunciation through application software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-replaceable design for minimal system downtime\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRotary address switches for easy configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail mounting for streamlined installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eLINKnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9905-969\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Type\u003c\/td\u003e\n\u003ctd\u003eLoop-powered or self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm × 114 mm × 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eMicroNet Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161017483352,"sku":"9905-969","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-9905-969-4ln4bgnudxg.png?v=1756197308"},{"product_id":"ge-is430snuah1a-universal-i-o-module","title":"GE IS430SNUAH1A Universal I\/O Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS430SNUAH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal I\/O Module from GE’s Mark VIe series combines the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePUAAH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O pack with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSUAAH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal board to deliver flexible analog signal processing. It supports 16 simplex channels, each configurable as thermocouple, RTD, voltage input (±5 V or ±10 V), current input\/output, pulse accumulator, or digital input.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS430SNUAH1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eUniversal analog I\/O processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e260 mm × 220 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 configurable analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, Voltage, Current, Pulse, Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBPPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Board\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBCAR\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Boards\u003c\/td\u003e\n\u003ctd\u003e4 ×\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMIO\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euniversal analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Board\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSUAAH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith removable blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Tool\u003c\/td\u003e\n\u003ctd\u003eToolboxST application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eRoHS, GEH-6721_Vol_I standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161017581656,"sku":"IS430SNUAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS430SNUAH1A-zpjltp1pz31.png?v=1756197311"},{"product_id":"ge-is420puaah1a-universal-i-o-pack","title":"GE IS420PUAAH1A Universal I\/O Pack","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS420PUAAH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal I\/O Pack from GE’s Mark VIe series delivers scalable and cost-efficient I\/O integration for distributed control systems (DCS) and balance of plant (BoP) applications. Designed for environments with thousands of I\/O points, this module ensures high availability while reducing per-point cost.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS420PUAAH1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e260 mm × 80 mm × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003eModular three-wire channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommissioning\u003c\/td\u003e\n\u003ctd\u003eChannel-by-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Scope\u003c\/td\u003e\n\u003ctd\u003eDCS and BoP systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161017614424,"sku":"IS420PUAAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS420PUAAH1A-x1rtadf3inz.png?v=1756197311"},{"product_id":"ge-is200erioh1a-exciter-regulator-i-o-board","title":"GE IS200ERIOH1A Exciter Regulator I\/O Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200ERIOH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExciter Regulator I\/O Board from GE’s EX2100 regulator control system delivers robust I\/O interfacing for both customer and system signals. It supports simplex and redundant configurations, connecting to terminal boards like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEPCT\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eECTBG1\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eECTBG2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200ERIOH1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eEX2100 Regulator Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eExciter I\/O interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 cm × 16 cm × 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Architecture\u003c\/td\u003e\n\u003ctd\u003eDual-port memory (DPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Support\u003c\/td\u003e\n\u003ctd\u003eM1, M2, C (simplex and redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eDual 25-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPGA Role\u003c\/td\u003e\n\u003ctd\u003eData acquisition and memory control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Interfacing\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eEPCT\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eERDD\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEROCH1A\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eERRR\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161017811032,"sku":"IS200ERIOH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200ERIOH1A-0tfelxx0tx5.png?v=1756197317"},{"product_id":"woodward-9905-971-linknet-16-channel-discrete-input-module","title":"Woodward 9905-971 LINKnet 16 Channel Discrete Input Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eWoodward 9905-971\u003c\/strong\u003e is a compact and efficient discrete input module from the LINKnet series, designed to interface with field switches or relay contacts in industrial control systems. Manufactured by Woodward Inc., this unit offers sixteen 24 Vdc discrete inputs and integrates seamlessly with the NetCon control system, making it ideal for sequencing and monitoring tasks outside turbine control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSixteen discrete inputs for field switches or relay contacts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInternal filtered and fused power source or external 24 Vdc input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-replaceable module for minimal system downtime\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeamless integration with \u003cstrong\u003eNetCon\u003c\/strong\u003e control architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptimized for non-turbine functions such as sequencing and status monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEasy DIN rail installation and address configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eLINKnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9905-971\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm × 114 mm × 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Catalog\u003c\/td\u003e\n\u003ctd\u003eMicroNet Simplex Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43161017843800,"sku":"9905-971","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Woodward-9905-971-03ua4uz1unq.png?v=1756197317"},{"product_id":"ge-is200tsvch1a-servo-input-output-terminal-board","title":"GE IS200TSVCH1A Servo Input\/Output Terminal Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200TSVCH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eServo Input\/Output Terminal Board from GE’s Mark VIe series delivers precise control for turbine valve positioning. It supports two bi-directional servo current output channels, each with LVDT excitation, LVDT feedback, and pulse rate inputs for fuel flow monitoring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200TSVCH1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eServo I\/O with LVDT feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33.02 cm × 17.8 cm × 2.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServo Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVDT Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Rate Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Support\u003c\/td\u003e\n\u003ctd\u003eUp to 300 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Resistance\u003c\/td\u003e\n\u003ctd\u003e15 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Configurations\u003c\/td\u003e\n\u003ctd\u003e1–3 coil (simplex\/TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSuicide relay with manual reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161017942104,"sku":"IS200TSVCH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200TSVCH1A-p3b0e2ljlmo.png?v=1756197321"},{"product_id":"ge-is200tbtch1b-thermocouple-input-terminal-board","title":"GE IS200TBTCH1B Thermocouple Input Terminal Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200TBTCH1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThermocouple Input Terminal Board from GE’s Mark VIe series offers high-density temperature signal acquisition for industrial control systems. It supports 24 thermocouple inputs, including types E, J, K, S, and T. When paired with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePTCCH2\u003c\/strong\u003e, it also accepts B, N, and R types.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200TBTCH1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e24 thermocouple inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Types\u003c\/td\u003e\n\u003ctd\u003eE, J, K, S, T (B, N, R with PTCCH2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34 cm × 12 cm × 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 450 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003e300 m (984 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e2 removable, 24 terminals each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eJ-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Suppression\u003c\/td\u003e\n\u003ctd\u003eHigh-frequency filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJ Reference Devices\u003c\/td\u003e\n\u003ctd\u003e2 integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161017974872,"sku":"IS200TBTCH1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200TBTCH1B-v2vlwmk5wok.png?v=1756197321"},{"product_id":"ge-is200srtdh2a-rtd-input-terminal-board","title":"GE IS200SRTDH2A RTD Input Terminal Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200SRTDH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eResistance Temperature Device Input Terminal Board from GE’s Mark VIe series offers precise RTD signal acquisition in compact industrial setups. It features eight RTD input channels and communicates with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePRTD I\/O pack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough a DC-37 connector using Ethernet protocol.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200SRTDH2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 RTD inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e36 terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e159 mm × 102 mm × 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eDC-37 pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eDIN rail or cabinet bolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Type\u003c\/td\u003e\n\u003ctd\u003eShielded twisted triplet (#18 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Points\u003c\/td\u003e\n\u003ctd\u003eE1 and E2 screw holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018073176,"sku":"IS200SRTDH2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-GE-ur3ancskspx.png?v=1756197323"},{"product_id":"ge-is200stcih4a-simplex-contact-input-terminal-board","title":"GE IS200STCIH4A Simplex Contact Input Terminal Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200STCIH4A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom GE’s Mark VIe system is a simplex contact input terminal board engineered for high-density signal integration. It supports 24 discrete contact inputs energized by external 24, 48, or 125 Vdc sources. Its compact footprint and robust surge protection make it ideal for industrial control environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200STCIH4A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e24 contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e24 \/ 48 \/ 125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e159 mm × 102 mm × 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eDIN rail or cabinet bolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003e#18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eD-type connector with Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Suppression\u003c\/td\u003e\n\u003ctd\u003eSurge and high-frequency filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018105944,"sku":"IS200STCIH4A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200STCIH4A-jcz0igyvilx.png?v=1756197324"},{"product_id":"ge-is200staoh2a-simplex-analog-output-terminal-board","title":"GE IS200STAOH2A Simplex Analog Output Terminal Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200STAOH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom GE’s Mark VIe system is a simplex analog output terminal board engineered for precision current control. It features eight 0–20 mA analog outputs, each regulated by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePAOC I\/O pack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough a D-type connector. The board communicates with the controller via Ethernet, ensuring fast and accurate signal transmission.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200STAOH2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark VIe System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog outputs (0–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e159 mm × 102 mm × 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eDIN rail or cabinet bolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eEuro-block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Feature\u003c\/td\u003e\n\u003ctd\u003eOn-board ID chip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018138712,"sku":"IS200STAOH2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS200STAOH2A-ovw4bnwcvou.png?v=1756197325"},{"product_id":"ge-ds200tccag1b-common-analog-i-o-board","title":"GE DS200TCCAG1B Common Analog I\/O Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCCAG1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom GE’s Mark V series is a core analog I\/O board designed to scale and condition multiple signal types. It processes RTD inputs, thermocouple signals, shaft voltage and current, and 4–20 mA analog inputs and outputs. These conditioned signals transfer to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTCA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eboard via the 3PL data bus.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDS200TCCAG1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark V System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eRTD, Thermocouple, 4–20 mA, Shaft Voltage\/Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e28 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e240 mm × 180 mm × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e2PL, 3PL, JAA–JEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eCOREBUS via 3PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHardware jumpers + HMI software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018171480,"sku":"DS200TCCAG1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-DS200TCCAG1B-eb3350nq0wm.png?v=1756197328"},{"product_id":"ge-ds200tccag1b-common-analog-i-o-board-1","title":"GE DS200TCCAG1B Common Analog I\/O Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCCAG1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom GE’s Mark V series is a core analog I\/O board designed to scale and condition multiple signal types. It processes RTD inputs, thermocouple signals, shaft voltage and current, and 4–20 mA analog inputs and outputs. These conditioned signals transfer to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTCA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eboard via the 3PL data bus.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDS200TCCAG1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMark V System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eRTD, Thermocouple, 4–20 mA, Shaft Voltage\/Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e28 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e240 mm × 180 mm × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e2PL, 3PL, JAA–JEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eCOREBUS via 3PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eHardware jumpers + HMI software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018302552,"sku":"IS220PCLAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS220PCLAH1A-j1xi0jsyspo.png?v=1756197333"},{"product_id":"yokogawa-scp451-51-processor-module","title":"Yokogawa SCP451-51 Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa SCP451-51\u003c\/strong\u003e is a high-performance processor module built for mission-critical control in CENTUM VP and ProSafe-RS distributed control systems. Equipped with a MIPS R5000 processor and 32 MB main memory, it ensures fast and stable execution of control logic across industrial networks.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed Control Systems (DCS)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety Instrumented Systems (SIS)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess automation in oil \u0026amp; gas, chemical, and power sectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-availability industrial networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh environment installations requiring G3 compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSCP451-51\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eMIPS R5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVnet\/IP Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant, 100 Mbps, Full duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Compliance\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eUTP (CAT5e or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Distance\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Options\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC \/ 220–240 V AC \/ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -5\u003c\/td\u003e\n\u003ctd\u003eNo explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -1\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 150 mm × 100 mm × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43161018368088,"sku":"SCP451-51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Yokogawa-SCP451-51-buh1fsgn4g0.png?v=1756197333"},{"product_id":"yokogawa-aai143-h50-analog-output-module","title":"Yokogawa AAI143-H50 Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa AAI143-H50\u003c\/strong\u003e is a high-performance analog input module designed for CENTUM VP and CENTUM CS distributed control systems. Featuring 16 fully isolated input channels, it supports 4–20 mA current signals and integrates HART digital communication, enabling remote diagnostics, configuration, and calibration directly from the control room.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess control in oil \u0026amp; gas, chemical, and power industries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration with smart field devices using HART protocol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-precision data acquisition in DCS systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh industrial environments requiring isolated analog input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAAI143-H50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 (individually isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eHART (digital communication)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% FS @ 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e5 samples\/sec\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e270–350 Ω (ON), ≥500 kΩ (OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power\u003c\/td\u003e\n\u003ctd\u003e19–25.5 V DC (max 25 mA\/channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC ±10% (max 0.8 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 mm × 100 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20, ATEX Zone 2 \/ Class I Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -H\u003c\/td\u003e\n\u003ctd\u003eHART protocol enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -5\u003c\/td\u003e\n\u003ctd\u003eNo explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43161018433624,"sku":"AAI143-H50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Yokogawa-AAI143-H50-y3us3eywgrk.png?v=1756197335"},{"product_id":"yokogawa-aai543-h50-analog-output-module","title":"Yokogawa AAI543-H50 Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Yokogawa \u003cstrong\u003eAAI543-H50\u003c\/strong\u003e is a high-integrity analog output module engineered for use in CENTUM VP and CENTUM CS distributed control systems. Featuring 16 isolated output channels, it supports 4–20 mA analog signals and integrates HART digital communication, enabling enhanced diagnostics and remote configuration of field devices such as valve positioners and smart transmitters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed Control Systems (DCS)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eValve positioner control and diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmart transmitter configuration via HART\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess automation in oil \u0026amp; gas, chemical, and power sectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundant control architectures requiring stable analog output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAAI543-H50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 (individually isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eHART (digital communication)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% FS @ 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Resistance\u003c\/td\u003e\n\u003ctd\u003e250–600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power\u003c\/td\u003e\n\u003ctd\u003e19–25.5 V DC (max 25 mA\/channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 mm × 100 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -H\u003c\/td\u003e\n\u003ctd\u003eHART protocol enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -5\u003c\/td\u003e\n\u003ctd\u003eNo explosion protection, redundant-ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code -0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43161018466392,"sku":"AAI543-H50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/Yokogawa-AAI543-H50-xvloszrjwuv.png?v=1756197340"},{"product_id":"ge-is230snaih2a-analog-i-o-din-rail-module","title":"GE IS230SNAIH2A Analog I\/O DIN Rail Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNAIH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog I\/O DIN Rail Module from GE provides a reliable interface between process sensors and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol logic. It includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O pack and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200STAIH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal board, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 analog inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 analog outputs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module accommodates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo-wire\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree-wire\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour-wire\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexternally powered transmitters\u003c\/strong\u003e. Outputs are configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecurrent loops. An onboard ID chip enables system diagnostics and automatic board recognition.\u003c\/p\u003e\n\u003cp\u003eThe DIN-rail mounting style offers flexibility for redundancy and terminal block configurations. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYAIC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O pack connects directly to the terminal board, streamlining installation and reducing wiring complexity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS230SNAIH2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (cm)\u003c\/td\u003e\n\u003ctd\u003e17.0 × 15.7 × 15.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e10 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels (0–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Pack\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Board\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200STAIH2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Support\u003c\/td\u003e\n\u003ctd\u003e2-wire, 3-wire, 4-wire, external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n\u003ctd\u003eOnboard ID chip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNAIH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for industrial automation, turbine control, and process monitoring. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esimplex configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand allows users to select setups based on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL level\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eavailability requirements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUse this module in systems requiring compact analog signal acquisition, flexible transmitter support, and seamless integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture. The combination of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200STAIH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures consistent performance across various installations.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018564696,"sku":"IS230SNAIH2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS230SNAIH2A-nuxcv1ik2qe.png?v=1756197342"},{"product_id":"ge-is400tbcis2c-contact-input-terminal-board-with-group-isolation","title":"GE IS400TBCIS2C Contact Input Terminal Board with Group Isolation","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS400TBCIS2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContact Input Terminal Board from GE is designed for high-integrity signal acquisition in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems. It accepts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 dry contact inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough two barrier-style terminal blocks and includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egroup isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enhanced safety.\u003c\/p\u003e\n\u003cp\u003eThis board supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esimplex\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTMR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurations. It connects to I\/O packs via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJR1\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJS1\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJT1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectors depending on system redundancy. The board features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enoise suppression circuitry\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect against surge and high-frequency interference.\u003c\/p\u003e\n\u003cp\u003eInstallation is straightforward with removable terminal blocks and side-mounted brackets for I\/O packs. The board uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJE1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJE2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplugs to connect to the excitation voltage source.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS400TBCIS2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark VIe \/ Mark VIeS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (cm)\u003c\/td\u003e\n\u003ctd\u003e34 × 10.16 × 5.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Inputs\u003c\/td\u003e\n\u003ctd\u003e24 dry contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e2 barrier-type, 24 terminals each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge Support\u003c\/td\u003e\n\u003ctd\u003eUp to #12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Suppression\u003c\/td\u003e\n\u003ctd\u003eSurge and high-frequency filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Modes\u003c\/td\u003e\n\u003ctd\u003eSimplex, Dual, TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eClass 1 Div 2 \/ Class 2 Zone 2 \/ ATEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 (with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYDIA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connectors\u003c\/td\u003e\n\u003ctd\u003eJE1, JE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS400TBCIS2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal board is ideal for industrial environments requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egroup isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehazardous location compliance\u003c\/strong\u003e. It integrates with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYDIA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O packs and supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61508\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety standards.\u003c\/p\u003e\n\u003cp\u003eUse this board in turbine control, process automation, and safety-critical systems. Its compact design and flexible mounting options make it suitable for space-constrained panels. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTBCIS2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 Vdc wetting voltage\u003c\/strong\u003e, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTBCIS3C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e48 Vdc\u003c\/strong\u003e.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018597464,"sku":"IS400TBCIS2C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS400TBCIS2C-v0jrb4dp3nn.png?v=1756197344"},{"product_id":"ge-is420ucpah2a-mark-vie-ucpa-controller-with-integral-i-o","title":"GE IS420UCPAH2A Mark VIe UCPA Controller with Integral I\/O","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS420UCPAH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUCPA Controller from GE combines control logic and I\/O in a single compact module. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esimplex IONet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication and integrates seamlessly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. This panel-mounted controller operates efficiently with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 Vdc power supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econsuming only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 W\u003c\/strong\u003e, making it ideal for low-power industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe controller includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS400WEXPH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexpansion board, adding\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix analog inputs\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo analog outputs\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour digital I\/Os\u003c\/strong\u003e, bringing the total to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight AIs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight DIOs\u003c\/strong\u003e. It functions reliably across a wide temperature range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to 70°C\u003c\/strong\u003e, without requiring a fan or battery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS420UCPAH2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e162 × 115 × 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eIntegrated + Expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 total (6 via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS400WEXPH1A\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/Os\u003c\/td\u003e\n\u003ctd\u003e8 total (4 via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS400WEXPH1A\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Support\u003c\/td\u003e\n\u003ctd\u003eControlST V05.04 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS420UCPAH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esimplex control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial automation and turbine systems. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eToolboxST\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration tools and integrates with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. Its compact footprint and integrated I\/O make it ideal for space-constrained panels.\u003c\/p\u003e\n\u003cp\u003eUse this controller in applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow power\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewide temperature tolerance\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecost-effective control\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIONet port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows expansion with external I\/O packs, enhancing flexibility without compromising reliability.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018630232,"sku":"IS420UCPAH2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS420UCPAH2A-3tmhvp3aqsy.png?v=1756197346"},{"product_id":"ge-is220pscah1b-serial-communication-i-o-pack","title":"GE IS220PSCAH1B Serial Communication I\/O Pack","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PSCAH1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSerial Communication I\/O Pack from GE provides a robust interface between Ethernet networks and serial terminal boards. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-232\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-422\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-485 half-duplex\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards across six configurable transceiver channels.\u003c\/p\u003e\n\u003cp\u003eThis I\/O pack includes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBPPC processor board\u003c\/strong\u003e, compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlST V04.07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand later. Input is handled via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual RJ-45 Ethernet ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3-pin power connector\u003c\/strong\u003e, while output connects through a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC-62 pin interface\u003c\/strong\u003e. Visual diagnostics are available through onboard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLED indicators\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PSCAH1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet Modbus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication in simplex configurations and features soft-start power control to manage inrush current during activation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS220PSCAH1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (cm)\u003c\/td\u003e\n\u003ctd\u003e8.3 × 4.2 × 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e340 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Board\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBPPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Channels\u003c\/td\u003e\n\u003ctd\u003e6 configurable ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-422, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 × RJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connector\u003c\/td\u003e\n\u003ctd\u003eDC-62 pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic LEDs\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e3-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDirect to SSCA terminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PSCAH1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for industrial systems requiring reliable serial communication. It integrates seamlessly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal boards such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSCA\u003c\/strong\u003e, and supports simplex and redundant configurations.\u003c\/p\u003e\n\u003cp\u003eUse this I\/O pack in turbine control, process automation, and distributed I\/O networks. Its flexible protocol support and compact footprint make it suitable for space-constrained installations with high data integrity requirements.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018663000,"sku":"IS220PSCAH1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS220PSCAH1B-ewgxpurajgr.png?v=1756197347"},{"product_id":"ge-is410tbcis2c-contact-input-terminal-board","title":"GE IS410TBCIS2C Contact Input Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS410TBCIS2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContact Input Terminal Board by GE is designed for high-integrity signal acquisition in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIeS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDual\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTMR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurations, offering flexible deployment across industrial environments.\u003c\/p\u003e\n\u003cp\u003eThis board accepts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 dry contact inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia two barrier-style terminal blocks. It uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edc I\/O wetting power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor contact excitation and includes built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enoise suppression\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guard against surges and high-frequency interference. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYDIA I\/O pack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emounts directly onto the board, streamlining installation and reducing wiring complexity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS410TBCIS2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark VIe \/ Mark VIeS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (cm)\u003c\/td\u003e\n\u003ctd\u003e34 × 24.9 × 15.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Inputs\u003c\/td\u003e\n\u003ctd\u003e24 dry contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e2 barrier-type blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Pack\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYDIA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Suppression\u003c\/td\u003e\n\u003ctd\u003eSurge and HF filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDirect I\/O pack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS410TBCIS2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eboard is ideal for safety-critical applications requiring reliable contact input processing. It integrates seamlessly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYDIA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O packs and supports multiple system configurations, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTMR redundancy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor fault tolerance.\u003c\/p\u003e\n\u003cp\u003eUse this board in turbine control, industrial automation, and process safety systems where clean signal acquisition and robust electrical isolation are essential. Its compact form factor and direct I\/O pack mounting simplify panel layout and reduce installation time.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018728536,"sku":"IS410TBCIS2C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS410TBCIS2C-2xq4csd2ig2.png?v=1756197348"},{"product_id":"ge-is400trlys1b-relay-output-terminal-board-with-coil-sensing","title":"GE IS400TRLYS1B Relay Output Terminal Board with Coil Sensing","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS400TRLYS1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay Output Terminal Board by GE features 12 plug-in magnetic relays for flexible control applications. Outputs 1–6 support jumper-configurable Form-C contacts or solenoid drivers. Outputs 7–11 offer isolated dry contacts, while Output 12 handles special loads like ignition transformers.\u003c\/p\u003e\n\u003cp\u003eThis board supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esimplex\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTMR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurations. Use connector\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor simplex setups and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJR1\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJS1\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJT1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor TMR systems. The board includes jumper-selectable fuses and suppression circuits for solenoid power management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS400TRLYS1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark VIe \/ Mark VIeS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e330 × 178 × 420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e12 magnetic relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003eForm-C (dry \/ solenoid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connectors\u003c\/td\u003e\n\u003ctd\u003eJF1, JF2, TB3, JG1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e2 blocks, 24 terminals each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge Support\u003c\/td\u003e\n\u003ctd\u003eUp to #12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 (with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS420YDOAS1B\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS400TRLYS1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eboard integrates with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIeS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems and supports safety-certified applications. It works with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS420YDOAS1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O packs and meets IEC 61508 standards. Use it in turbine ignition control, solenoid actuation, and industrial relay switching.\u003c\/p\u003e\n\u003cp\u003eThis board suits installations requiring isolated contacts, configurable outputs, and robust coil sensing. Jumper settings allow tailored power routing and suppression management for each relay channel.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":43161018761304,"sku":"IS400TRLYS1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-IS400TRLYS1B-k20qzstxydg.png?v=1756197349"}],"url":"https:\/\/www.industriaxplc.com\/collections\/plc-systems-modules.oembed?page=38","provider":"IndustriaX Limited","version":"1.0","type":"link"}