{"product_id":"yokogawa-anb10d-410-cu2n-ndel-s1-esb-bus-node-unit","title":"Yokogawa ANB10D-410\/CU2N\/NDEL S1 ESB Bus Node Unit","description":"\u003ch2\u003eYokogawa ANB10D-410\/CU2N\/NDEL S1 ESB Bus Node Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-410\/CU2N\/NDEL S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D\u003c\/strong\u003e Node Unit, operates as a dedicated hardware component for analog and digital field I\/O signal transmission within CENTUM VP and CENTUM CS 3000 distributed control systems. It provides direct physical execution for dual-redundant ESB bus communication and I\/O interfacing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ANB10D-410\/CU2N\/NDEL S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 kg (fully loaded), 2.4 kg (empty chassis with power supplies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm width, standard 19-inch rack-compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (operating), -20 to 60 degC (storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e200 VA \/ 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Slots\u003c\/td\u003e\n\u003ctd\u003e8 hot-swappable FIO slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC (-15% to +10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply modules installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount, M5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control \u0026amp;DCS Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ANB10D series supports 4-20 mA HART loop protocol and ensures channel-to-channel isolation across field I\/O modules. It accommodates FOUNDATION Fieldbus and PROFIBUS PA connectivity via the connector unit and provides cold junction compensation (CJC) for accurate thermocouple readings. Node expansion licenses (\/NDEL) enable interfacing with AFV10\/AFV30\/AFV40 and AFF50 controllers, ensuring deterministic signal routing and compliance with backplane bus communication requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: Does the ANB10D allow hot-swapping of FIO modules?\u003cbr\u003eA: Yes, all 8 I\/O slots support hot-swapping without disrupting ESB bus communication, provided proper sequence isolation is maintained.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum load on the ESB backplane bus?\u003cbr\u003eA: Each ANB10D supports the total current of installed FIO modules within the 200 VA chassis power rating; overload protection is internally managed by dual-redundant power supplies.\u003c\/p\u003e\n\u003cp\u003eQ: Can firmware updates be performed in the field?\u003cbr\u003eA: Firmware is compatible with S1 style revisions; updates require connecting through the FCU using Yokogawa’s standard ESB bus coupler interface modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInstall the ANB10D in a standard 19-inch rack using M5 screws, ensuring adequate airflow around the chassis.\u003c\/li\u003e\n\u003cli\u003eConnect the dual-redundant 100-120 V AC power supplies to separate circuits if possible to maintain redundancy.\u003c\/li\u003e\n\u003cli\u003eRoute ESB bus cables using shielded twisted pairs and terminate connectors according to the CU2N module specification.\u003c\/li\u003e\n\u003cli\u003eMaintain separation of analog and digital field wiring to reduce crosstalk and maintain channel-to-channel isolation.\u003c\/li\u003e\n\u003cli\u003eConfirm that ambient temperature does not exceed 60 degC and humidity remains within 5-95% non-condensing range.\u003c\/li\u003e\n\u003cli\u003eVerify hot-swap procedure by ensuring that power supplies remain operational and the FCU recognizes newly inserted FIO modules.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44202981261400,"sku":"ANB10D-410\/CU2N\/NDEL S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANB10D-410CU2NNDELS1-3.jpg?v=1780882249","url":"https:\/\/www.industriaxplc.com\/ar\/products\/yokogawa-anb10d-410-cu2n-ndel-s1-esb-bus-node-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}