{"product_id":"yokogawa-afv30d-s41152-duplexed-field-control-unit","title":"Yokogawa AFV30D-S41152 Duplexed Field Control Unit","description":"\u003ch2\u003eYokogawa AFV30D-S41152 Duplexed Field Control Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for real-time process communication and field I\/O connectivity in CENTUM VP platforms, the \u003cstrong\u003eYokogawa AFV30D-S41152\u003c\/strong\u003e (\u003cstrong\u003eAFV30D\u003c\/strong\u003e Duplexed Field Control Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFV30D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit (for Vnet\/IP and FIO, 19-inch Rack Mountable Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP network, dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type (with hardware specifications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type (with no specialized option code additions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFV30D-S41152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration (Supports CP451 \/ CP461)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Speed\u003c\/td\u003e\n\u003ctd\u003e350 MHz (VR5532 CPU architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Protection\u003c\/td\u003e\n\u003ctd\u003eBattery backup, max. 72 hours (Recharge time: min. 48 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Network\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP Interface (Dual-redundant), 1 Gbps Full Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Cable Type\u003c\/td\u003e\n\u003ctd\u003eCAT5e or better, UTP (RJ45 connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Network Distance\u003c\/td\u003e\n\u003ctd\u003e100 meters (From FCU to Layer 2 network switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable Nodes\u003c\/td\u003e\n\u003ctd\u003eMax. 13 to 14 nodes (Includes ESB Bus and ER Bus Node Units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Slots\u003c\/td\u003e\n\u003ctd\u003eSupports up to 8 FIO modules directly on the rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Contact Output\u003c\/td\u003e\n\u003ctd\u003e2 terminals (NC, C), points open during FCU failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 V DC, max. 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 8.0 kg (Fully equipped in duplexed configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack execution depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe architecture incorporates dedicated 4-20 mA HART loop protocol pass-through communication, enabling bidirectional variable transformation between field transmitters and the main processing units. Digital fieldbus options facilitate integrated FOUNDATION Fieldbus\/Profibus PA connectivity directly through connected node units. To safeguard systemic calculations, channel-to-channel isolation is enforced across the structural FIO subsystem backplane, preventing transient ground loop currents from destabilizing analog signals. For thermocouple monitoring cards deployed within the connected nodes, cold junction compensation (CJC) registers maintain precision thermal references directly at the terminal connection point.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What is the maximum switchover disruption duration during a processor fault condition?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The control transfers from the active processor module to the standby processor module within milliseconds, ensuring zero interruption to the ongoing control loop execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Can processor modules and power supply units be serviced while the unit is energized?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, the dual-redundant hardware layout supports online \"hot-swap\" maintenance, allowing the replacement of a faulty module while the system remains powered and executing active plant processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What happens to the status contact output terminals if the hardware experiences a critical failure?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The contact action is normally closed (NC). Upon detecting an internal FCU failure or complete power loss, the internal relay de-energizes, causing the points to open automatically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting Mechanical Constraints:\u003c\/strong\u003e Secure the chassis into a standard 19-inch rack structure using 8 x M5 screws. Insulation bushes must be utilized at each mounting point to electrically isolate the chassis frame from the rack structural ironwork.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Infrastructure:\u003c\/strong\u003e Connect a dedicated low-impedance copper ground wire from the functional grounding terminal of the chassis to the system instrument ground bus. Ensure the termination point resistance satisfies local industrial control room single-point grounding rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cable Run Limits:\u003c\/strong\u003e Route the CAT5e or higher Vnet\/IP UTP cables away from high-voltage AC lines or heavy inductive machinery motor leads. The total physical cable length from the RJ45 interface on the FCU module to the designated Layer 2 network switch must not exceed 100 meters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44187194556504,"sku":"AFV30D-S41152","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AFV30D-S41152-2.jpg?v=1780629416","url":"https:\/\/www.industriaxplc.com\/ar\/products\/yokogawa-afv30d-s41152-duplexed-field-control-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}