{"product_id":"yokogawa-afv10d-s41101-duplexed-field-control-unit","title":"Yokogawa AFV10D-S41101 Duplexed Field Control Unit","description":"\u003ch2\u003eYokogawa AFV10D-S41101 Duplexed Field Control Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV10D-S41101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAFV10D\u003c\/strong\u003e Duplexed Field Control Unit, operates as a dedicated hardware component for executing regulatory and sequence control logic within CENTUM VP Distributed Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8 kg (fully populated with dual CPU and dual power modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 5.1 cm x 20.3 cm x 14.6 cm per sub-card; standard 19-inch rack chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessorType\u003c\/td\u003e\n\u003ctd\u003eVR5432 RISC, 133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMainMemory\u003c\/td\u003e\n\u003ctd\u003e32 MB ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlScanPeriod\u003c\/td\u003e\n\u003ctd\u003eConfigurable: 50 ms \/ 100 ms \/ 200 ms \/ 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerSupply\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC, 50\/60 Hz, 200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup\u003c\/td\u003e\n\u003ctd\u003e72-hour battery memory retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworkProtocol\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP, 1 Gbps \/ 100 Mbps Full Duplex auto-negotiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003eDual-redundant RJ45 (CAT5e or better)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaxIONodes\u003c\/td\u003e\n\u003ctd\u003e14 (9 local ESB, 5 remote ER)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatusContacts\u003c\/td\u003e\n\u003ctd\u003e2 terminals, NC\/C, 30 V DC, 0.3 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AFV10D-S41101 implements channel-to-channel isolation to prevent data interference between adjacent I\/O channels. Cold junction compensation (CJc) is applied across temperature sensors to maintain analog signal integrity. The module supports 4-20 mA HART loop protocol for direct communication with field instruments and can interface with FOUNDATION Fieldbus and Profibus PA networks. Failover between duplexed CPUs occurs in milliseconds, ensuring uninterrupted control execution and continuous data logging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the failover time between redundant CPUs?\u003c\/strong\u003e\u003cbr\u003eA: Redundant CPU failover occurs within milliseconds without disrupting process control loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AFV10D-S41101 handle hot-swappable I\/O modules?\u003c\/strong\u003e\u003cbr\u003eA: Local ESB Bus Node modules can be replaced or added with the FCU powered, provided the ESB coupler is properly installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is firmware upgrade compatible with both active and standby CPUs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, firmware can be updated sequentially on standby first to maintain control continuity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMount the unit in a standard 19-inch rack using 8 x M5 screws with insulation bushes.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum of 100 mm clearance around the chassis for airflow.\u003c\/li\u003e\n\u003cli\u003eConnect redundant Vnet\/IP cables using CAT5e or higher-rated UTP and ensure proper termination at the switch.\u003c\/li\u003e\n\u003cli\u003eGround the chassis to plant earth; avoid sharing the same conductor with high-power equipment to prevent interference.\u003c\/li\u003e\n\u003cli\u003eInstall ESB Bus Coupler Module in Slot 7 or 8 for local I\/O node connectivity.\u003c\/li\u003e\n\u003cli\u003eObserve input voltage tolerance (85–132 V AC) to prevent overvoltage or undervoltage faults.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44182523215960,"sku":"AFV10D-S41101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AFV10D-S41101.jpg?v=1780552540","url":"https:\/\/www.industriaxplc.com\/ar\/products\/yokogawa-afv10d-s41101-duplexed-field-control-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}