{"product_id":"yokogawa-a2sam505-h000-s1-current-voltage-output-adaptor","title":"Yokogawa A2SAM505-H000 S1 Current\/Voltage Output Adaptor","description":"\u003ch2\u003eYokogawa A2SAM505-H000 S1 Current\/Voltage Output Adaptor\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog current and voltage signal generation in the CENTUM VP N-IO network, the \u003cstrong\u003eYokogawa A2SAM505-H000 S1\u003c\/strong\u003e (\u003cstrong\u003eA2SAM505\u003c\/strong\u003e Current\/Voltage Output Adaptor) provides direct physical and electrical execution of isolated analog output functions. The adaptor interfaces with N-IO modules and converts internal control commands into configurable 0-10 VDC or 4-20 mA output signals while maintaining galvanic isolation between field circuits and the control system.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Element\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA2SAM505\u003c\/td\u003e\n\u003ctd\u003eCurrent\/Voltage Output Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-H\u003c\/td\u003e\n\u003ctd\u003eStandard type, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e000\u003c\/td\u003e\n\u003ctd\u003eBasic specification code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS1\u003c\/td\u003e\n\u003ctd\u003eHardware style revision 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA2SAM505-H000 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCurrent\/Voltage Output Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP N-IO System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal (Voltage)\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal (Current)\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Output Range\u003c\/td\u003e\n\u003ctd\u003e-0.3 to 10.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Output Range\u003c\/td\u003e\n\u003ctd\u003e1-23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance (Voltage)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance (Current)\u003c\/td\u003e\n\u003ctd\u003e0-750 Ohm at 20 mA; 0-600 Ohm at 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limitation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Current Limit\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Loop Detection\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.65 mA trigger threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e2 ms adaptor; up to 10 ms through N-IO module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Output to System)\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute; 42 VDC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Adjacent Adaptors)\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 1 minute; 42 VDC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (24 VDC Supply)\u003c\/td\u003e\n\u003ctd\u003e38 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (5 VDC Internal Supply)\u003c\/td\u003e\n\u003ctd\u003e10 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 13.0 x 1.5 x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eTypical 0.072 kg; \u0026lt;= 0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eA2BN3D Adaptor Base Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and HART Output Integration\u003c\/h3\u003e\n\u003cp\u003eThe A2SAM505 supports isolated analog output operation with channel-level galvanic separation between field-side wiring and the N-IO control domain. For current output operation, the adaptor supports HART 7 communication superimposed on the 4-20 mA loop, allowing simultaneous analog signal transmission and digital device communication. Open-loop monitoring is available during current output operation and activates when loop current falls to 0.65 mA or below.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the A2SAM505 require hardware jumpers to change between voltage and current output modes?\u003c\/strong\u003e\u003cbr\u003eA: No. Output mode selection between 0-10 VDC and 4-20 mA is performed through system software configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the adaptor be replaced while the N-IO system remains energized?\u003c\/strong\u003e\u003cbr\u003eA: The module is designed for hot-swappable operation when installed on the designated A2BN3D adaptor base plate and used according to Yokogawa maintenance procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output load limitations apply to current mode operation?\u003c\/strong\u003e\u003cbr\u003eA: The adaptor supports loads up to 750 Ohm at 20 mA output and up to 600 Ohm at 23 mA output while maintaining specified operating limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the adaptor only on a compatible A2BN3D adaptor base plate.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity before energizing output circuits.\u003c\/li\u003e\n\u003cli\u003eSeparate analog output cabling from high-energy power conductors to reduce conducted interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to plant grounding standards and DCS cabinet grounding practices.\u003c\/li\u003e\n\u003cli\u003eConfirm field device loop resistance remains within the specified operating range before commissioning.\u003c\/li\u003e\n\u003cli\u003ePerform output verification using calibrated measurement equipment after installation or replacement.\u003c\/li\u003e\n\u003cli\u003eWhen HART communication is required, ensure loop components and field devices support HART-compatible operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44175271231576,"sku":"A2SAM505-H000 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/A2SAM505-H000S1-2.jpg?v=1780451742","url":"https:\/\/www.industriaxplc.com\/ar\/products\/yokogawa-a2sam505-h000-s1-current-voltage-output-adaptor","provider":"IndustriaX Limited","version":"1.0","type":"link"}