{"product_id":"ycb301-c020-yokogawa-esb-bus-cable-36-36-pins","title":"YCB301-C020 | Yokogawa | ESB Bus Cable (36-36 pins)","description":"\u003ch2\u003eYokogawa YCB301-C020 ESB Bus Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa YCB301-C020\u003c\/strong\u003e serves as the primary \u003cstrong\u003eYCB301\u003c\/strong\u003e ESB Bus Cable utilized to execute high-speed Extended System Bus communication between FCU and ESB Bus node units across CENTUM VP and CENTUM CS 3000 platforms. The \u003cstrong\u003eYCB301-C020\u003c\/strong\u003e incorporates a 36-pin to 36-pin connection structure and a fixed cable length of 20 cm for short-distance cabinet interconnections.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eYCB301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code\u003c\/td\u003e\n\u003ctd\u003eC020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003e36-pin to 36-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eExtended System Bus (ESB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Application\u003c\/td\u003e\n\u003ctd\u003eFCU-to-Node Unit or Node-to-Node Interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB301-C020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable, no power consumption specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Communication Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e36-pin to 36-pin high-density connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Type\u003c\/td\u003e\n\u003ctd\u003eExtended System Bus (ESB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e128 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant architecture capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eEMI\/RFI shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Application\u003c\/td\u003e\n\u003ctd\u003eInternal cabinet and rack interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Communication Paths\u003c\/h3\u003e\n\u003cp\u003eWithin Yokogawa FIO system architectures, ESB communication links operate independently from analog process signal paths such as 4-20 mA loops. The YCB301-C020 functions exclusively as a digital communication medium between FCUs and ESB node units. Proper connector engagement, shielding continuity, and controlled cable routing contribute to signal integrity within densely populated DCS cabinets where multiple communication channels operate in parallel.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the YCB301-C020 require external power for operation?\u003c\/strong\u003e\u003cbr\u003eA: No. The cable is a passive communication component and does not consume operating power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the YCB301-C020 be used between non-adjacent cabinet sections?\u003c\/strong\u003e\u003cbr\u003eA: The specified cable length is 20 cm. Installation suitability depends on physical spacing and routing requirements between connected devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the cable support redundant ESB configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The cable is designed for use within ESB architectures that support dual-redundant communication arrangements when installed according to system requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify connector orientation before insertion to prevent pin damage.\u003c\/li\u003e\n\u003cli\u003eUse the cable only where the 20 cm length permits installation without tensile stress.\u003c\/li\u003e\n\u003cli\u003eMaintain shielding continuity according to cabinet grounding practices.\u003c\/li\u003e\n\u003cli\u003eAvoid routing the cable adjacent to high-current power conductors or switching devices where electromagnetic interference may be present.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the manufacturer's recommended bend radius during installation.\u003c\/li\u003e\n\u003cli\u003eConfirm latch engagement on both 36-pin connectors after installation.\u003c\/li\u003e\n\u003cli\u003ePerform communication diagnostics following cabinet assembly and system commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44165676925016,"sku":"YCB301-C020","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/YCB301-C020.jpg?v=1780363804","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ycb301-c020-yokogawa-esb-bus-cable-36-36-pins","provider":"IndustriaX Limited","version":"1.0","type":"link"}