{"product_id":"woodward-8440-2050-easygen-3200-5-genset-controller","title":"Woodward 8440-2050 EasyGen-3200-5 Genset Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Woodward 8440-2050 EasyGen-3200-5 is a sophisticated genset control and protection unit engineered for complex power management applications. It serves as a central hub for engine-generator control, offering advanced synchronization, load sharing, and protection logic. This controller is specifically designed for critical power environments, including marine vessels, large-scale data centers, and oil and gas infrastructure, where reliability and precise power distribution are paramount.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Synchronization:\u003c\/strong\u003e Supports complex power management for up to 32 gensets in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e Features dual CAN bus ports for J1939 engine ECU integration and RS-485 for Modbus RTU communication with SCADA\/BMS systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e Housed in a durable enclosure suitable for front-panel mounting in high-vibration environments such as engine skids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile I\/O:\u003c\/strong\u003e Equipped with 10 configurable discrete inputs, 12 configurable relay outputs, and flexible analog input\/output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Sensing:\u003c\/strong\u003e Provides accurate voltage and current monitoring for reliable system diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe EasyGen-3200-5 is ideal for emergency standby power, cogeneration systems, and critical power distribution. Its robust architecture makes it suitable for deployment in harsh industrial settings, including marine power plants, data center backup systems, and oil refinery power management.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8440-2050 EasyGen-3200-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Supply\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC (8 to 40 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 17 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Sensing\u003c\/td\u003e\n\u003ctd\u003e100 VAC to 480 VAC (True RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Sensing\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A (Secondary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e10 Configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e12 Configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e0-2500 Ohm \/ 0-20 mA \/ 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V \/ +\/- 20 mA \/ PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the unit is securely mounted in a front-panel configuration using the provided hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Verify that the supply voltage is within the 8 to 40 VDC range before connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cables for communication lines (CAN\/RS-485) to minimize EMI interference. Ensure proper grounding of the controller chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Always disconnect power before performing any wiring or maintenance on the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure adequate ventilation around the unit to maintain operating temperatures within the specified -20 to 70 deg C range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the EasyGen-3200-5 compatible with existing SCADA systems?\u003c\/h3\u003e\u003cp\u003eYes, the unit supports Modbus RTU protocols via RS-485, allowing for seamless integration into most standard SCADA and building management systems.\u003c\/p\u003e\u003ch3\u003eCan this controller manage multiple generators?\u003c\/h3\u003e\u003cp\u003eYes, the EasyGen-3200-5 is designed to handle the synchronization and load sharing of up to 32 gensets in a single system.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":44648129134680,"sku":"8440-2050 EASYGEN-3200-5","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_b99ab2d1-a7ea-47b2-829d-cfaab8c1d3c3.jpg?v=1787505918","url":"https:\/\/www.industriaxplc.com\/ar\/products\/woodward-8440-2050-easygen-3200-5-genset-controller","provider":"IndustriaX Limited","version":"1.0","type":"link"}