{"product_id":"tk801v006-3bsc950089r2-abb-advant-ocs-800xa-modulebus-extension-cable","title":"TK801V006 3BSC950089R2 ABB Advant OCS 800xA ModuleBus Extension Cable","description":"\u003ch2\u003eABB TK801V006 3BSC950089R2 ModuleBus Extension Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for ModuleBus physical extension in S800 I\/O systems, the \u003cstrong\u003eABB TK801V006 3BSC950089R2\u003c\/strong\u003e (\u003cstrong\u003eTK801V006\u003c\/strong\u003e ModuleBus Extension Cable) provides direct electrical connection between TB805\/TB845 or TB806\/TB846 terminal units to extend I\/O module installation across separate DIN rails.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK801V006 3BSC950089R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModuleBus Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSC950089R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 x 2.5 x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable connection, no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Platform\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD SUB 25 male\/female connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eShielded extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eModuleBus signal extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate Support\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Units\u003c\/td\u003e\n\u003ctd\u003eTB805\/TB845 and TB806\/TB846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 ModuleBus Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TK801V006 extends the electrical ModuleBus connection while maintaining communication between S800 I\/O modules installed on different DIN rails. The cable uses a shielded D SUB 25 interface to transfer ModuleBus signals between terminal units.\u003c\/p\u003e\n\u003cp\u003eFurthermore, ABB S800 architecture uses a dedicated backplane-style communication structure for I\/O module data exchange. The TK801V006 supports ModuleBus extension requirements without adding active electronic conversion components or external communication nodes.\u003c\/p\u003e\n\u003cp\u003eThe cable design supports physical separation of I\/O assemblies while keeping the same ModuleBus network segment. Therefore, system designers can distribute S800 I\/O modules according to cabinet layout and installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the main function of the ABB TK801V006 cable?\u003cbr\u003eA: The TK801V006 extends the electrical ModuleBus connection between compatible ABB S800 terminal units, allowing I\/O modules to be mounted on different DIN rails.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK801V006 require an external power supply?\u003cbr\u003eA: No. The TK801V006 is a passive shielded extension cable and does not require independent power input.\u003c\/p\u003e\n\u003cp\u003eQ: Which terminal units are compatible with the TK801V006?\u003cbr\u003eA: The cable is designed for use with ABB TB805\/TB845 and TB806\/TB846 terminal units within S800 I\/O installations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TK801V006 between compatible ModuleBus terminal units according to ABB S800 system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eVerify that the D SUB 25 male and female connectors match the corresponding terminal unit interfaces before installation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing to avoid mechanical stress, excessive bending, and interference from high-power electrical conductors.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shield according to the cabinet grounding design to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eConfirm ModuleBus communication after installation through the automation system engineering tools.\u003c\/li\u003e\n\u003cli\u003eAvoid installing the extension cable near strong electromagnetic interference sources without appropriate shielding measures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619062968408,"sku":"TK801V006 3BSC950089R2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TK801V0063BSC950089R2-3.jpg?v=1787037205","url":"https:\/\/www.industriaxplc.com\/ar\/products\/tk801v006-3bsc950089r2-abb-advant-ocs-800xa-modulebus-extension-cable","provider":"IndustriaX Limited","version":"1.0","type":"link"}