{"product_id":"thrust-position-monitor-3300-35-12-01-01-00-00-bently-nevada","title":"Thrust Position Monitor 3300\/35-12-01-01-00-00 Bently Nevada","description":"\u003ch1\u003eBently Nevada 3300\/35-12-01-01-00-00 Six-Channel Radial Vibration \/ Thrust Position Monitor\u003c\/h1\u003e\n\u003cp\u003eConfigured for shaft radial vibration and thrust position measurement in the Bently Nevada 3300 monitoring system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/35-12-01-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(base model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/35\u003c\/strong\u003e) provides direct signal conditioning and relay drive execution for machinery protection loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eOption Code\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eFunction\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3300\/35\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSix-Channel Radial Vibration \/ Thrust Position Monitor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e-12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eChannel Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo Thrust channels, Four Radial Vibration channels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e-01\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFull-Scale Range Option\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard full-scale ranges for radial and thrust measurements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e-01\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAgency Approval Option\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCSA \/ NRTL \/ C (Class I, Div 2, Groups A–D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e-00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSafety Barrier Option\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e-00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eModbus\/Comms Option\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eParameter\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBently Nevada\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOrigin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnited States\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.13 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e241 mm x 50 mm x 290 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating Temp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 degC to +65 degC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Consumption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7.5 W from 3300 backplane supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput Impedance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 kOhm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBuffered Output Impedance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRecorder Outputs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4-20 mA or 1-5 Vdc (jumper selectable)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAlarm Setpoints\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0–100% of full scale, Alert and Danger independently adjustable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAlarm Delay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1, 1, 3, or 6 sec (jumper selectable)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative Humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUp to 95%, non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe monitor interfaces directly with Bently Nevada eddy-current proximity transducers, requiring precise probe scaling to match target material properties. Calibration must ensure that gap voltage targets remain near -10 VDC under static shaft conditions to maintain linear displacement measurement and minimize rotor dynamics errors. Cross-talk suppression is implemented through shielded twisted-pair wiring and isolated grounding points at the rack frame.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 3300\/35 be hot-swapped in a live rack?\u003c\/p\u003e\n\u003cp\u003eA: No. The module must be installed or removed only when the rack power is disconnected to prevent backplane transient damage.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cable length between probe and monitor?\u003c\/p\u003e\n\u003cp\u003eA: For standard 3300 5 mm and 8 mm probes, total extension cable length should not exceed 305 m to preserve signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: Does the -00 safety barrier option affect recorder output performance?\u003c\/p\u003e\n\u003cp\u003eA: No. The absence of internal safety barriers removes intrinsic safety isolation but does not alter electrical output characteristics.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module in a single 3300 rack slot with proper EMC clearance from high-power conductors. Use continuous shield termination at both ends of transducer cables, bonded to rack ground. Verify gap voltage before energizing the system to ensure mechanical clearance compliance. Route signal wiring separately from power conductors to reduce electromagnetic interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44247983718488,"sku":"3300\/35-12-01-01-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330035-12-01-01-00-00-3.jpg?v=1781661785","url":"https:\/\/www.industriaxplc.com\/ar\/products\/thrust-position-monitor-3300-35-12-01-01-00-00-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}