{"product_id":"system-interconnection-cable-honeywell-fs-sicc-001-l8-in","title":"System Interconnection Cable | Honeywell FS-SICC-001\/L8-IN","description":"\u003ch2\u003eHoneywell FS-SICC-001\/L8-IN System Interconnection Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-SICC-001\/L8-IN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-SICC-0001\/L8\u003c\/strong\u003e System Interconnection Cable, operates as a dedicated hardware component for signal connection between controller modules and Field Termination Assemblies within Honeywell Safety Manager and FTAS systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SICC-001\/L8-IN (FS-SICC-0001\/L8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSystem Interconnection Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FTAS Field Termination Assembly Slim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003eTinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eTypically 18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eAluminum Mylar Shield with Drain Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003eHigh-density Polyethylene \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eFactory Pre-terminated \/ Ferrule Terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.0 kg - 1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly, no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Function\u003c\/td\u003e\n\u003ctd\u003eController-to-FTA system interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Interface and Cable Construction\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FS-SICC-001\/L8-IN provides a direct electrical connection path between Safety Manager hardware and FTAS termination assemblies. Moreover, the cable construction uses shielded conductors to reduce electromagnetic interference and radio frequency interference during signal transmission.\u003c\/p\u003e\n\u003cp\u003eThe cable assembly uses tinned copper conductors to improve oxidation resistance in industrial environments. In addition, the pre-terminated configuration reduces field wiring operations and maintains consistent connection quality between system components.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell process control architectures, the cable supports physical signal routing associated with DCS and safety system interfaces. Therefore, installation practices must maintain proper cable separation, grounding, and shielding continuity to preserve signal characteristics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FS-SICC-001\/L8-IN require an external power supply?\u003cbr\u003eA: No. The FS-SICC-001\/L8-IN is a passive interconnection cable assembly and does not consume external electrical power.\u003c\/p\u003e\n\u003cp\u003eQ: What shielding method does the cable use for industrial signal protection?\u003cbr\u003eA: The cable uses an aluminum Mylar shield with a drain wire to reduce electromagnetic interference effects on transmitted signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can the cable length be modified during field installation?\u003cbr\u003eA: Field modification is not recommended because the cable uses factory-terminated connections. Any alteration may affect connector integrity and signal interface performance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the cable part number before installation to ensure compatibility with the intended Honeywell Safety Manager and FTAS hardware interface.\u003c\/li\u003e\n\u003cli\u003eInstall the cable using the specified termination orientation and avoid unnecessary mechanical stress on connectors.\u003c\/li\u003e\n\u003cli\u003eMaintain separation from high-voltage power cables and strong electromagnetic sources to reduce induced noise.\u003c\/li\u003e\n\u003cli\u003eConnect the shield drain according to the system grounding design and maintain continuous shielding where required.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bending, excessive pulling force, or routing methods that may damage the insulation or termination points.\u003c\/li\u003e\n\u003cli\u003eInspect connectors before commissioning and confirm that all mating interfaces are fully seated.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44381990682712,"sku":"FS-SICC-001\/L8-IN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FS-SICC-001L8-IN-3.jpg?v=1784098835","url":"https:\/\/www.industriaxplc.com\/ar\/products\/system-interconnection-cable-honeywell-fs-sicc-001-l8-in","provider":"IndustriaX Limited","version":"1.0","type":"link"}