{"product_id":"schneider-electric-tsxdey32d2-modicon-premium-discrete-input-module","title":"Schneider Electric TSXDEY32D2 Modicon Premium Discrete Input Module","description":"\u003ch2\u003eSchneider Electric TSXDEY32D2 Modicon Premium Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric TSXDEY32D2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSXDEY32D2\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for 24 VDC digital signal acquisition within the Modicon Premium Automation Platform. It provides 32 isolated current-sink input channels for direct field signal interfacing through the PLC backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDEY32D2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated current-sink digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e19 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e3.5 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic State 1 Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic State 1 Current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic State 0 Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic State 0 Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e6300 Ohm at logic state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e4 ms, \u0026lt;= 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MOhm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1 W + 0.1 W x active channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eHE-10 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e135 mA at 5 VDC; 160 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, ABS, GL, BV, RINA, RMRS, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Backplane Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TSXDEY32D2 exchanges discrete input data with the Modicon Premium backplane through the platform's internal bus architecture. Input status is cyclically transferred to the processor without requiring external communication configuration. Backplane current loading should be included during rack power budget calculations, particularly when multiple high-density I\/O modules are installed in the same chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TSXDEY32D2 support hot replacement while the PLC remains energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied technical data does not specify hot-swap capability. Module replacement should follow the maintenance procedure defined for the installed Modicon Premium system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of field devices can be connected to the inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for 24 VDC positive current-sink digital signals conforming to EN\/IEC 61131-2 Type 1 input characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is module power consumption determined?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Internal power dissipation is specified as \u003cstrong\u003e1 W + 0.1 W multiplied by the number of active input channels\u003c\/strong\u003e. Backplane current consumption is 135 mA at 5 VDC and 160 mA at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the PLC rack power budget before installing multiple high-density input modules.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring using the specified HE-10 connector with correct pin assignment.\u003c\/li\u003e\n\u003cli\u003eRoute digital input cables separately from high-power AC conductors to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shielding according to the plant grounding practice and avoid multiple shield grounding points unless required by the control system design.\u003c\/li\u003e\n\u003cli\u003eConfirm field voltage remains within the specified 19 to 30 VDC sensor supply range before commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain the enclosure environment within the specified IP20 operating conditions and ambient temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44278215180376,"sku":"TSXDEY32D2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXDEY32D2-3.jpg?v=1782436711","url":"https:\/\/www.industriaxplc.com\/ar\/products\/schneider-electric-tsxdey32d2-modicon-premium-discrete-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}