{"product_id":"schneider-electric-bmxddo6402k-modicon-x80-discrete-output-module","title":"Schneider Electric BMXDDO6402K Modicon X80 Discrete Output Module","description":"\u003ch1\u003eSchneider Electric BMXDDO6402K Modicon X80 Discrete Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for high-density digital switching of field actuators in Modicon X80 I\/O architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric BMXDDO6402K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eBMXDDO6402K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete Output Module) provides direct physical\/electrical execution of 24 VDC positive logic output commands across 64-channel backplane-controlled points.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eBMXDDO6402K is a single-order discrete output module designation within the Modicon X80 family.\u003cbr\u003eNo validated manufacturer-published suffix segmentation beyond base functional code is available in the provided dataset.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDDO6402K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e160 mA at 3.3 VDC (backplane supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSolid-state discrete output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e19...30 VDC (nominal 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Module Current\u003c\/td\u003e\n\u003ctd\u003e6.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParalleling\u003c\/td\u003e\n\u003ctd\u003eUp to 3 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit, overload, overvoltage, reverse polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Communication \u0026amp; Deterministic I\/O Handling (Modicon X80 Platform Integration)\u003c\/h3\u003e\n\u003cp\u003eThe module operates as a backplane-driven discrete execution node within the Modicon X80 rack architecture. Output state transitions are synchronized through deterministic internal bus scanning, ensuring consistent update alignment across distributed rack modules. Channel update latency is governed by internal scan scheduling rather than field-side feedback loops. Electrical isolation and per-channel protection stages reduce cross-channel propagation effects under inductive switching conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can outputs be paralleled for higher current drive?\u003cbr\u003eA: Yes. Paralleling is supported up to 3 outputs, subject to shared load distribution and thermal dissipation constraints.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide per-channel short-circuit shutdown?\u003cbr\u003eA: Yes. Each channel integrates electronic current limiting and fault isolation behavior using internal protection circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: What is the response behavior under overload conditions?\u003cbr\u003eA: The output stage transitions into current-limited operation with protective cutoff behavior when thresholds are exceeded.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module shall be installed only in a compatible Modicon X80 rack with verified backplane alignment. Ensure correct seating to maintain signal integrity across the internal bus connector. Field wiring must comply with 24 VDC separation rules, maintaining segregation between power conductors and low-level control wiring.\u003c\/p\u003e\n\u003cp\u003eInductive loads require external suppression elements to limit voltage transients during switching. Channel grouping for high duty-cycle loads should consider cumulative thermal loading across adjacent outputs. Shielding and grounding should be terminated according to cabinet-level equipotential bonding practice to reduce noise coupling into adjacent I\/O modules.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44242241290328,"sku":"BMXDDO6402K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXDDO6402K-3.jpg?v=1781514627","url":"https:\/\/www.industriaxplc.com\/ar\/products\/schneider-electric-bmxddo6402k-modicon-x80-discrete-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}