{"product_id":"relay-discrete-output-module-schneider-electric-140drc83000","title":"Relay Discrete Output Module  Schneider Electric 140DRC83000","description":"\u003ch2\u003eSchneider Electric 140DRC83000 Modicon Quantum Relay Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 140DRC83000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e140DRC83000\u003c\/strong\u003e Relay Discrete Output Module, operates as a dedicated hardware component for relay-based field output switching within the Modicon Quantum automation platform.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies a single catalog number only. No official suffix or ordering code breakdown is specified.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140DRC83000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Discrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e8 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003e1 NO\/NC, Form C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e0.5 output word\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e20 - 250 VAC, 30 - 150 VDC, 5 - 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e5 A resistive at 250 VAC or 30 VDC (60 degC), 3 A general load, 2 A tungsten load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 20 A for 10 ms (capacitive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e30 Hz resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e1250 VA resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 ms OFF to ON, \u0026lt;= 20 ms ON to OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e10,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003eUp to 200,000 cycles depending on load type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eInternal 275 V varistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Isolation\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms AC and 2500 VDC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e560 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.75 W + (0.5 W x active output points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eActive LED, Fault LED, 8 output status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 - 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 - 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eABS, DNV, FM Class 1 Div 2, GL, GOST, RINA, RMRS, C-Tick, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 142, UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and I\/O Integration\u003c\/h3\u003e\n\u003cp\u003eAs a member of the Modicon Quantum platform, the module exchanges output data through the Quantum backplane while occupying one standard module slot. Output addressing requires 0.5 output word for eight relay channels. The module reports operational status using dedicated Active, Fault, and per-channel output LEDs. Bus current consumption is specified as 560 mA and should be included during rack power budget calculations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module provide electrical isolation between relay channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The relay channels provide 1780 Vrms AC isolation for 1 minute between channels, and the same isolation level between the channels and the backplane bus. Bus isolation is additionally rated at 2500 VDC for 1 minute.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can inductive loads be connected directly to the relay outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Inductive loads are supported within the published switching specifications. The integrated 275 V varistor provides output overvoltage suppression during switching events.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be considered when calculating rack power requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Include the module bus current requirement of 560 mA together with the power dissipation specification of 2.75 W plus 0.5 W for each energized output point when evaluating enclosure thermal loading and power supply capacity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the module catalog number before installation to ensure compatibility with the Modicon Quantum rack.\u003c\/li\u003e\n\u003cli\u003eDe-energize the system before inserting or removing the module unless the controller documentation explicitly permits the maintenance procedure.\u003c\/li\u003e\n\u003cli\u003eSeparate relay output wiring from low-level analog and communication cables to reduce conducted electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to the specified voltage and current ratings for each relay contact.\u003c\/li\u003e\n\u003cli\u003eMaintain protective earth grounding for the control cabinet and terminate cable shields in accordance with the site's grounding practice.\u003c\/li\u003e\n\u003cli\u003eConfirm the total backplane current and enclosure thermal limits before commissioning additional I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44290472902744,"sku":"140DRC83000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/140DRC83000-3.jpg?v=1782717153","url":"https:\/\/www.industriaxplc.com\/ar\/products\/relay-discrete-output-module-schneider-electric-140drc83000","provider":"IndustriaX Limited","version":"1.0","type":"link"}